Page 9
3.3
Pressing Pad Assembly
The pressing pads
supplied with this machine are silicone rubber. The
pressing pads must be maintained in good condition at all times and
replaced when showing signs of wear. A worn pressing pad will always
affect the quality of printing/fusing. Do not insert items into the
machine, which would tend to cut the pressing pad, i.e. buttons, pins,
press-studs or zips.
IMPORTANT NOTE:
The pressing pad
supplied with the machine is of the correct thickness.
Using a thicker pad may invalidate your warranty.
3.4
Shutting Down
To shut down the machine
when a cycle is finished, turn off the green
illuminated rocker switch on the front of the machine head.
To temporarily interrupt the cycle
, press the mode release button
once.
To shut down in an emergency
, press the red button on the front of the
machine head. If the emergency stop button is actuated, it will need to
be unlocked by turning it anticlockwise before the machine will run
again.
3.5
Fault Diagnosis
This Omega Series 1000 Press
has built in fault diagnosis. The display
may show the following:
1.
Heat Fault
If the element
of the heat press, or the thermal cut-out go open
circuit, after approximately 20 minutes the display will show
“Heat Fault”. If this display is seen, contact your machine
supplier immediately.
2.
Probe Fault
If the probe
goes open circuit, the display will show “Probe
Fault” immediately. Contact your machine supplier
immediately.
3.
“CAL” Fault
If “CAL” appears
in the controller display the controller will
need to be recalibrated. Switch off the machine and contact
your supplier for an instruction sheet.