ADJ H20 DMX IR Скачать руководство пользователя страница 3

©

ADJ Products, LLC  -  www.adj.com  - H2O DMX IR Instruction Manual Page 5

ADJ Products, LLC  -  www.adj.com  - H2O DMX IR Instruction Manual Page 4

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids into or on to your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 16 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel    

   when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

  H2O DMX IR  

 

                            Safety Precautions

Power Supply:

 The ADJ H2O DMX IR contains a automatic voltage 

switch, which will auto sense the voltage when it is plugged into the 

power source. With this switch there is no need to worry about the cor-

rect power voltage, this unit can be plugged in anywhere.  

DMX-512:

 

DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal).

 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-

gle controller, as long as all fixtures and the controller are DMX com-

pliant. To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The H2O DMX IR is a three channel DMX unit. The DMX address is set 

on the top panel of the H2O DMX IR. Your unit and your DMX control-

ler require a approved DMX-512 110 Ohm Data cable for data input 

and data output. We recommend Accu-Cable DMX cables. If you are 

making your own cables, be sure to use standard 110-120 Ohm shielded 

cable  (This  cable  may  be  purchased  at  almost 

all professional sound and lighting stores). Your 

cables should be made with a male and female 

XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained 

and cannot be split.

Figure 1

  H2O DMX IR  

 

                                        DMX Set Up

Содержание H20 DMX IR

Страница 1: ...uct names are trademarks or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building a...

Страница 2: ...installed in a place where it is out of the reach of people s grasp Introduction Thank you for purchasing the H2O DMX IR by ADJ Products LLC The H2O DMX IR is an improvement of the very popu lar H2O D...

Страница 3: ...or exhibits a marked change in performance H2O DMX IR Safety Precautions Power Supply The ADJ H2O DMX IR contains a automatic voltage switch which will auto sense the voltage when it is plugged into t...

Страница 4: ...to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connec...

Страница 5: ...u have found your desired show press ENTER then press and hold the MENU button for at least 3 seconds to acti vate After you have set your desired show it can be changed at any time using the UP or DO...

Страница 6: ...4 You can also make your settings to your desire and stay in the mode do not exit this mode and your settings will stay as you have made them Auto Test This function will run a self test program 1 Pr...

Страница 7: ...hout a controller In a Master Slave set up one unit will act as the controlling unit and the others will react to the controlling units programs Any unit can act as a Master or as a Slave 1 Using appr...

Страница 8: ...ut the fixture FULL ON This button is invalid for the fixture FADE GOBO Press this button to select your desired wave effect Use buttons 4 9 to adjust speed and direction See the chart below DIMMER an...

Страница 9: ...further instructions Con tinuing to use the unit may cause serious damage Trouble Shooting Listed below is a problem that you may encounter with a solution No light output from the unit 1 Be sure the...

Страница 10: ...its products without any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied w...

Отзывы: