Power Supply:

 Before plugging your unit in, be sure the source volt-

age  in  your  area  matches  the  required  voltage  for  your  ADJ  Entour 

Faze. The ADJ Entour Faze is available in a 120v and 240v version. 

Because line voltage may vary from venue to venue, you should be 

sure your unit voltage matches the wall outlet voltage before attempt-

ing to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Entour Faze can be controlled via DMX-512 protocol. The Entour 

Faze has 3 DMX channel modes, 1 channel, 2 channel, and 4 channel. 

The DMX address is set on the back panel. Your unit and your DMX 

controller  require  a  standard  3-pin  XLR  connector 

for data input and data output (Figure 1). We recom-

mend Accu-Cable DMX cables. If you are making 

your own cables, be sure to use standard 110-120 

Ohm shielded cable (This cable may be purchased 

at almost all pro lighting stores). Your cables should 

be made with a male and female XLR connector on 

either end of the cable. Also remember that DMX 

cable must be daisy chained and cannot be split.

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 O T

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 O T

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

 Entour Faze  

 

                           DMX Information

 Entour Faze  

 

                           DMX Information

Содержание ENTOUR FAZE

Страница 1: ...espective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or...

Страница 2: ...perate normally or exhibits a marked change in performance Entour Faze Safety Precautions ADJ Products LLC www adj com Entour Faze Instruction Manual Page 3 Introduction Congratulations you have just...

Страница 3: ...r that DMX cable must be daisy chained and cannot be split Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con...

Страница 4: ...Smoke Output H LED Display 4 Funtion Buttons I Control Socket Connection C D B N O E A F G J DMX 3 pin XLR Output K DMX 3 pin XLR Input L Manual Fog M Power ON OFF N Fuse O Electric Power Input P Saf...

Страница 5: ...ation setting and interval setting DOWN BUTTON Use this button to make adjustments to DMX addressing DMX channel mode duration setting and interval setting Entour Faze System Menu DMX Address DMX Mode...

Страница 6: ...he current software version will be displayed 2 2 Seconds after power is applied the unit will begin to warm up 3 After the machine has fully heated up the last function before power was shut off will...

Страница 7: ...controller to the unit 5 When 4 channel mode is selected after about 5 seconds the screen will change to the display shown below NOTE Duration and Interval setting is only available in 4 Channel mode...

Страница 8: ...through your machine Running anything other then water based fog juice will severly damage your machine Entour Faze Maintenance The fluid cannot get dirty Always make sure the cap is clean and the fo...

Страница 9: ...ll have no liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is...

Страница 10: ...PTION ml min 4 5ml min Max Output FLUID TYPE Water Based American DJ ECO Fog Juice DMX CHANNELS 3 DMX Channel Modes 1 2 4 DUTY CYCLE Not to exceed 6 hours turned on INCLUDED ACCESSORIES 3 Meter Wired...

Отзывы: