Connectors and Jumpers 

4.2.9. 

Feature Connector (FC1) 

2x14-pin 2.0 pitch standard wafer connector 

The feature connector provides Case Open, I2C, SMBus, and GPIO (10pin). 

Signal  

Description 

TEMPS 

Analogue temp sensor, connect to analog input of BMC 

EXT_BAT 

Connect to RTC power  

CASE_OPEN#  Any time case open occurs, system will notice/show case 

open alert in POST during the next boot. 

I2CC / I2CD 

Connect to BMC (I2C Master) 

I2C SEMA 

 

Pin #  Signal 

IOH/IOL  Pull U/D  Type

Note

Pin #

Signal 

Type

IOH/IOL 

Pull U/D  Note

1  CASE_OPEN# 

PU 

2M I   

2  SMBC  OT /4mA  PU 2.2K  

SB3V3 

3 GND 

PWR   4 SMBD OT 

/4mA PU 2.2K  

SB3V3 

5 TEMPS 

I  2 6 I2CC  OT 

PU 2.2K  
3V3 

7 EXT_BAT - 

PWR  8 I2CD OT 

PU 2.2K  
3V3 

SB3V3 - - PWR  

10 

5V PWR - -  

11 

GND  - - PWR  

12 

GND 

PWR - -  

13 GPIO0 

PU 10K 
SB3V3 

IOT  

14  GPIO1  IOT  

PU 10K 
SB3V3 

 

15 GPIO2 

PU 10K 
SB3V3 

IOT  

16  GPIO3  IOT  

PU 10K 
SB3V3 

 

17 GPIO4 

PU 10K 
SB3V3 

IOT  

18  GPIO5  IOT  

PU 10K 
SB3V3 

 

19 GPIO6 

PU 10K 
SB3V3 

IOT  

20  GPIO7  IOT  

PU 10K 
SB3V3 

 

21 

N/C 

- - - 

 

22 

N/C 

- -  

23 GND 

 

PWR   24 SUS_S3# O  25/25mA 

 

25 12V 

PWR   26 SUS_S4# O  25/25mA 

 

27 

PWR_OK 

25/25mA O 

 

28 

SUS_S5# O 

25/25mA - 

 

 

Note 1:

 Pull-up to +3V3Dual (+3V3 or SB3V3). 

Note 2:

 Input to SEMA. 

 

1

              

2

Содержание AmITX-RZ-G

Страница 1: ...Leading EDGE COMPUTING AmITX RZ G User s Manual Mini ITX Embedded Motherboard with AMD Embedded V1000 R1000 Series APU Manual Rev 1 0 Revision Date May 18 2020 Part Number 50 1X016 1000 ...

Страница 2: ... protection is a top priority for ADLINK We have enforced measures to ensure that our products manufacturing processes components and raw materials have as little impact on the environment as possible When products are at their end of life our customers are encouraged to dispose of them in accordance with the product disposal and or recovery programs prescribed by their nation or company Battery L...

Страница 3: ...Power Specifications 5 2 12 Power Consumption 5 2 13 Temperatures 7 2 14 Environmental 7 2 15 Operating Systems 7 2 16 Functional Block Diagram 8 3 Mechanical Layout 9 3 1 Rear I O Connectors 9 3 2 Component Side Connectors 10 3 3 Mechanical Dimensions 11 3 4 Thermal Solutions 12 4 Connectors and Jumpers 13 4 1 Rear IO Connectors 13 4 2 Internal Connectors 15 4 3 Jumper and Switch Settings 25 4 4 ...

Страница 4: ...7 4 PCI Configuration Space Map 38 7 5 PCI Interrupt Routing Map 39 7 6 SMBus Slave Address 39 8 BIOS Setup 41 8 1 Menu Structure 41 8 2 Main 42 8 3 Advanced 44 8 4 Security 58 8 5 Boot 58 8 6 Save Exit 61 Safety Instructions 62 Getting Service 63 ...

Страница 5: ...k Diagram 8 Figure 2 AmITX RZ G with V1000 Series Processor Rear I O 9 Figure 2 AmITX RZ G with R1000 Series Processor Rear I O 9 Figure 3 AmITX RZ G Component Side Connectors 10 Figure 4 AmITX RZ G Mechanical Dimensions 11 Figure 5 AmITX RZ G Jumper and Switch Locations 25 ...

