AmITX-AL-I
Smart Embedded Management Agent (SEMA)
37
Exception Code
Error Message
Description
8
NO_CB_PWRGD
No signal for CB Power Good
9
CRITICAL_TEMP
Critical temperature violation
10
POWER_FAIL
Power failure
11
VOLTAGE_FAIL
Voltage failure
12
NO_3V3_5V_A_PG
No signal for 3V3_5V_A Power Good
13
NO_VNN_PG
No signal for VNN Power Good
14
NO_1V24_A_PG
No signal for 1V24_A Power Good
15
NO_VDDQ_PG
No signal for VDDQ Power Good
16
NO_V1P05S_PG
No signal for V1P05S Power Good
17
NO_SYS_GD
No signal for System Good
18
NO_V12
No V12 input
19
MEMORY_ERROR
SDRAM error
20
NO_P3V3_A_READY
No signal for P3V3_A_READY
5.1.5.
BMC Flags
The BMC Flags register returns the last detected Exception Code since power-up and shows the BIOS in use and
the power mode.
Table 6: SEMA BMC Flags
Bit
Description
[ 0 ~ 4 ]
Exception Code
[ 6 ]
0 = AT mode
1 = ATX mode
[ 7 ]
0 = Standard BIOS
1 = Fail-safe BIOS