Page 9
Working with Heat Transfer Materials (cont.)
3.2.5
Start the sequence
by pulling the handle release knob to
unlock the handle from its vertical position. Pull the handle
down to the lock position using both hands on the handle. This
will make the micro switch, which starts the timer. When the
set time has elapsed, the buzzer sounds. The handle is then
unlocked and returned to the vertical position again using both
hands. The head may then be swung aside for unloading and
loading
3.2.6
For safety reasons,
it is necessary to push the handle into the
locked position after it is lifted. This will ensure against the
accidental lowering of the heat platen handle.
3.3
Pressing Pad Assembly
The pressing pad
normally supplied with this machine is silicone
rubber. Alternatively, a pad of foam with a “Nomex” cover may be
supplied to special order. The pressing pad must be maintained in good
condition at all times and replaced when showing signs of wear. A
worn pressing pad will always affect the quality of printing/fusing. Do
not insert items into the machine, which would tend to cut the pressing
pad, i.e. buttons, pins, press studs or zips.
Never leave
the hot heat plate in contact with the pressing pad when the
machine is not in use.
IMPORTANT NOTE:
The pressing pad
supplied with the machine is of the correct thickness.
Using a thicker pad may invalidate your warranty.
3.4 Shutting
Down
To shut down the machine
, turn off the green illuminated rocker
switch on the operator’s left side of the machine head and then remove
the mains plug from the power supply.
N.B.
The handle should be in the up position.
3.5 Fault
Diagnosis
The machines
have built in fault diagnosis. The display may show the
following:
1.
P-F
If the probe
goes open circuit, the display will show “P-F” and
a buzzer will sound. Contact your machine supplier
immediately.