A.D.J. Supply Europe B.V.
– www.americandj.eu – CRAZY POCKET 8 User Instructions Page 9
SYSTEM MENU (continued)
System Menu: When making adjustments press ENTER to confirm your setup then press and hold the
MENU button for at least 3 seconds. To exit without making any adjustments press the MENU button.
The display will lock after 30 seconds, press the MENU button for 3 seconds to unlock.
ADDR
- DMX Address Setting
.
1. Press the either the MENU, UP, or DOWN buttons until “
ADDR
” is displayed, press ENTER.
2. The current address will now be displayed and flashing. Press the UP or DOWN buttons to find your desired
address. Press ENTER to set your desired DMX address.
CHND
- This will let select your desired DMX channel mode.
1. Pre
ss the MENU button until “
CHND
” is displayed, press ENTER. The current DMX channel mode will be
displayed
2. Press the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to confirm and
exit.
SLND
- This will let you set unit as a master or slave in a master/slave configuration.
1. Press the MENU button until “
SLND
” is displayed, press ENTER. Either “
MAST
”, “
SL 1
”, or “
SL 2
” will be
displayed.
2. Press the UP or DOWN buttons until your desired setting is displayed, press ENTER to confirm.
Note:
In a Master/Slave configuration you can set one fixture to Master and then set the next fixture to “
SL 2
”,
the fixtures will now have contrast movement to each other.
SHND
- Show modes 1-4 (Factory programs). Show mode can run with or without sound active
mode active.
1. Press the MENU button until “
SHND
” is displayed, press ENTER.
2. “
Sh X
” will now be displayed, “
X
” representing a number between 1-4. Use the UP or DOWN buttons to find
your desired show.
3. When you have found your desired show press ENTER, then press and hold the MENU button for at least 3
seconds to activate.
DIND
- This will let select your desired dimmer curve.
1. Press the either the MENU button until
“
DIND
” is displayed, press ENTER. 1 of 5 dimmer curves will be
displayed. “STDA” (standard), “STGE” (stage), “TV” (TV), “ARAL” (theatrical), or “THAL” (Architectural).
2. Press the UP or DOWN buttons to find your desired dimmer curve and press ENTER to confirm and exit.
SOUN
- Sound Active mode.
1. Press the MENU button until “
SOUN
” is displayed, press ENTER.
2. The display will show either “
ON”
or
“OFF
”. Press the UP or DOWN buttons to select “
ON
” to activate
sound active mode, or “
OFF
” to deactivate sound active mode.
3. Press ENTER to confirm.
SENS
- In this mode you can adjust the sound sensitivity.
1. Press the MENU button until “
SENS
” is displayed, press ENTER.
2. A number between 0-100 will be displayed. Press the UP or DOWN buttons to adjust the sound sensitivity.
0 being the least sensitive, and 100 being the most sensitive.
3. When you have found your desired setting press ENTER to confirm.
DNST
- This mode can be used as a precaution mode, that in case the DMX signal is lost,
interrupted, or power is lost, the operating mode chosen in the setup is the running mode the fixture
will go into when the DMX signal is lost. You can also set this as the operating mode you would like
the unit to return to when power is applied.
1. Press the MENU button u
ntil “
DNST
” is displayed, and either “
MASL
”, “
BLND
”, or “
LAST
” will be displayed
beneath.