ADJ WiFly EXR Dotz Par Скачать руководство пользователя страница 5

ADJ Products, LLC  -  www.adj.com  - WiFly EXR Dotz Par User Manual Page 9

ADJ Products, LLC  -  www.adj.com  - WiFly EXR Dotz Par User Manual Page 8

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer runs  of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 

may be implemented in a 3-pin XLR DMX line. When inserting standard 

5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  WiFly EXR Dotz Par                                                  Set Up

Power Supply:

 The ADJ WiFly EXR Dotz Par contains a automatic 

voltage switch, which will auto sense the voltage when it is plugged 

into a power source. With this switch there is no need to worry about 

the correct power voltage, this unit can be plugged in anywhere.   

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The WiFly EXR Dotz Par can be controlled via DMX-512 protocol. The 

WiFly EXR Dotz Par has 4 DMX Channel Modes. The DMX address is 

set on the rear panel of the WiFly EXR Dotz Par. Your  unit  and  your 

DMX controller require a approved DMX-512 110 Ohm Data cable for 

data  input  and  data  output  (Figure  1).  We  recommend  Accu-Cable 

DMX cables. If you are making your own cables, 

be sure to use standard 110-120 Ohm shielded 

cable  (This  cable  may  be  purchased  at  almost 

all professional sound and lighting stores). Your 

cables should be made with a male and female 

XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained 

and cannot be split.

  WiFly EXR Dotz Par                                                  Set Up

Figure 1

Содержание WiFly EXR Dotz Par

Страница 1: ...t names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and...

Страница 2: ...perfect operating condition Carefully check the shipping carton for damage that may have occurred during ship ping If the carton appears to be damaged carefully inspect your fix ture for any damage an...

Страница 3: ...inclu ding amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has bee...

Страница 4: ...the electrolyte gel or other DO NOT use the battery A battery with a odor of electrolyte or a gel leakage should be placed away from fire to avoid fire or explosion 4 Battery Storage When storing the...

Страница 5: ...5 Pin XLR Male In 3 Pin XLR Female Out Pin 1 Do Not Use Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Ground Shield 3 Pin XLR to 5 Pin XLR Convers...

Страница 6: ...s the strobe off 01 is the slowest strobe rate and 99 is the fast est strobe rate Press ENTER once you find your desired strobe setting WiFly EXR Dotz Par System Menu Control Panel Lock The control pa...

Страница 7: ...er the setting Use the UP or DOWN buttons to activate On or deactivate Off the remote control WiFly EXR Dotz Par System Menu RGB Dimmer Mode Select your desired color to remain static or adjust the RG...

Страница 8: ...Follow the instructions on page 14 to set the Wireless channel The address must match the address set on the WiFly Transceiver 2 After you have set the WiFly address follow the DMX instructions on pag...

Страница 9: ...arge To recharge the battery switch off the battery on off switch Plug the provided I E C power cord into a power outlet When the charge indicator LED is red the unit is charging When the charge indic...

Страница 10: ...0 255 0 100 WiFly EXR Dotz Par 5 s Channel Mode Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 WiFly EXR Dotz Par 3 Channel Mode Channel Value Function 1 RED 0 255 0...

Страница 11: ...52 159 20 R 0 G 129 B 184 160 167 21 R 0 G 83 B 115 168 175 22 R 0 G 97 B 166 176 183 23 R 1 G 100 B 167 184 191 24 R 0 G 40 B 86 192 199 25 R 209 G 219 B 182 200 207 26 R 42 G 165 B 85 208 215 27 R 0...

Страница 12: ...3 82 5 10 6 37 66 Diameter m 5 21 2 61 7 82 10 43 13 03 103 Diameter m 2470 3260 5060 11950 815 1054 1644 3280 406 540 839 1545 241 316 486 940 147 198 324 611 Intensity LUX Beam angle Field angle 25...

Страница 13: ...expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or re...

Страница 14: ...rking Position Any safe working position Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written...

Отзывы: