ADJ SAB605 Скачать руководство пользователя страница 3

For Your Own Personal Safety, Please Read and Understand This 

Manual Completely Before You Attempt To Install Or Operate 

This Unit!

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Be sure that the local power outlet match that of the required volt-

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been 

   frayed or broken. 

•   Do not attempt to remove or break off the ground prong from    

   the electrical cord. This prong is used to reduce the risk of electrical  

   shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out-

   doors voids all warranties.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to cords at plugs, convenience recep- 

   tacles, and the point where they exit from the appliance. 

• Cleaning -The fixture should be cleaned only as recommended by  

   the manufacturer. See page 33 for cleaning details.

•   Heat -This fixture should be situated away from heat sources such 

   as radiators, heat registers, stoves, or other appliances (including 

   amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. Objects have fallen, or liquid has been spilled into the appliance.

    B. The appliance has been exposed to rain or water.

    C. The appliance does not appear to operate normally or exhibits 

         a marked change in performance.

 Saber Spot RGBW  

 

             Safety Precautions

ADJ Products, LLC  -  www.adj.com  - Saber Spot RGBW Instruction Manual Page 5

ADJ Products, LLC  -  www.adj.com  - Saber Spot RGBW Instruction Manual Page 4

Power Supply:

 The ADJ Saber Spot RGBW contains a automatic 

voltage switch, which will auto sense the voltage when it is plugged 

into the power source. With this switch there is no need to worry about 

the correct power voltage, this unit can be plugged in anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A  DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of different manufactures to be linked together and operate from a 

single  controller,  as  long  as  all  fixtures and  the  controller  are DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Saber Spot RGBW can be controlled via DMX-512 

protocol. The Saber Spot RGBW has 12 DMX channel modes. The 

DMX address is set electronically using the con-

trols on the rear panel of the unit. Your unit and 

your DMX controller require a approved DMX-512 

110 Ohm Data cable for data input and data output 

(Figure 1). We recommend Accu-Cable DMX cables. 

If you are making your own cables, be sure to use 

standard 110-120 Ohm shielded cable (This cable 

may be purchased at almost all professional sound 

and lighting stores). Your cables should be made 

 Saber Spot RGBW                                             DMX Set Up

Figure 1

Содержание SAB605

Страница 1: ...are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electri...

Страница 2: ...nit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Saber Spot RGBW General Instructio...

Страница 3: ...ADJ Products LLC www adj com Saber Spot RGBW Instruction Manual Page 4 Power Supply The ADJ Saber Spot RGBW contains a automatic voltage switch which will auto sense the voltage when it is plugged in...

Страница 4: ...X512 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT DMX512 DMX DMX COMMON 1 2 3 Termination redu...

Страница 5: ...nd your desired DMX channel mode and press ENTER to confim and exit SLAVE This will let you set the unit as the slave in a master slave configuration 1 Press the MENU button until SLAVE is displayed p...

Страница 6: ...l automatically go into stand by mode Hold If the DMX signal is lost the fixture will stay in the last DMX setting If power is applied and this mode is set the unit will automatically go into the last...

Страница 7: ...l Temp Val is displayed press ENTER 2 The fixture temperature will now be displayed Press MENU to exit Saber Spot RGBW System Menu AUTOLOCK With this function you can have the keys lock off after 10 s...

Страница 8: ...linked together to run a built in program 1 Press the MENU button until Look is displayed and press ENTER 2 Press the UP or DOWN buttons to find your desired show Saber Spot RGBW Operation Saber Spot...

Страница 9: ...ns mitters the app is a free download from the app store for your iOS phone or tablet The app comes with 3 pages of control depending on the IR fixture you are using Please see below for IR functions...

Страница 10: ...Channel Mode Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 WHITE 0 255 0 100 5 MASTER DIMMER 0 255 0 100 Saber Spot RGBW 5 Channel Mode Channel Value Function 1 HUE...

Страница 11: ...5 SHUTTER STROBE 0 31 LED OFF 32 63 LED ON 64 95 STROBING SLOW FAST 96 127 LED ON 128 159 PULSE STROBE SLOW FAST 160 191 LED ON 192 223 RANDOM STROBE SLOW FAST 224 255 LED ON 6 MASTER DIMMER 0 255 0 1...

Страница 12: ...FINE 0 255 0 100 Saber Spot RGBW 8 Channel Mode Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 WHITE 0 255 0 100 5 SHUTTER STROBE 0 31 LED OFF 32 63 LED ON 64 95 STR...

Страница 13: ...0 255 0 100 5 COLOR MACROS 0 255 SEE PAGES 30 31 FOR CHART 6 AUTO PROGRAMS 0 OFF 1 20 PROGRAM 1 21 40 PROGRAM 2 41 60 PROGRAM 3 61 80 PROGRAM 4 81 100 PROGRAM 5 101 120 PROGRAM 6 121 140 PROGRAM 7 141...

Страница 14: ...ot RGBW Instruction Manual Page 27 Channel Value Function 1 SHUTTER STROBE 0 31 LED OFF 32 63 LED ON 64 95 STROBING SLOW FAST 96 127 LED ON 128 159 PULSE STROBE SLOW FAST 160 191 LED ON 192 223 RANDOM...

Страница 15: ...55 DEFAULT DIMMER SETTING Saber Spot RGBW 12 Channel Mode Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 WHITE 0 255 0 100 5 COLOR MACROS 0 255 SEE PAGES 30 31 FOR C...

Страница 16: ...120 99 0 255 100 Color63 249 252 0 0 189 0 Color31 121 124 138 169 255 138 Color64 253 255 255 255 255 0 Color32 125 128 255 255 255 255 Saber Spot RGBW Color Macro Chart Saber Spot RGBW Color Macro...

Страница 17: ...be carried out periodically to optimize light output Cleaning frequency depends on the environ ment in which the fixture operates I e smoke fog residue dust dew In heavy club use we recommend cleanin...

Страница 18: ...e reliability of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization was issued to purchaser by ADJ Products L...

Отзывы: