Ppower Supply: The ADJ Encore FR50z contains an automatic voltage switch, which will automati-

cally sense the voltage when it is plugged into the power source. With this switch, there is no need 

to worry about the correct power voltage, and this unit can be plugged in anywhere. 

DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and 

controller manufacturers as a form of communication between intelligent fixtures and controllers. 

A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent 

as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals 

located on all DMX fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: DMX is a language allowing all makes and models of different manufacturers to be 

linked together and operate from a single controller, as long as all fixtures and the controller are DMX 

compliant. To ensure proper DMX data transmission, try to use the shortest cable path possible 

when linking several DMX fixtures. The order in which fixtures are connected in a DMX line does not 

influence the DMX addressing. For example, a fixture assigned a DMX address of 1 may be placed 

anywhere in a DMX line: at the beginning, at the end, or anywhere in the middle. Therefore, the first 

fixture controlled by the controller could be the last fixture in the chain. When a fixture is assigned 

a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no 

matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation): The Encore FR50z can be con-

trolled via DMX-512 protocol, and has 6 different DMX channel modes. The DMX address is set elec-

tronically using the controls on the rear panel of the unit. Your unit and your DMX controller require 

an approved DMX-512 110 Ohm Data cable for data input and data output (Figure 1). We recom-

mend AccuCable DMX cables. If you are making your own cables, be sure to use standard 110-120 

Ohm shielded cable (This cable be purchased at almost all professional sound and lighting stores). 

Your cables should be made with a male XLR connector at one end and a female XLR connector at 

the other. Also remember that DMX cable must be daisy chained and cannot be split.

Содержание ENC846

Страница 1: ...User Manual ENCORE FR50Z...

Страница 2: ...tained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this product Europe Energy Saving Notice Energy Saving...

Страница 3: ...utions 6 Layout 7 DMX Setup 8 System Menu 10 Operating Instructions 12 Primary Secondary Configuration Zoom Adjustment Knob 16 DMX Traits 17 Multi Unit Power Linking Dimmer Curve Chart 18 Barn Door At...

Страница 4: ...ual with the unit for future reference Customer Support ADJ provides a customer support line to provide set up help and to answer any ques tion that may arise during set up or initial operation ADJ PR...

Страница 5: ...anty you must provide a copy of your proof of purchase invoice You may obtain an R A number by contacting our customer support team on our customer support number All packages returned to the service...

Страница 6: ...d for indoor use only Use of this product outdoors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply co...

Страница 7: ...1 Zoom Adjustment Knob 2 Power In 3 3 Pin DMX In 4 3 Pin DMX Out 5 Power Out 6 Mode Button 7 USB Port 8 Enter Button 9 LCD Menu Control Display 10 Down Button 11 Up Button 12 Barn Door Secure Lock 13...

Страница 8: ...g several DMX fixtures The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX l...

Страница 9: ...unit to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is connected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR co...

Страница 10: ...de 1CH DMX channel mode selection 2CH 2 2CH 3CH 2 3CH 4CH MENU Function NO DMX Lost DMX Black Hold DMX lost status LCD Set Display On Off Display settings Key Lock On Off On1 Flash On Off Temp Celsius...

Страница 11: ...rent running time hours Total Tim Total running time hours Last Clea Last running time cleared hours Timer Pin On Off Clear runnung time password 050 Temp Info Temp Info Current LED tem perature Err I...

Страница 12: ...the currently selected DMX channel mode will be displayed 2 Use the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to save your selection 3 Please refer to the DMX Traits se...

Страница 13: ...the display until the display unlocks Unit Temperature With this function you can switch the temperature display between Celsius or Fahrenheit 1 Plug the fixture in and press the UP or DOWN buttons u...

Страница 14: ...switch between ON or OFF To reset the unit to factory settings select ON and press ENTER Press the MODE button to exit the submenu with no changes Time Infomation In this submenu you are able to check...

Страница 15: ...ayed Press the MODE button to exit Manual Dimmer Mode 1 Plug the fixture in and press the UP or DOWN buttons until Menu Manual is displayed then press ENTER 2 ManCtrl Dimmer will be displayed Press th...

Страница 16: ...is the input and the female XLR connector is the ouput The first unit in the chain primary will use the female XLR connector only and the last unit in the chain will use the male XLR connector only 2...

Страница 17: ...Fine 2 2 3 Strobe 000 031 Off 032 063 On 064 095 Variable Strobe slow to fast 096 127 On 128 159 Pulse Effect slow to fast 160 191 On 192 223 Random Strobe slow to fast 224 255 On 3 3 4 Dim Mode 000...

Страница 18: ...t sockets The maximum that can be connected is as follows 20 fixtures 120V 40 fixtures 240V After the maximum connected fixtures you will need to use a new power outlet NOTE USE CAUTION WHEN POWER LIN...

Страница 19: ...e the Gel Frame in from the top and into the 3 Grooves located closest to the unit 2 Slide the Barn Door in from the top and into the 3 Barn Door Grooves 3 Flip the lens lock back down into place to s...

Страница 20: ...20 DIMENSIONAL DRAWINGS...

Страница 21: ...uts and outputs are connected does affect the operation of the unit CLEANING Due to fog residue smoke and dust cleaning of the internal and external optical lenses must be carried out periodically to...

Страница 22: ...service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement th...

Страница 23: ...9 8 L x 9 4 W x 11 7 H 247 8mm L x 238 1mm W x 298 3mm H Colors Warm White DMX Channels 6 DMX Modes 1 2 2 2 3 2 3 4 channels Control RDM Remote Device Management Warranty 2 Year 730 Days Please Note S...

Страница 24: ......

Отзывы: