59
Flow Control
Set this option to select Flow Control for console redirection.
The settings for this value are
None, Hardware RTS/CTS
.
VT-UTF8 Combo Key Support
Enabled VT-UTF8 combination key support for ANSI/VT100 terminals..
Set this value to
Enable/Disable.
Recorder Mode
Enabled this mode, only text will be sent. This is to capture terminal data.
Set this value to
Enable/Disable.
Resolution 100x31
Set this option to extended terminal resolution. Set this value to
Enable/Disable.
Legacy OS Redirection
On Legacy OS, the number of rows and columns supported redirection.
Set this value to
80x24 / 80x25.
Putty Key Pad
Select FunctionKey and KeyPad on Putty.
Set this value to
VT100 / LINUX/XTERMR6/SCO/ESCN/VT400.
Serial Port for Out-of-Band Management/Windows Emergency
Management Services(EMS)
The following functions control the presence and content of the ACPI serial port
redirection table (SPCR). This table is mainly used by the Windows server variants to
provide Windows Emergency Management Services (EMS). This functionality is totally
independent from serial redirection of other console output. OoB Management or EMS
makes it possible to control selected components of (Windows) servers, even when a
server is not connected to the network or the network is not available. In short: EMS
allows for remote management of a Windows Server OS through a serial port
Out-of-Band Mgmt Port
Set this option to select which serial port will be used for EMS.
Set this value to
COM1 / COM2 / COM3