DMX Set Up

DMX-512:

DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication

between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the
controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the
DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a
DATA “OUT” terminal).

DMX Linking:

DMX is a language allowing all makes and models of different manufactures to be

linked together and operate from a single controller, as long as all fixtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the
shortest cable path possible. The order in which fixtures are connected in a DMX line does not
influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed
anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that
unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

The Encore Profile Pro WW can be controlled

via DMX-512 protocol. The Encore Profile Pro WW has multiple DMX channel modes. Your unit and
your DMX controller requires a 5-pin XLR connector for data input and data output. If you are making your
own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at
almost all pro lighting stores). Your cables should be made with a male and female XLR connector on
either end of the cable. Also remember that DMX cable must be daisy chained and cannot be split.

Special Note: Line Termination.

When longer runs of cable are used, you may need to use a terminator

on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected
between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female
XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ
part number Z-DMX/T) will decrease the possibilities of erratic behavior.

Содержание ENCORE PROFILE PRO WW

Страница 1: ...ENCORE PROFILE PRO WW User Instructions Shown with optional 36 Lens Kit Lens Kits sold separately...

Страница 2: ...tested and found to comply with the limits as per Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This d...

Страница 3: ...uidelines 7 Overview 8 Lens Gobo Holder Installation 9 Installation 10 System Menu 13 Multiple Unit Power Linking Dimmer Mode Chart 16 DMX Setup 17 DMX Addressing 18 DMX Channel Functions Values 19 Sp...

Страница 4: ...fety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Customer Support Contact ADJ Service for any product related service and supp...

Страница 5: ...son of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the so...

Страница 6: ...omer support team on our customer support number All packages returned to the service department not displaying a R A number on the outside of the package will be returned to the shipper Encore Profil...

Страница 7: ...N AND MOISTURE MINIMUM DISTANCE TO OBJECTS SURFACES MUST BE 6 6 FEET 2 METERS MAXIMUM TEMP OF EXTERNAL SURFACE 185 F 85 C MINIMUM DISTANCE OF INFLAMMABLE MATERIALS FROM THE SURFACE 1 6 FEET 0 5 METER...

Страница 8: ...rview Lens not included Blade Shutters Yoke Handle Mounting Yoke Focus Gobo Slot Cover LCD Menu Control Display ENTER Button UP Button MODE Button DOWN Button 5pin DMX OUT 5pin DMX In Power Out Power...

Страница 9: ...thumb screws of the lens kit into their respective gaskets and through the bar slots into the lens kit housing then tighten Gobo Holder To install Gobo Holder loosen the 2x thumb screws of Gobo Holde...

Страница 10: ...e is properly certified to safely hold the combined weight of the fixture s clamps cables and accessories Fixture ambient operating temperature range is 14 to 113 F 10 to 45 C Do not Use fixture under...

Страница 11: ...e fixture with an appropriately rated professional grade rigging clamp not included to the fixture yoke bracket center hole using an M12 screw and nut not included MAKE SURE THE CLAMP IS SECURELY ATTA...

Страница 12: ...wiring discharge lamps and LEDs This issue is not specific to ADJ lighting fixtures it is a common issue with lighting fixtures from all manufacturers Although there is no true way to fully prevent t...

Страница 13: ...ferent menu s with the UP DOWN and MENU buttons When you reach a field that requires adjusting press the ENTER button to access that field and use the UP and DOWN buttons to adjust the field Pressing...

Страница 14: ...MastSlav Starting DMX Address Shall display last active DMX value Master Slave Temp C F C F Dim Mode Standard Stage TV Architec Theatre Stage 2 Dim Spd 0 10s Dim Curve Linear Square Inv Squa S Curve...

Страница 15: ...de In this menu you are able to select your desired dimmer mode and adjust the dimming speed time Disp Set In this menu you are able to activate deactivate the display blackout and activate deactivate...

Страница 16: ...2040 2120 Theatre 1580 1940 2230 2280 Stage 2 0 1100 0 1660 0 255 0 255 Encore Profile Pro WW Multiple Unit Power Linking Encore Profile Pro WW Dimmer Mode Chart With this feature you can connect the...

Страница 17: ...fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX...

Страница 18: ...ol display on the fixture You can set the same starting address for all fixtures or a group of fixtures or set different addresses for each individual fixture Setting all fixtures to the same DMX addr...

Страница 19: ...t 096 127 Shutter OPEN LEDs ON 128 159 Pulse effect in sequences 160 191 Shutter OPEN LEDs ON 192 223 Random strobe effect slow to fast 224 255 Shutter OPEN LEDs ON 248 255 Open 4 Dim Modes 000 020 St...

Страница 20: ...42 1220 Hz LED Refresh Rate 043 043 1230 Hz LED Refresh Rate 044 044 1240 Hz LED Refresh Rate 045 045 1250 Hz LED Refresh Rate 046 046 1260 Hz LED Refresh Rate 047 047 1270 Hz LED Refresh Rate 048 048...

Страница 21: ...Refresh Rate 070 070 1500 Hz LED Refresh Rate 071 071 2500 Hz LED Refresh Rate 072 072 4000 Hz LED Refresh Rate 073 073 5000 Hz LED Refresh Rate 074 074 6000 Hz LED Refresh Rate 075 075 10K Hz LED Ref...

Страница 22: ...ut Locking Power Connector In Out With Wired Digital Communication Network SIZE WEIGHT Length 26 9 688mm Lens In Width 111 3 287mm Vertical Height 17 7 450mm Weight 20 0 lbs 9 1 kg ELECTRICAL THERMAL...

Страница 23: ...23 17 7in 450mm 12 7in 323mm 26 9in 683mm 1 0in 26mm 9 8in 250mm 1 7in 42mm 22 2in 563mm 7 9in 200mm 11 4in 289mm Encore Profile Pro WW Dimensions...

Страница 24: ...ncluded LENS KIT 5 LENS KIT 10 14 3in 362 0mm 14 1in 357mm 24 7in 626 5mm 14 5in 367 5mm 11 5in 293 0mm 5 3in 135 1mm 6 6in 167mm 5 1in 130mm 3 0in 76mm 11 9in 303 0mm 11 7in 298mm 13 8in 351 5mm 5 3i...

Страница 25: ...not included LENS KIT 14 8 7in 222 0mm 8 5in 217mm 10 7in 271 1mm 5 3in 135 1mm 9 0in 227 5mm 7 3in 184 5mm 6 6in 167mm 5 1in 130mm 3 0in 76mm 6 3in 159mm 6 8in 172 0mm 6 1in 154 2mm 6 6in 167mm 5 1i...

Страница 26: ...mensions Lens Kits are not included 10 0in 255 0mm 6 9in 175 0mm 7 5in 190 0mm 6 3in 161 0mm 14 7in 374 3mm 1 9in 48 6mm ZOOM LENS KIT 25 50 10 0in 255 0mm 6 9in 175 0mm 19 6in 496 8mm 1 9in 48 6mm 7...

Страница 27: ...ore Profile Pro WW Maintenance MAINTENANCE Regular inspections are recommended to ensure proper function and extended life There are no user serviceable parts inside this fixture please refer all othe...

Страница 28: ......

Отзывы: