ADJ ULTRA HEX BAR 6 Скачать руководство пользователя страница 7

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

 Ultra Hex Bar 6   

                                           Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ Products, LLC part number Z-DMX/T) will decrease the possibili-

ties of erratic behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

ADJ Products, LLC  -  www.adj.com  - Ultra Hex Bar 6 User Manual Page 6

ADJ Products, LLC  -  www.adj.com  - Ultra Hex Bar 6 User Manual Page 17

 Ultra Hex Bar 6         12 Channel - DMX Values & Functions

  Channel   Value  

                  Function

       

1                                                       RED

                        0 - 255                        0% - 100%           

       2                                                     GREEN

        

                                                                               

                 

                        0 - 255                        0% - 100%

       3                                                      BLUE

                        0 - 255                        0% - 100%

       4                                                     WHITE

                        0 - 255                        0% - 100%

       5                                                     AMBER

                        0 - 255                        0% - 100% 

       6                                                        UV

                        0 - 255                        0% - 100%

       7                                              COLOR MACROS                                

                        0 - 255     (See Color Macro Chart on page 19)

    

       

8                                                 STROBING 

                        0 - 31                               OFF

                      32 - 63                            LED ON

                      64 - 95              STROBING SLOW - FAST

                      96 - 127                          LED ON

                    128 - 159         STROBE PULSE SLOW - FAST

                    160 - 191                          LED ON

                    192 - 223                RANDOM STROBING

                    224 - 255                          LED ON

       9                                             MASTER DIMMER

                        0 - 255                        0% - 100%

      

10                                                 PROGRAMS

                           0                                    OFF

                        1 - 24                         PROGRAM 1

                      25 - 35                         PROGRAM 2

                      36 - 46                         PROGRAM 3

                      47 - 57                         PROGRAM 4

                      58 - 68                         PROGRAM 5

                      69 - 79                         PROGRAM 6                      

                      80 - 90                         PROGRAM 7

Содержание ULTRA HEX BAR 6

Страница 1: ...40 Degrees Working Position Any safe working position Power Draw 55W Power Cord Daisy Chain 12 Fixtures Max Fuse 2 Amp Weight 6lbs 2 82Kgs Dimensions 23 L x 4 5 W x 6 5 H 585 x 110 x 165mm Colors RGBA...

Страница 2: ...whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any man...

Страница 3: ...r unit may require service please contact ADJ Products LLC PLEASE recycle the shipping carton when ever possible ADJ Products LLC www adj com Ultra Hex Bar 6 User Manual Page 21 Ultra Hex Bar 6 Troubl...

Страница 4: ...a copy of your proof of purchase invoice You may obtain a R A number by contacting our customer support team on our customer support number All pack ages returned to the service department not displa...

Страница 5: ...when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does no...

Страница 6: ...ble DMX Cable Requirements For DMX Operation The Ultra Hex Bar 6 can be controlled via DMX protocol The Ultra Hex Bar 6 has 5 DMX channel modes please see pages 7 8 for the different modes Your unit a...

Страница 7: ...DMX COMMON 1 2 3 Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX...

Страница 8: ...Choose one of the six colors to remain static or adjust the intensity of each color to make your own color Sound Active mode The unit will react to sound chasing through the built in programs There ar...

Страница 9: ...in the fixture via the XLR connections to any standard DMX controller RGBWA UVDimmer Mode 1 Plug the fixture in and press the MODE button until MANUAL is displayed 2 When RED XXX is displayed you are...

Страница 10: ...buttons to scroll through the 20 programs Once you have found your desired program press the SET UP button to adjust the program speed 3 SPEED XX will be displayed Use the UP or DOWN button to adjust...

Страница 11: ...ww adj com Ultra Hex Bar 6 User Manual Page 13 The ADJ RFC remote sold seperately has many different functions and allows you to control your Ultra Hex Bar 6 from long distance The ADJ RFC remote can...

Страница 12: ...that in case the DMX signal is lost the operating mode chosen in the setup is the running mode the fixture will go into when the DMX signal is lost You can also set this as the operating mode you wou...

Отзывы: