ADJ Products, LLC - www.adj.com - MOD HEX100 User Manual Page 8
MOD HEX100
DMX Set Up
DMX-512:
DMX is short for Digital Multiplex. This is a universal protocol used as a form of commu
-
nication between intelligent fixtures and controllers.
A DMX controller sends DMX data instructions
from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only
have a DATA “OUT” terminal).
DMX Linking:
DMX is a language allowing all makes and models of di昀昀erent manufactures to be
linked together and operate from a single controller, as long as all 昀椀xtures and the controller are DMX
compliant.
To ensure proper DMX data transmission, when using several DMX fixtures try to use
the shortest cable path possible. The order in which fixtures are connected in a DMX line does not
influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed
anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that
unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation):
The MOD HEX100
can be controlled via DMX-512 protocol. The MOD HEX100 has 5 DMX channel
modes. The DMX address is set on the rear panel of the MOD HEX100. Your unit
and your DMX controller require a standard 3-pin XLR connector for data input and
data output (Figure 1). We recommend Accu-Cable DMX cables. If you are making
your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable
may be purchased at almost all pro lighting stores). Your cables should be made
with a male and female XLR connector on either end of the cable. Also remember
that DMX cable must be daisy chained and cannot be split.
Figure 1
Notice:
Be sure to follow 昀椀gures two and three when making your own cables. Do not use the ground
lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the
shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a
short circuit and erratic behavior.
DMX512 IN
3-PIN XLR
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 O T
3-PIN XLR
Figure 2
Figure 3
1 Ground
1 Ground
XLR Male Socket
XLR Pin Con昀椀guration
3 Hot
2 Cold
2 Cold
3 Hot
XLR Female Socket
Pin 3 = Data True (positive)
Pin 2 = Data Compliment (negative)
Pin 1 = Ground