nect the cable’s shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR’s outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
Ultra Hex Bar 6
Set Up
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OUT
3-PIN XLR
Figure 2
Figure 3
1 Ground
1 Ground
XLR Male Socket
XLR Pin Configuration
3 Hot
2 Cold
2 Cold
3 Hot
XLR Female Socket
Pin 3 = Data True (positive)
Pin 2 = Data Compliment (negative)
Pin 1 = Ground
Special Note: Line Termination.
When longer runs of cable are
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ Products, LLC part number Z-DMX/T) will decrease the possibili-
ties of erratic behavior.
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces signal errors and
avoids signal transmission problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OUT
3-PIN XLR
Figure 4
5-Pin XLR DMX Connectors.
Some manufactures use 5-pin DMX-
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX
fixtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used,
these adaptors are readily available at most electric stores. The chart
below details a proper cable conversion.
Conductor
5-Pin XLR Male (In)
3-Pin XLR Female (Out)
Pin 1
Do Not Use
Do Not Use
Pin 3
Pin 2
Pin 1
Pin 3
Pin 2
Not Used
Not Used
Data True (+ signal)
Data Compliment (- signal)
Ground/Shield
3-Pin XLR to 5-Pin XLR Conversion
ADJ Products, LLC - www.adj.com - Ultra Hex Bar 6 User Manual Page 6
ADJ Products, LLC - www.adj.com - Ultra Hex Bar 6 User Manual Page 17
Ultra Hex Bar 6 12 Channel - DMX Values & Functions
Channel Value
Function
1 RED
0 - 255 0% - 100%
2 GREEN
0 - 255 0% - 100%
3 BLUE
0 - 255 0% - 100%
4 WHITE
0 - 255 0% - 100%
5 AMBER
0 - 255 0% - 100%
6 UV
0 - 255 0% - 100%
7 COLOR MACROS
0 - 255 (See Color Macro Chart on page 19)
8 STROBING
0 - 31 OFF
32 - 63 LED ON
64 - 95 STROBING SLOW - FAST
96 - 127 LED ON
128 - 159 STROBE PULSE SLOW - FAST
160 - 191 LED ON
192 - 223 RANDOM STROBING
224 - 255 LED ON
9 MASTER DIMMER
0 - 255 0% - 100%
10 PROGRAMS
0 OFF
1 - 24 PROGRAM 1
25 - 35 PROGRAM 2
36 - 46 PROGRAM 3
47 - 57 PROGRAM 4
58 - 68 PROGRAM 5
69 - 79 PROGRAM 6
80 - 90 PROGRAM 7