5.5 Controller Electrical Diagram
DI1
J4 AC L
Heat Sink
XS1
XS2
XS1
XS2
To
Controller
Facia
J3
1. Jumper 'ON'
for Manual Press
2. Jumper 'OFF'
for Auto Press
RT-
RT+
GND
DI2
GND
J7 AC N
J6
J5
N
To
Element
Air Solenoid
1. Connect to 'Push Button 2'
if installing in an 'Automatic Press'
2. No connection in a 'Manual Press'
1. Connect to 'Push Button 1'
if installing in an 'Automatic Press'
2. Connect to 'Microswitch' if
installing in a 'Manual Press'
To Mains
Earth Stud
'Ribbon Cable'
Sockets
Buzzer
+
Green
(Probe)
-
White
L
N
from Mains
(via Switch)
L
J8
J9
J10
AIR
PGND
MAIN
BOARD
POWER BOARD
J2
1. Jumper 'ON'
for Centigrade
2. Jumper 'OFF'
for Farenheight
J1
Page 18