For Your Own Personal Safety, Please Read and Understand This 

Manual Completely Before You Attempt To Install Or Operate 

This Unit!

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Be sure that the local power outlet match that of the required volt-

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been 

   frayed or broken. 

•   Do not attempt to remove or break off the ground prong from    

   the electrical cord. This prong is used to reduce the risk of electrical  

   shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out-

   doors voids all warranties.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to cords at plugs, convenience recep- 

   tacles, and the point where they exit from the appliance. 

• Cleaning -The fixture should be cleaned only as recommended by  

   the manufacturer. See page 23 for cleaning details.

•   Heat -This fixture should be situated away from heat sources such 

   as radiators, heat registers, stoves, or other appliances (including 

   amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. Objects have fallen, or liquid has been spilled into the appliance.

    B. The appliance has been exposed to rain or water.

    C. The appliance does not appear to operate normally or exhibits 

         a marked change in performance.

 Par Z4  

 

                                 Safety Precautions

ADJ Products, LLC  -  www.adj.com  - Par Z4 Instruction Manual Page 5

ADJ Products, LLC  -  www.adj.com  - Par Z4 Instruction Manual Page 4

Power Supply:

 The ADJ Par Z4 contains a automatic voltage switch, 

which will auto sense the voltage when it is plugged into the power 

source. With this switch there is no need to worry about the correct 

power voltage, this unit can be plugged in anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A  DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of different manufactures to be linked together and operate from a 

single  controller,  as  long  as  all  fixtures and  the  controller  are DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Par Z4 can be controlled via DMX-512 protocol. The 

Par Z4 four DMX channel modes; 4 channel mode, 6 channel mode, 

8  channel  mode,  &  9  channel  mode.  The  DMX 

address is set electronically using the controls on 

the front panel of the unit. Your unit and your DMX 

controller require a approved DMX-512 110 Ohm 

Data cable for data input and data output (Figure 

1). We recommend Accu-Cable DMX cables. If you 

are making your own cables, be sure to use stan-

dard 110-120 Ohm shielded cable (This cable may 

be purchased at almost all professional sound and 

 Par Z4 

                                                      DMX Set Up

Figure 1

Содержание PAR Z4

Страница 1: ...oduct names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building...

Страница 2: ...of this unit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Par Z4 General Instructi...

Страница 3: ...age 5 ADJ Products LLC www adj com Par Z4 Instruction Manual Page 4 Power Supply The ADJ Par Z4 contains a automatic voltage switch which will auto sense the voltage when it is plugged into the power...

Страница 4: ...DMX512 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT DMX512 DMX DMX COMMON 1 2 3 Termination r...

Страница 5: ...or DOWN buttons to find your desired address Press ENTER to set your desired DMX address CHND This will let select your desired DMX channel mode 1 Press the either the MENU button until CHND is displa...

Страница 6: ...o into stand by mode LAST If the DMX signal is lost the fixture will stay in the last DMX setting If power is applied and this mode is set the unit will automatically go into the last DMX set up Par Z...

Страница 7: ...or DISP to revert the display to normal 3 Press ENTER to confirm Par Z4 System Menu BALA With this function you can adjust the RGB colors to balance out the white color 1 Press the MENU button until B...

Страница 8: ...s 2 To control your fixture in DMX mode follow the set up procedures on pages 7 9 as well as the set up specifications that are includ ed with your DMX controller 3 Use the controller s faders to cont...

Страница 9: ...ll allow you to link up to 16 units together and operate without a controller In a Master Slave set up one unit will act as the controlling unit and the others will react to the controlling units prog...

Страница 10: ...0 231 SLOW CLOSE FAST OPEN 232 239 LED ON 240 247 RANDOM STROBE SLOW FAST 248 255 LED ON 6 MASTER DIMMER 0 255 0 100 Par Z4 6 Channel Mode Channel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100...

Страница 11: ...7 77 Color40 157 160 234 139 171 0 Color8 29 32 255 200 74 74 Color41 161 164 224 5 97 0 Color9 33 36 255 166 77 77 Color42 165 168 175 77 173 0 Color10 37 40 255 125 74 74 Color43 169 172 119 130 199...

Страница 12: ...bass should cause the unit to react to sound Tapping on the microphone quiet or high pitched sounds may not activate the unit Due to fog residue smoke and dust cleaning the internal and exter nal opti...

Страница 13: ...ADJ Products LLC www adj com Par Z4 Instruction Manual Page 24 ADJ Products LLC www adj com Par Z4 Instruction Manual Page 25 Par Z4 Notes Par Z4 Notes...

Страница 14: ...ion to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Exc...