Страница 6: ...d Voltage Monitor 31 Table 4 SEMA BMC Status 32 Table 5 SEMA Exception Codes 33 Table 6 SEMA BMC Flags 33 Table 7 System Memory Map 35 Table 8 I O Map 35 Table 9 IRQ Lines PIC Mode 36 Table 10 IRQ Lines APIC Mode 37 Table 11 PCI Configuration Space Map 38 Table 12 PCI Interrupt Routing Map 39 Table 13 SMBus Slave Address 39 ...

Страница 7: ...atures four DisplayPorts dual Gigabit Ethernet port USB 3 0 ports USB 2 0 ports SATA 6 Gb s ports and High Definition Audio with 7 1 channels Support is provided for one PCIe x16 one PCIe x1 one Mini PCIe slot and one M 2 M Key socket A feature connector provides access to GPIO SMBus and I2C signals The board is equipped with dual SPI AMI EFI BIOS sockets supporting embedded features such as hardw...

Страница 8: ...2 Introduction This page intentionally left blank ...

Страница 9: ...rs 4x DisplayPort R1000 processors 3x DisplayPort Ethernet GbE RJ 45 V1000 processors 2x GbE R1000 processors 1x GbE USB 4x USB 3 0 4x USB 2 0 Audio 7 1 channel audio via 5 jacks and S PDIF output on rear I O 2 3 Internal Headers and Connectors PCI Express Slots 1x PCIe x16 Gen3 slot PCIe x8 signal 1x PCIe x1 Gen3 slot PCIe 3 0 1x full size Mini PCIe slot for MSATA device V1000 processors only USB...

Страница 10: ...ebug LEDs 2 7 Video Graphics Core Vega GPU with up to 11 Compute Units Display Interface Support DisplayPort with resolution up to 4096 x 2160 60Hz V1000 processors 4x DisplayPort R1000 processors 3x DisplayPort 2 8 Audio Audio Codec Realtek ALC892 Interfaces 7 1 channel audio via 5 jacks and S PDIF output on rear I O 7 1 channel audio signals and S PDIF output via internal header 2 9 LAN Controll...

Страница 11: ...EMP BIOS 1 01 10 1V7 OS Windows 10 Windows Idle mode Enable PSS Support wait 60s no fan turn on 3 3A A 0 09 0 09 0 11 0 11 0 11 0 12 5V A 0 12 0 15 0 15 0 15 0 15 0 15 12V A 2 31 1 87 1 86 1 48 1 47 1 95 5VSB A 0 03 0 03 0 03 0 04 0 04 0 03 Power Cons W 28 77 23 64 23 58 19 073 18 95 24 7 Windows Idle mode Disable PSS Support wait 60s no fan turn on 3 3A A 0 1 0 1 0 09 0 1 0 11 0 1 5V A 0 12 0 15 ...

Страница 12: ...5 0 22 12V A 11 37 8 98 6 67 5 36 6 42 7 11 5VSB A 0 04 0 04 0 04 0 05 0 04 0 05 Power Cons W 137 8 109 12 81 4 65 77 78 35 87 09 Windows Max mode Disable PSS Support 3 3A A 0 11 0 11 0 12 0 11 0 12 1 2 5V A 0 16 0 17 0 16 0 16 0 16 0 17 12V A 11 43 9 03 6 57 5 37 6 41 6 3 5VSB A 0 04 0 05 0 04 0 05 0 04 0 05 Power Cons W 138 52 109 82 80 24 65 85 78 32 80 66 System S3 mode 3 3A A 0 0 0 0 01 0 0 5...

Страница 13: ...0 03 0 03 0 04 0 04 0 03 Power Cons W 0 15 0 15 0 15 0 2 0 2 0 39 2 13 Temperatures Standard Operating Temperature 0 C to 60 C Storage Temperature 40 C to 90 C 2 14 Environmental Humidity 40 C 95 RH non condensing Shock and Vibration IEC 60068 2 64 and IEC 60068 2 27 Vibration 1Grms 5 500Hz OP 3Grms 5 500Hz NON OP Shock 20G with 11 ms duration half sine wave operating 20G with 11 ms duration half ...

Страница 14: ...8 Specifications 2 16 Functional Block Diagram Figure 1 AmITX RZ G Functional Block Diagram Note Items in red are not supported by R1000 Series SKUs ...

Страница 15: ...al Layout 3 1 Rear I O Connectors DP USB 3 0 USB 3 0 USB 2 0 LAN Audio DP DP DP LAN Figure 2 AmITX RZ G with V1000 Series Processor Rear I O DP USB 3 0 USB 3 0 USB 2 0 LAN Audio DP DP DP Figure 3 AmITX RZ G with R1000 Series Processor Rear I O ...

Страница 16: ...TX Power Connector 10 USB 2 0 Header 2 2x SODIMM DDR4 Sockets 11 5x Serial Port Headers 3 PCIe x16 slot 12 1x CPU Fan Connector 4 PCIe x1 slot 13 2x SYS Fan Connector 5 USB 2 0 Type A Connector 14 DB 40 Debug Header 6 Mini PCIe Socket mSATA 15 SPI Header 7 M 2 Socket M key 16 Feature Connector 8 2x SATA 3 0 Connector 17 Audio Header 9 2x SATA Power Connector 18 Front Panel Header ...

Страница 17: ...AmITX RZ G Mechanical Layout 11 3 3 Mechanical Dimensions Top View Side View Dimensions mm Figure 5 AmITX RZ G Mechanical Dimensions ...

Страница 18: ...12 Mechanical Layout 3 4 Thermal Solutions AMD APU Cooler H 35mm 35W Standard Temp 0 C to 60 C P N 32 20583 1010 AMD APU Cooler H 64 4mm 54W Standard Temp 0 C to 60 C P N 32 20809 0000 A0 ...

Страница 19: ...2_P 8 Ground 9 CN_DP2_N 10 CN_DP3_P 11 Ground 12 CN_DP3_N 13 CN_CAD L 14 CN_CEC 15 CN_AUX_P 16 Ground 17 CN_AUX_N 18 DDP_HPD 19 Ground 20 P3V3 4 1 2 USB Connectors 5Vsb is supplied during power down to allow wakeup on USB device activity during S3 S4 state 1 5A for device power supply protected by a resettable 2A fuse Pin Signal 1 VCC 2 UV0 3 UV0 4 GND Pin Signal 1 USB3 0_P5VA 2 USB2_CMAN 3 USB2_C...

Страница 20: ... LAN_MDI0 3 RX LAN_MDI1 4 LAN_MDI2 5 LAN_MDI2 6 RX LAN_MDI1 7 LAN_MDI3 8 LAN_MDI3 LED Behavior Position Function Color LED State NIC State Orange 1000 Mbps Green 100 Mbps LED1 Link Speed Green Orange Off 10 Mbps On Active Connection Blinking Data Activity LED2 Link Activity Orange Off LAN link is not established 4 1 4 Audio Connectors 7 1 channel audio via 5 jacks and S PDIF output on rear I O Rea...

Страница 21: ...supports a proprietary internal ATX Power Connector ATX_PWR An adapter cable is provided for conection to a standard ATX power supply Pin Signal Pin Signal 8 P_OK 1 SB5V 9 PS_ON 2 GND 10 12V 3 GND 11 12V 4 GND 12 12V 5 GND 13 12V 6 GND 14 5V 7 3 3V ATX Adapter Cable ADLINK Part No 30 20872 1000 length 250 mm Motherboard ATX Power Connector ATX_PWR ATX Power Supply ...

Страница 22: ...iver power None 3 3V 5V Default is None See 4 3 8 SATA1 2 Power Selection SATA_PSEL1 2 on 27 for jumper settings Pin Signal 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND PWR 4 2 3 SATA Power Connector SATAPW1 2 Pin Signal 1 12V 2 GND 3 5V 4 GND 5 3 3V SATA Power Cable ADLINK Part No 30 20875 0000 length 200 mm 5 4 3 2 1 HDD SSD Power Motherboard SATA Power Connector HDD SSD Power ...

Страница 23: ...es SB5V is supplied during power down to allow wakeup on USB device activity during S3 S4 state Pin Signal Pin Signal 1 P5V_USB 2 P5V_USB 3 P9_DN_R 4 P10_DN_R 5 P9_DP_R 6 P10_DP_R 7 GND 8 GND 9 KEY 10 GND USB Cable optional USB 2 0 Header to 2x Female Type A Cable length 200mm P N 30 20874 1000 1 10 ...

Страница 24: ... OUT L 5 6 FRONT OUT R AAGND 7 8 AAGND REAR OUT L 9 10 REAR OUT R SIDE OUT L 11 12 SIDE OUT R AAGND 13 14 AAGND MIC1 L 15 16 MIC1 R AAGND 17 18 AAGND LINE1 L 19 20 LINE1 R MUTE 21 22 AAGND GND 23 24 NC SPDIF OUT 25 26 GND 4 2 6 CPU Fan and System Fan Connectors FAN_CPU1 FAN_SYS1 FAN_SYS2 Pin 3 and 4 are connected monitored and managed to the SEMA controller Pin Signal 1 GND 2 Fan Power 12V 3 Fan S...

Страница 25: ...lt RS 232 COM2 4 Support only RS 232 COM5 6 Support RS 232 ccTALK RS 232 COM1 5 Pin Signal Pin Signal 1 DCD 2 DSR 3 RxD 4 RTS 5 TxD 6 CTS 7 DTR 8 RI 9 GND 10 5V 12V RS 422 COM1 only Pin Signal Pin Signal 1 Tx 2 3 Tx 4 5 R 6 7 Rx 8 9 GND 10 5V 12V RS 485 COM1 only Pin Signal Pin Signal 1 Tx Rx 2 3 Tx Rx 4 5 6 7 8 9 GND 10 5V 12V Note See 4 3 3 COM1 Mode Selection Switch JSETCOM1 and COM1 4 Power Se...

Страница 26: ...Pin Signal 1 RS232_RX5_CCTalk 2 COM5_RTS 3 RS232_TX5_CCTalk 4 COM5_CTS 5 GND 6 GND 7 RS232_RX6_CCTalk 8 COM6_RTS 9 RS232_TX6_CCTalk 10 COM6_CTS Note See 4 3 5 COM5 6 Mode SelectionSwitch SCN1 3 on 26 COM Cable optional COM Port Cable length 250mm P N 30 20876 0000 ...

Страница 27: ... 7 GND PWR 8 GND PWR 9 Mute Mute 10 LINE2 L 11 5V PWR 1 12 5V PWR 1 13 SATA_LED 25 25mA O 14 SUS_LED O 2 15 GND PWR 16 PWRBTN_IN I 17 RSTIN I 18 GND PWR 19 SB3V3 PWR 20 LINE2 R 21 AGND PWR 22 AGND PWR 23 MIC2 L AI 24 MIC2 R AI Note 1 Maximum load is 1A Note 2 Connect SUS_LED System Power LED to the power status indicator on the chassis front panel The LED is on when the system is operating The LED...

Страница 28: ... D Type Note Pin Signal Type IOH IOL Pull U D Note 1 CASE_OPEN PU 2M I 2 SMBC OT 4mA PU 2 2K SB3V3 1 3 GND PWR 4 SMBD OT 4mA PU 2 2K SB3V3 1 5 TEMPS I 2 6 I2CC OT PU 2 2K 3V3 1 7 EXT_BAT PWR 8 I2CD OT PU 2 2K 3V3 1 9 SB3V3 PWR 10 5V PWR 11 GND PWR 12 GND PWR 13 GPIO0 PU 10K SB3V3 IOT 14 GPIO1 IOT PU 10K SB3V3 15 GPIO2 PU 10K SB3V3 IOT 16 GPIO3 IOT PU 10K SB3V3 17 GPIO4 PU 10K SB3V3 IOT 18 GPIO5 IO...

Страница 29: ...input signal must be NC MOSI Master Output Slave Input ISOLATE The ISOLATE input active low is normally NC but must be connected to GND when loading SPI flash Power Supply to the Motherboard must be turned off when loading SPI flash The pull up resistor is connected via diode to 5VSB MISO Master Input Slave Output SPI_IO2_ WP SPI Data I O A bidirectional signal used to support the new Dual IO Fast...

Страница 30: ... connect OCD0A via 1K0 pull up to 3 3V_BMC 33 3V3_LPC 13 BMC Program interface continued OCD0B Include a jumper to connect OCD0A via 1K0 pull up to 3 3V_BMC 32 GND 12 PWRBTN 31 CB_RESET Platform Reset 11 SYS_RESET 30 RST 10 CB_RESET 29 CLK33_LPC 9 CB_PWROK 28 LPC_FRAME 8 SUS_S3 27 LPC_AD3 7 SUS_S4 26 LPC_AD2 6 Test points SUS_S5 25 LPC_AD1 5 POSTWDT_DIS Connect to Jumper for Debug 24 LPC Bus LPC_A...

Страница 31: ...A_PSEL1 Clear CMOS JCMOS1 BIOS2 write protect SPI6 BIOS1 write protect SPI5 COM1 mode switch JSETCOM1 COM5 mode jumper SCN1 2 COM6 mode jumper SCN3 4 COM3 power sel JCOMPWR3 COM1 power sel JCOMPWR1 COM4 power sel JCOMPWR4 PS_ON select JPSON2 ATX AT mode JPSON1 COM2 power sel JCOMPWR2 Figure 6 AmITX RZ G Jumper and Switch Locations ...

Страница 32: ...shorted Normal default 2 3 shorted Clear CMOS 4 3 3 COM1 Mode Selection Switch JSETCOM1 Pin RS 232 default RS 422 RS 485 1 ON ON OFF 2 OFF ON ON 4 3 4 COM1 4 Power Selection Jumper JCOMPWR1 4 JCOMPWR1 4 COM1 Power 1 2 5V 2 3 NC default 3 4 12V 4 3 5 COM5 6 Mode Selection Switch SCN1 3 SCN1 3 Mode 1 3 shorted 2 4 shorted RS 232 default 3 5 shorted 4 6 shorted ccTalk ON 1 2 ...

Страница 33: ... 1 ON and 2 OFF Boot from on board BIOS and enable failsafe 4 3 7 BIOS Write protect Selection SPI5 SPI6 Pin Mode 1 2 shorted Enable 2 3 shorted BMC control default 4 3 8 SATA1 2 Power Selection SATA_PSEL1 2 Pin Mode 1 2 shorted 5V 2 3 shorted 3 3V Open Default 4 3 9 PS_ON Select JPSON2 Mode Jumper Setting PS_ON 1 2 Short for 5VA_ATX wire cut use NA 2 3 Short default ON 1 2 ...

Страница 34: ...6H 2 7P PH4 2 30 20872 0000 standard USB USB910 CST CBF 2000 1009 YOUNG YAK YY 1970H 2 5P PH2 0 30 20874 1000 optional SATA Power ST_PW1 2 JVE 24W1170 05S10 01T 3 4 CS01 YOUNG YAK YY 1970H 2 5P PH2 0 30 20875 0000 standard SATA SATA1 3 WIN WIN WATM 07ABN4B3B8UW4 30 10057 0600 standard DB 40 DB1 Molex 502790 4091 30 30016 0000 optional Feature FC1 JVE 23N6851 28S10B 01G 2 5 GR01 JWT JWT A2005H00 2C...

Страница 35: ...RZ G Driver Installation 29 5 Driver Installation Drivers can be downloaded through the following link https www adlinktech com Products Industrial_Motherboards_SBCs Mini ITXEmbeddedBoards AmITX RZ G lang en ...

Страница 36: ...30 Driver Installation This page intentionally left blank ...

Страница 37: ...tart Cause Power loss BIOS Fail Watchdog Internal Reset External Reset Fail safe BIOS support In case of a boot failure hardware signals tell external logic to boot from fail safe BIOS Flash area 1kB Flash area for customer data 128 Bytes Protected Flash area Keys IDs etc can be stored in a write and clear protectable region Board Identify Vendor Board Serial number Production Date Main current vo...

Страница 38: ...currents drawn by the board The values are sampled every 250ms The order of the 4 values is NOT in chronological order Access by the BMC may increase the drawn current of the whole system In this case there are still 3 samples not influenced by the read access Main Current MSB_n 8 LSB_n x 8 06mA 6 1 3 BMC Status This register shows the status of BMC controlled signals on the AmITX SL Table 4 SEMA ...

Страница 39: ...Exception Code command is not needed or supported Table 5 SEMA Exception Codes Exception Code Error Message 0 NOERROR 2 NO_SUSCLK 3 NO_SLP_S5 4 NO_RSMRST 5 NO_SLP_S3 6 BIOS_FAIL 7 PLTRST_FAIL 8 NO_SYS_PWRGD 9 NO_VCORE_PWRGD 10 CRITICAL_TEMP 11 NO_V12 12 NO_VRTC 13 NO_V5SBY 6 1 5 BMC Flags The BMC Flags register returns the last detected Exception Code since power up and shows the BIOS in use and t...

Страница 40: ...34 Smart Embedded Management Agent SEMA This page intentionally left blank ...

Страница 41: ...1 MB DOS Compatibility Memory 7 2 I O Map Table 8 I O Map Hex Range Device 020h 02Dh 030h 03Dh Interrupt controller 1 8259 equivalent 02Eh 02Fh SIO F81866 040h 042h 050h 052h System Timer 060h 062h 064h 066h 8042 equivalent keyboard 061h NMI control and status 070h 077h Real Time Clock Controller 092h Reset Generator 0A0h 0B1h 0B4h 0BDh Interrupt Controller 2 8259 equivalent 0B2h 0B3h APM control ...

Страница 42: ...ort 2 COM2 IRQ3 via SERIRQ PIRQ Note 1 4 Serial Port 1 COM1 IRQ4 via SERIRQ PIRQ Note 1 5 Generic N A No 6 Serial Port 3 4 5 6 COM3 4 5 6 IRQ6 via SERIRQ PIRQ Note 1 7 Generic N A No 8 Real Time clock N A No 9 Cascade Interrupt N A No 10 Generic N A No 11 Generic N A No 12 PS 2 Mouse IRQ12 via SERIRQ PIRQ No 13 Math Processor N A No 14 Generic N A No 15 Generic N A No Note 1 These IRQs can be used...

Страница 43: ... SERIRQ PIRQ No 4 Serial Port 1 COM1 IRQ4 via SERIRQ PIRQ No 5 Generic N A No 6 Serial Port 3 4 5 6 COM3 4 5 6 IRQ6 via SERIRQ PIRQ No 7 Generic N A No 8 Real Time clock N A No 9 Cascade Interrupt N A No 10 Generic N A No 11 Generic N A No 12 PS 2 Mouse IRQ12 via SERIRQ PIRQ No 13 Math Processor N A No 14 Generic N A No 15 Generic N A No 16 ACPI Compliant System N A Yes Note 1 These IRQs can be us...

Страница 44: ... N A Data Fabric 00h 18h 01h N A Data Fabric 00h 18h 02h N A Data Fabric 00h 18h 03h N A Data Fabric 00h 18h 04h N A Data Fabric 00h 18h 05h N A Data Fabric 00h 18h 06h N A Data Fabric 00h 18h 07h N A Data Fabric 01h 00h 00h Internal Intel LAN 04h 00h 00h Internal ATI VGA controller 04h 00h 01h Internal ATI HD AUDIO 04h 00h 02h Internal AMD En Decryption Controller 04h 00h 03h Internal XHCI USB co...

Страница 45: ...TC 18 INTG 30 INTG 54 INTG 54 Int3 INTH 31 INTH 55 INTF 53 INTD 19 INTD 19 INTH 31 INTH 55 INTH 55 INT Line AMD En Decryption Controller XHCI USB controller 1 XHCI USB controller 2 Multimedia Device AMD HD Audio Device AMD Controller SATA Controller Int0 INTE 52 INTE 52 INTE 52 INTE 52 INTE 52 INTE 52 INTG 54 Int1 INTF 53 INTF 53 INTF 53 INTF 53 INTF 53 INTF 53 INTH 55 Int2 INTG 54 INTG 54 INTG 54...

Страница 46: ...40 System Resources This page intentionally left blank ...

Страница 47: ...t hand column of the respective table Main Advanced Security Boot Save Exit BIOS Information System Information Board Information System Date System Time Access Level CPU Configuration Power Management System Management Thermal Management Watchdog Timer CSM Configuration SATA Configuration Super IO Configuration Serial Console Redirection Network Stack Configuration USB Configuration TPM 2 0 Confi...

Страница 48: ...cription Project Name Info only Project name CPU Board Version Info only CPU board version CPU Brand String Info only CPU brand string CPU Frequency Info only Standard CPU frequency Total Memory Info only Total memory size Memory Frequency Info only Memory frequency 8 2 3 Main Board Information Feature Options Description Board Information Info only Serial Number Info Only Display SEMA serial numb...

Страница 49: ...s increased after a HW or SW Reset or after a successful power up Boot Reason Info Only The boot reason is the event which causes the reboot of the system 8 2 4 Main System Date and Time Feature Options Description System Date Weekday MM DD YYYY Requires the alpha numeric entry of the day of the week day of the month calendar month and all 4 digits of the year indicating the century and year Fri X...

Страница 50: ...de version L1 Instruction Cache Info only Display L1 Instruction cache size L1 Data Cache Info only Display L1 data cache size L2 Cache Info only Display L2 cache size Total L3 Cache per Socket Info only Display L3 cache size PSS Support Disabled Enabled Enable disable the generation of ACPI _PPC _PSS and _PCT objects PPC Adjustment PState 0 PState 1 PState 2 Provide to adjust _PPC object NX Mode ...

Страница 51: ...CI device wake up from S5 ECO Mode Disabled Enabled Reduces the power consumption of the system but after a shut down you have to wait at least 5 seconds before you can restart the system Power Consumption Submenu Power Consumption 8 3 2 1 Advanced Power Management Power Consumption Feature Options Description Power Consumption Info only Current Input Current Info only Display actual input current...

Страница 52: ... Info only Display SEMA boot loader build date SEMA Features Submenu Flags Submenu 8 3 3 1 Advanced System Management SEMA Features Feature Options Description SEMA Features Info only Display SEMA features 8 3 3 2 Advanced System Management Flags Feature Options Description Flags Info only BMC Flags Info only Display BMC flags BIOS Select Info only Display the selection of current BIOS ROM ATX AT ...

Страница 53: ...Display board max temperature CPU Fan Speed Info only Display CPU fan speed System Fan1 Speed Info only Display system fan 1 speed System Fan2 Speed Info only Display system fan 2 speed Smart Fan Submenu Smart Fan Passive Cooling Trip Point Disabled 70 C 80 C 90 C This value is the temperature threshold of the Passive Cooling Trip Point Active Cooling Trip Point 40 C 50 C 60 C 70 C Refer to BMC Th...

Страница 54: ...Temperature Source System Fan1 Mode AUTO Smart Fan Fan On System Fan1 Mode Trigger Point 1 Info only Trigger Temperature 40 Trigger Temperature PWM Level 30 PWM Level Trigger Point 2 Info only Trigger Temperature 50 Trigger Temperature PWM Level 50 PWM Level Trigger Point 3 Info only Trigger Temperature 80 Trigger Temperature PWM Level 70 PWM Level Trigger Point 4 Info only Trigger Temperature 90 ...

Страница 55: ...NTION Pressing F12 during start up disables the Power Up Watchdog Disabled Enabled The Power Up Watchdog resets the system after a certain amount of time after power up RunTime Watchdog Disabled Enabled The RunTime Watchdog resets the system after a certain amount of time after power up 8 3 6 Advanced CSM Configuration Feature Options Description Compatibility Support Module Configuration Info onl...

Страница 56: ...uration Submenu Set Parameters of Serial Port 5 COM5 Serial Port 6 Configuration Submenu Set Parameters of Serial Port 6 COM6 8 3 8 1 Advanced Super IO Configuration Serial Port 1 Configuration Feature Options Description Serial Port 1 Configuration Info only Serial Port Disabled Enabled Enable or Disable Serial Port Device Settings Info only Serial Port Mode Info only 8 3 8 2 Advanced Super IO Co...

Страница 57: ...or compatible settings 8 3 9 1 Advanced Serial Console Redirection Console Redirection Settings COM1 Feature Options Description COM1 Console Redirection Settings Info only Terminal Type VT100 VT100 VT UTF8 ANSI Emulation ANSI Extended ASCII char set VT100 ASCII char set VT100 Extends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes Bits...

Страница 58: ...on Putty 8 3 9 2 Advanced Serial Console Redirection Legacy Console Redirection Settings Feature Options Description Legacy Console Redirection Settings Info only Resolution 80x24 80x25 On Legacy OS the Number of Rows and Columns supported redirection Redirect After POST Always Enable BootLoader When Bootloader is selected then Legacy Console Redirection is disabled before booting to legacy OS Whe...

Страница 59: ...uration Info only Network Stack Disabled Enabled Enable Disable UEFI Network Stack 8 3 11 Advanced USB Configuration Feature Options Description USB Configuration Info only USB Module version Info only USB Controllers Info only USB Devices Info only Legacy USB Support Enabled Disabled Auto Enables Legacy USB support AUTO option disables legacy support if no USB devices are connected DISABLE option...

Страница 60: ...ort 2 Enabled Disabled USB2 Port 2 USB2 Port 3 Enabled Disabled USB2 Port 3 USB2 Port 4 Enabled Disabled USB2 Port 4 USB2 Port 5 Enabled Disabled USB2 Port 5 USB2 Port 6 Enabled Disabled USB2 Port 6 USB2 Port 7 Enabled Disabled USB2 Port 7 USB3 Port 1 Port 2 Enabled Disabled USB3 Port 1 Port 2 USB3 Port 3 Port 4 Enabled Disabled USB3 Port 3 Port 4 8 3 12 Advanced TPM 2 0 Configuration Feature Opti...

Страница 61: ... devices Auto will support both with the default set to TPM 2 0 devices if not found TPM 1 2 devices will be enumerated 8 3 13 Advanced NVMe Configuration Feature Options Description NVMe controller and Drive information Info only 8 3 14 Advanced Miscellaneous Feature Options Description Miscellaneous Info only RTC Wake system from S5 Disabled Fixed Time Dynamic Time Enable or disable System wake ...

Страница 62: ...IO based C state generation and DF C states Core Thread Enablement Submenu Core Thread Enablement 8 3 15 2 Advanced AMD CBS Zen Common Options Core Thread Enablement Feature Options Description Core Thread Enablement Info only Disagree Submenu Disagree Agree Submenu Agree 8 3 15 3 Advanced AMD CBS Zen Common Options Core Thread Enablement Agree Feature Options Description Agree Info only Downcore ...

Страница 63: ...Info only Integrated Graphics Controller Disabled Forces Auto Enable Integrated Graphics controller 8 3 15 6 Advanced AMD CBS NBIO Common Options NB Configuration Feature Options Description NB Configuration Info only IOMMU Disabled Enabled Auto Enable Disable IOMMU 8 3 15 7 Advanced AMD CBS NBIO Common Options PCIe Configuration Feature Options Description PCIe Configuration Info only Pcie Dxio T...

Страница 64: ...n Secure Boot is enabled Platform Key PK is enrolled System mode is User Deployed and CSM is disabled 8 5 Boot Feature Options Description Boot Configuration Info only Setup Prompt Timeout 1 Number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Bootup NumLock State On Off Select the keyboard NumLock state Quiet Boot Disabled Enabled Enable or disables Quiet Boot ...

Страница 65: ...USB Key USB Floppy USB Lan Network Disabled Sets the system boot order Boot Option 4 Hard Disk CD DVD SD USB Hard Disk USB CD DVD USB Key USB Floppy USB Lan Network Disabled Sets the system boot order Boot Option 5 Hard Disk CD DVD SD USB Hard Disk USB CD DVD USB Key USB Floppy USB Lan Network Disabled Sets the system boot order Boot Option 6 Hard Disk CD DVD SD USB Hard Disk USB CD DVD USB Key US...

Страница 66: ...oppy USB Lan Network Disabled Sets the system boot order Boot Option 8 Hard Disk CD DVD SD USB Hard Disk USB CD DVD USB Key USB Floppy USB Lan Network Disabled Sets the system boot order Boot Option 9 Hard Disk CD DVD SD USB Hard Disk USB CD DVD USB Key USB Floppy USB Lan Network Disabled Sets the system boot order ...

Страница 67: ...ve Options Info only Save Changes Yes No Save Changes done so far to any of the setup options Discard Changes Yes No Discard Changes done so far to any of the setup options Restore Defaults Yes No Restore Load Default values for all the setup options Save as User Defaults Yes No Save the changes done so far as User Defaults Restore User Defaults Yes No Restore the User Defaults to all the setup op...

Страница 68: ...trical shock and or damage to equipment à Keep equipment away from water or liquid sources à Keep equipment away from high heat or high humidity à Keep equipment properly ventilated do not block or cover ventilation openings à Make sure to use recommended voltage and power source settings à Always install and operate equipment near an easily accessible electrical socket outlet à Secure the power c...

Страница 69: ... 408 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd Address 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology GmbH Address Hans Thoma Strasse 11 D 68163 Mannheim Germany Tel 49 621 43214 0 Fax 49 621 43214 30 Emai...

Отзывы: