background image

9

I N S TA L L AT I O N

FLAMMABLE MATERIAL WARNING

Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics.

ELECTRICAL CONNECTIONS

A qualified electrician should be used for all electrical connections and/or installations.

USE CAUTION WHEN POWER LINKING FIXTURES OF OTHER MODEL TYPES, AS 

THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE 

MAX POWER OUTPUT ON THIS FIXTURE. CHECK SILK SCREEN FOR MAX AMPS.
MINIMUM DISTANCE TO OBJECTS/SURFACES IS 6.6 FEET (2 METERS).

MINIMUM DISTANCE OF INFLAMMABLE MATERIALS FROM THE SURFACE IS 1.6 

FEET (0.5 METER)

DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!

•  Fixture MUST be installed following all local, national, and country commercial electrical and con-

struction codes and regulations.

•  Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or placing 

the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine 

if the metal truss/structure or surface is properly certified to safely hold the combined weight of the 

fixture(s), clamps, cables, and accessories.

•  Ambient operating temperature range is 14°F to 113°F (-10°C to 45°C). Do not use operate the 

fixture when ambient temperature falls outside of this range!

•  Fixture(s) should be installed in areas outside walking paths, seating areas, or areas were unau-

thorized personnel might reach the fixture by hand.

•  NEVER stand directly below the fixture(s) when rigging, removing or servicing.

•  Overhead fixture installation must always be secured with a secondary safety attachment, such as 

an appropriately rated safety cable.

•  Allow approximately 60 minutes for the fixture to cool down before servicing.

RIGGING

Overhead rigging requires extensive experience, including calculating working load limits, 

installation material being used, and periodic safety inspection of all installation material and 

the fixture, among other skills. If you lack these qualifications, do not attempt the installation 

yourself. Improper installation can result in bodily injury.

Содержание ENC176

Страница 1: ...User Manual ENCORE PROFILE MINI WW ...

Страница 2: ...pment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and opera tion of this product Europe Energy Saving Notice Energy Saving Matters EuP 2009 125 EC Saving electric ene...

Страница 3: ...uidelines 7 Overview 8 Installation 9 Accessory Installation 13 Gobo 15 Operation 17 Remote Device Management RDM 18 Control Panel 19 System Menu 20 DMX Setup 22 DMX Traits 24 Dim Modes 27 Daisy Chain Power Linking Cleaning Maintenance 28 Dimensional Drawing 29 Specifications 32 Error Codes Accessory Information 33 ...

Страница 4: ...Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments or suggestions Parts To purchase parts online visit http parts adj com US http www adjparts eu EU ADJ SERVICE USA Monday Friday 8 00am to 4 30pm PST Voice 800 322 6337 Fax 323 582 2941 support adj com ADJ SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546 85 60 Fax 3...

Страница 5: ...es for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of ADJ Products LLC All products covered by this warranty were manufactured after August 15 2012 and bear identifying marks to that effect ...

Страница 6: ... E G I S T R AT I O N This fixture carries a 2 year limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompanied by a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R ...

Страница 7: ... TEMPERATURE RANGE IS 14 F TO 113 F 10 C TO 45 C DO NOT OPERATE THE DEVICE WHEN AMBIENT TEMPERATURE FALLS OUTSIDE OF THIS RANGE MINIMUM DISTANCE TO FLAMMABLE MATERIALS FROM THE SURFACE IS 1 6 FEET 0 5 METER DO NOT TOUCH the fixture housing during operation Turn OFF the power and allow approximately 60 minutes for the fixture to cool down before serving DO NOT shake fixture and avoid brute force when ...

Страница 8: ...8 O V E R V I E W Barrel Installation Thumb Screw Yoke Adjustment Knob Mounting Yoke Display Screen Service Port Mode Button Down Button Up Button Enter Button DMX In DMX Out Power Out Power In ...

Страница 9: ...ipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture s clamps cables and accessories Ambient operating temperature range is 14 F to 113 F 10 C to 45 C Do not use operate the fixture when ambient temperature falls outside of this range Fixture s should be installed in areas outside walking paths...

Страница 10: ...ed each accessory must also be secured using its own appropriately rated safety cable securely and independently looped around the fixture s mounting yoke as shown in the illustra tion below Please refer to the Accessory Installation section of this manual for detailed information regarding the installation process for these accessories SAFETY CABLE ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING...

Страница 11: ...he mounting yoke Tighten the nut onto the threaded bolt to secure the mounted device in place CAUTION MAKE SURE THAT THE TRIPOD LEGS AND ALL TELE SCOPING ELEMENTS OF THE TRIPOD STAND ARE LOCKED IN PLACE BEFORE INSTALLING THE DEVICE ATOP THE STAND POSITION THE TRIPOD STAND AND MOUNTED DE VICE ONLY ON FLAT STABLE SURFACES DEPLOY TRIPOD LEGS FULLY IN ORDER TO MAXIMIZE STABIL ITY ...

Страница 12: ...lters irises shutters motors belts wiring dis charge lamps and LEDs This issue is not unique to ADJ lighting fixtures it is a common issue with lighting fixtures from all manufacturers Although there is no true way to fully prevent this issue from happening the guide lines below can reduce the risk of any potential damage if followed Contact ADJ Service for more details DO NOT EXPOSE THE FIXTURE A...

Страница 13: ...ned with the thumbscrew hole on the lens frame Fig 1 Then insert and tighten the thumbscrew to secure the barrel in place Fig 2 Please note that the barrel requires its own separate safety cable when installed in a suspended setting 1 2 GEL FRAME To install the gel frame press the release on the retainer clip at the end of the barrel and flip the clip open Fig 1 Slide the gel frame into the slot a...

Страница 14: ...arndoors into the slot at the end of the barrel Fig 2 If the gel frame has already been installed then the barndoors should be installed over the gel frame the gel frame should be closer to the frame of the barrel Close the retainer slip to secure the barndoors in place Please note that the barndoors require their own separate safety cable when installed in a sus pended setting 1 2 ...

Страница 15: ...1 220 in 31mm 0 008 in 0 2mm Glass 1 555 in 39 5mm 1 220 in 31mm 0 039 in 1mm Image Diameter Outer Diameter Thickness GOBO HOLDER DIMENSIONS 3 642in 92 5mm Ø 1 2 9 9 i n Ø 3 3 m m 1 874in 47 6mm 1 630in 41 4mm 1 520in 38 6mm 0 063in 1 6mm Please note that gobo holder is compatible with E size gobos ...

Страница 16: ...f the gobo is facing the front of the gobo holder then re insert and tighten the screw to close the gobo holder Next locate the plate on the barrel near the safety cable loop that is held in place with two knobs Loosen that knobs and slide the plate forward to expose the gobo slot Fig 2 Insert the gobo holder into the gobo slot making sure that the front of the gobo holder is facing towards the fr...

Страница 17: ...zoom function on this fixture is adjusted manually using a sliding knob located on the side of the barrel as shown in the illustration below Push the sliding knob towards the front of the barrel to zoom out or backwards to zoom in Zoom Knob ...

Страница 18: ...INFORMATION RDM Code Device ID Model ID Personality IDs 0x1900 32000 FFFF 32 02Ch 1 03Ch 2 06Ch 3 Please be aware that not all RDM devices support all RDM features and therefore it is important to check beforehand to ensure that the equipment that you are considering includes all of the features that you require The following parameters are accessible in RDM on this device 0x0011 Proxied Device Co...

Страница 19: ...lection AUTO LOCK As configured from the factory the unit will automatically lock the display screen controls after 2 min utes of inactivity The inactivity period before the controls automatically lock can be adjusted in the System Menu by navigating to PERSONALITY DISPLAY AUTO LOCK To unlock the display screen controls simply press and hold the Mode button until the controls unlock SOFTWARE PORT ...

Страница 20: ...heatre Stage 2 Dim Speed 0 0s 10s Dim Curves Square Linear Square Inverse S Curve PWM Freq 900 1500Hz 2500Hz 4000Hz 5000Hz 6000Hz 10KHz 15KHz 20KHz 25KHz Default 1200Hz Display Screen Display Off 1min 9min Screen goes to sleep after pre set period of inactivity Auto Lock Off 10min Screen controls lock after pre set period of inactivity default 2min Flip Display Yes No Invert display orienta tion S...

Страница 21: ... Run hours since last reset Power On Time Reset Passcode 038 Reset Power On Tim Able Res hours Total Lamp Hours xxxxxx Hours Lamp on hours Fixture Temp Current xxx F xxx C Current fixture tempera ture Max Resettable xxx F xxx C Max fixture temperature since last reset Last Max Temp Re set Passcode 038 Reset Max Resettable temperature Software Version Vx xx S Y S T E M M E N U ...

Страница 22: ...en a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation This fixture can be controlled via DMX 512 protocol and features multiple DMX channel modes Your unit and your DMX controller require 5 pin XLR connectors for data input and data outpu...

Страница 23: ... fixture Setting all fixtures to the same DMX address will cause all fixtures to react in the same way In this case please note that changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will start to listen to the channel number you have set based on the quantity of DMX channels of each fixture That means chan...

Страница 24: ...nces 160 191 Shutter Open LEDs On 192 223 Random Strobe Effect slow to fast 224 255 Shutter Open LEDs On 4 Dim Modes 000 020 Default to unit setting 021 040 Standard 041 060 Stage 061 080 TV 081 100 Architectural 101 120 Theatre 121 140 Stage 2 Dimming Speed 141 0 1s 142 0 2s 143 0 3s 144 0 4s 145 0 5s 146 0 6s 147 0 7s 148 0 8s 149 0 9s 150 1 0s 151 1 5s 152 2 0s 153 3 0s 154 4 0s 155 5 0s 156 6 ...

Страница 25: ...Hz 011 900 Hz 012 910 Hz 013 920 Hz 014 930 Hz 015 940 Hz 016 950 Hz 017 960 Hz 018 970 Hz 019 980 Hz 020 990 Hz 021 1000 Hz 022 1010 Hz 023 1020 Hz 024 1030 Hz 025 1040 Hz 026 1050 Hz 027 1060 Hz 028 1070 Hz 029 1080 Hz 030 1090 Hz 031 1100 Hz 032 1110 Hz 033 1120 Hz 034 1130 Hz 035 1140 Hz 036 1150 Hz 037 1160 Hz 038 1170 Hz 039 1180 Hz 040 1190 Hz 041 1210 Hz 042 1220 Hz 043 1230 Hz CONTINUED O...

Страница 26: ...050 1300 Hz 051 1310 Hz 052 1320 Hz 053 1330 Hz 054 1340 Hz 055 1350 Hz 056 1360 Hz 057 1370 Hz 058 1380 Hz 059 1390 Hz 060 1400 Hz 061 1410 Hz 062 1420 Hz 063 1430 Hz 064 1440 Hz 065 1450 Hz 066 1460 Hz 067 1470 Hz 068 1480 Hz 069 1490 Hz 070 1500 Hz 071 2500 Hz 072 4000 Hz 073 5000 Hz 074 6000 Hz 075 10 KHz 076 15 KHz 077 20 KHz 078 25 KHz 079 255 No Function ...

Страница 27: ...1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Stage 2 0 1100 0 1660 Rise Time ms Down Time ms Rise Time ms Down Time ms Rise Time Down Time Dimming Curve Ramp Effect 0 sec Fade Time 1 sec Fade Time Output 0 100 Output 0 100 Output 0 100 Output 0 100 DMX DMX DMX DMX LINEAR SQUARE INVERSE SQUARE S CURVE ...

Страница 28: ...e months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tightened at all times Loose screws may fall out during normal operation resulting in damage or injury as larger parts could fall Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations in ...

Страница 29: ...29 D I M E N S I O N A L D R AW I N G S FIXTURE ONLY 6 260in 159mm 8 819in 224mm 5 394in 0 118 137mm 3 0 0 Ø 3 071in Ø 78mm 5 669in 144mm 10 866in 276mm ...

Страница 30: ...30 D I M E N S I O N A L D R AW I N G S 15 30 LENS INSTALLED Ø 0 5 1 2 i n Ø 1 3 m m Ø 2 378in Ø 60 4mm Ø 2 480in Ø 63mm 8 760in 222 5mm 6 024in 153mm ...

Страница 31: ...31 D I M E N S I O N A L D R AW I N G S 25 50 LENS INSTALLED Ø 2 378in Ø 60 4mm Ø 2 480in Ø 63mm Ø 0 5 1 2 i n Ø 1 3 m m 6 988in 177 5mm 6 024in 153mm ...

Страница 32: ...included Gobo s are sold separately CONTROL CONNECTIONS 3 DMX Channel Modes 2 3 6 Adjustable Refresh Rates 900 1500 25 000 Hz 4 Button Control Panel OLED Menu Display Locking 5pin XLR Connector In Out IP65 Locking Power In Out With Wired Digital Communication Network RDM Remote Device Management USB Service Port SIZE WEIGHT Length 6 03 153mm NO LENS Width 5 67 144mm Vertical Height 10 75 273mm Wei...

Страница 33: ... twist lock power link cable SIP126 5 ft IP65 male to female twist lock power link cable SIP139 10 ft IP65 male to female twist lock power link cable SIP152 16 ft IP65 male to female twist lock power link cable SIP165 25 ft IP65 male to female twist lock power link cable SIP178 50 ft IP65 male to female twist lock power link cable SIP191 100 ft IP65 male to female twist lock power link cable E R R...

Страница 34: ......

Отзывы: