ADJ Vizi Q Wash7 Скачать руководство пользователя страница 3

For Your Own Personal Safety, Please Read and Understand This 

Manual Completely Before You Attempt To Install Or Operate 

This Unit!

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Be sure that the local power outlet match that of the required volt-

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been 

   frayed or broken. 

•   Do not attempt to remove or break off the ground prong from    

   the electrical cord. This prong is used to reduce the risk of electrical  

   shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out-

   doors voids all warranties.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to cords at plugs, convenience recep- 

   tacles, and the point where they exit from the appliance. 

• Cleaning -The fixture should be cleaned only as recommended by  

   the manufacturer. See page 45 for cleaning details.

•   Heat -This fixture should be situated away from heat sources such 

   as radiators, heat registers, stoves, or other appliances (including 

   amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. Objects have fallen, or liquid has been spilled into the appliance.

    B. The appliance has been exposed to rain or water.

    C. The appliance does not appear to operate normally or exhibits a  

     

  

 marked change in performance.

  Vizi Q Wash7  

 

                       Safety Precautions

ADJ Products, LLC  -  www.adj.com  - Vizi Q Wash7 Instruction Manual Page 4

•   DMX-512 Protocol Compatible (3 DMX Modes: 17 DMX Channel  

   Mode, 19 DMX Channel Mode, and 23 DMX Channel Mode)

•  Pan & Tilt Invert

•  PowerCON Inputs & Outputs

•  3-Pin & 5-Pin XLR Inputs & Outputs

•  Color Individual RGBW Control

•  2 Operating Modes - Auto Program & DMX Control

•  Built-In ADJ’s WiFly EXR Wireless DMX Up to 2,500 feet/760M

•  Stand Alone Setup or Master-Slave Configuration

•   Edit and Save Scenes into the Memory

  Vizi Q Wash7  

 

                                       Features

ADJ Products, LLC  -  www.adj.com  - Vizi Q Wash7 Instruction Manual Page 5

Caution!

 There are no user serviceable parts inside this unit. Do not 

attempt  any  repairs  yourself,  doing  so  will  void  your  manufactures 

warranty.  In  the  unlikely  event  your  unit  may  require  service  please 

contact ADJ Products, LLC.

During operation the housing may become extremely hot. Avoid touch-

ing the unit with bare hands while in use.
ADJ Products, LLC will not accept any liability for any resulting dam-

ages caused by the non-observance of this manual or any unauthor-

ized modification to this unit.

  Vizi Q Wash7  

                            Handling Precautions

The Vizi Q Wash7 carries a two year limited warranty. Please fill out 

the  enclosed warranty  card to validate your purchase. All returned 

service  items  whether  under  warranty  or  not,  must  be  freight  pre-

paid and accompany a return authorization (R.A.) number. The R.A. 

number must be clearly written on the outside of the return package. 

A brief description of the problem as well as the R.A. number must 

also be written down on a piece of paper and included in the shipping 

carton. If the unit is under warranty, you must provide a copy of your 

proof of purchase invoice. You may obtain a R.A. number by con-

tacting our customer support team on our toll free customer support 

number. All packages returned to the service department not display-

ing a R.A. number on the outside of the package will be returned to 

the shipper at the shippers cost.

  Vizi Q Wash7  

 

                    Product Registration

Содержание Vizi Q Wash7

Страница 1: ...nds and product names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipmen...

Страница 2: ...to enhance the beams projec tions Customer Support ADJ Products LLC provides a toll free cus tomer support line to provide help and to answer any question should you encounter problems during your se...

Страница 3: ...nce does not appear to operate normally or exhibits a marked change in performance Vizi Q Wash7 Safety Precautions ADJ Products LLC www adj com Vizi Q Wash7 Instruction Manual Page 4 DMX 512 Protocol...

Страница 4: ...ting removing or servicing the unit Overhead mounting requires extensive experience including calculat ing working load limits installation material being used and perodic safety inspection of all ins...

Страница 5: ...s serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language a...

Страница 6: ...round Special Note Line Termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which...

Страница 7: ...r 3 Use the controller s faders to control the various DMX fixture traits 4 This will allow you to create your own programs 5 Follow the directions on page 24 to select your DMX Channel mode and to se...

Страница 8: ...RAM 13 251 255 PROGRAM 14 13 PROGRAM SPEED 0 255 SLOW FAST 14 AUTO PROGRAM FADE 0 NORMAL 0 255 SLOW FAST 15 DIMMER MODE 0 20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DE...

Страница 9: ...OBE PULSE SLOW FAST 160 191 LED ON 192 223 RANDOM STROBE SLOW FAST 224 255 LED ON 11 MASTER DIMMER 0 255 0 100 12 DIMMER FINE 0 255 0 100 13 FOCUS 0 255 NEAR FAR Vizi Q Wash7 19 Channel DMX Mode Stand...

Страница 10: ...Mode Extend Channel Value Function 1 0 255 PAN MOVEMENT 8bit 540 or 630 2 0 255 PAN MOVEMENT FINE 16bit 3 0 255 TILT MOVEMENT 8bit 4 0 255 TILT MOVEMENT FINE 16bit 5 0 255 RED CENTER LED 0 100 6 0 255...

Страница 11: ...RAM 13 251 255 PROGRAM 14 19 PROGRAM SPEED 0 255 SLOW FAST 20 AUTO PROGRAM FADE 0 NORMAL 0 255 SLOW FAST 21 DIMMER MODE 0 20 STANDARD 21 40 STAGE 41 60 TV 61 80 ARCHITECTURAL 81 100 THEATRE 101 255 DE...

Страница 12: ...ED GREEN BLUE WHITE RED GREEN BLUE WHITE OFF 0 0 0 0 0 Color33 129 132 255 206 143 0 Color1 1 4 80 255 234 80 Color34 133 136 254 177 153 0 Color2 5 8 80 255 164 80 Color35 137 140 254 192 138 0 Color...

Страница 13: ...T or RIGHT buttons to scroll through the 3 DMX Chan nel Modes Standard Mode This is 19 Channel Mode Basic Mode This is 17 Channel Mode Extended Mode This is 23 Channel Mode User Mode A B C These are c...

Страница 14: ...buttons so that Function is highlighted then press ENTER 2 Press the LEFT or RIGHT buttons until Status is displayed press ENTER Vizi Q Wash7 System Menu Vizi Q Wash7 System Menu the address that is...

Страница 15: ...current stand by setting will be displayed use the LEFT or RIGHT buttons to adjust the hibernation period between 01M 99M or Off 5 Press ENTER to confirm your selection or press MODE to exit Vizi Q W...

Страница 16: ...LED See page 44 for the Dimmer Curve Chart 1 Press the MODE button to access the main menu Press the UP or DOWN buttons so that Function is highlighted then press ENTER Vizi Q Wash7 System Menu that F...

Страница 17: ...ctivate WiFly and set the wireless address This address must match the address that is set to WiFly TransCeiver Vizi Q Wash7 System Menu or WiFly controller 1 Plug the fixture in and access the main m...

Страница 18: ...Vizi Q Wash7 System Menu Auto Pro This function allows the internal programs to run in either stand alone or master slave mode In Master mode the fixture will send DMX data to other fixtures connect...

Страница 19: ...IGHT but tons to toggle between 5 Press ENTER to confirm or press MODE to exit Temp Info This will allow you to check the moving head tempera ture 1 Press the MODE button to access the main menu Press...

Страница 20: ...Wash7 features an integrated DMX recorder Preprogrammed scenes can be transmitted to the fixture via any DMX compliant controller This function allows those scenes to be stored in to the fixture s bu...

Страница 21: ...n menu and press the UP or DOWN buttons so that Function is highlighted then press ENTER 7 Press the UP or DOWN buttons until Disp Set is displayed and press ENTER Vizi Q Wash7 Operation Vizi Q Wash7...

Страница 22: ...6020 14000 1718 3410 484 4002 9387 Field angle 10 0 0 1 3 5 8 10 1 1 2 2 3 4 Beam opening m 3 4 7 0 23 0 11 0 31 0 41 0 51 7 Diameter m 10 0 37 0 17 0 53 0 73 0 90 10 Diameter m Vizi Q Wash7 Photomet...

Страница 23: ...ns No light output from the unit 1 Be sure the external fuse has not blown The fuse is located on the back panel of the unit next to the PowerCON input connec tion 2 Be sure the fuse holder is complet...

Страница 24: ...hout any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied with products des...

Отзывы: