background image

 

               

Keypad & Proximity Flash Mount Reader Installation Manual

 

 
Model:ADK-DTA16/AC 

 

Mounting: 

1. 

Install the metal plate on the wall with two or four screws, which depends on different kinds of gang box 

being installed.   

2. 

The cover shall clip on the upper edge first and then push in the bottom part. 

3. 

Tighten the secure non-dropout screw, which located underneath of the reader to fix the reader and the 

back plate. 

4. Installation 

completed. 

Recommendation: 

1. 

Linear DC Power Supply; 

2.      22AWG shielded cable; it’s required to do “one-point” ground. (As shown in the diagram) 

 

 

 

 

 

 

 

 

Dimension (mm) 

 

 

 

 

 

 

Power up Sequences: 

1. 

When reader is powered up, the Red LED will flash once, then the Green LED will flicker for 5times. The 

reader will beep twice and the reader is in Ready mode. Red LED will continue to be ON. 

2. 

Present the card. The Green LED will flash once; buzzer will beep once.   

3. 

When keypad is being pressed, Green LED will flash once, buzzer will beep once. 

Wiring: 

Color 

Description 

Red 

Power Supply to the reader 

Black 

Signal GND 

Green 

Wiegand Output data, D0 

White 

Wiegand Output data, D1 

Blue 

Green LED control, active low 

Brown 

Buzzer input, active low 

Troubleshooting:

 

Trouble List 

Solution 

No Response 

when Power Up 

 

Discount the power and confirm that the power supply cable is correctly 

connected (See “Wiring” above). 

 

Check the input voltage is sufficient (See “Specifications” above). 

Auto Restart 

 

Check the input voltage is sufficient (See “Specifications” above). 

Cannot read card 

number correctly

 

Check the format setting on the controller if it is the same as the card format. 

Use approved card (known format and Facility Code) to test. 

 

Check if the shield cable is correctly connected to Classis Ground at ONE 

point only. 

Reader beeps but 

No card data info

 

Check if data 0 & data 1 cable is correctly connected (See “Wiring” above). 

 

Check the input voltage at the card reader end is correct (See “Specifications” 

above). 

Buzzer error 

 

Check if the buzzer cable is correctly connected (See “Wiring” above). 

LED Status Error

 

Check the Led cable is correctly connected (See “Wiring” above). 

 

Use Default Configuration Card to set it back to normal. 

 

Input Voltage (at Reader end) 

DC10V~15V 

Typical Read range 

> 5cm 

Operating Current 

100mA (max) 

Maximum Cable Length 

150m 

Operating Temperature 

-30ºC~70 ºC 

Number pad format 

8 bits burst by default 

Humidity Range(%) 

10-90

 

 

 