ADJ ALLEGRO Z6 Скачать руководство пользователя страница 16

ADJ Products, LLC  -  www.adj.com  - Allegro Z6 User Manual Page 15

  

Allegro Z6

                                                                                                 

System Menu

DMX SETTINGS

001-XXX

Tilt Movement Speed

DMX Lost Status

DMX Channel Mode 

Selection

DMX Addressing

17Ch / 37Ch

MENU

OPTIONS

DESCRIPTION

SUBMENU

Reverse Tilt Motion

DMX Address

DMX Channel Mode

No DMX Status

Hold Last / Blackout / Manual
Artnet / sACN / Disable

255.0.0.0

PERSONALITY

Status Settings

Display

Service

(PassCode = 50)

Tilt Invert: ON / OFF
Tilt Feedback: ON / OFF
Tilt Speed: Speed 1-4
Hibernation: Off / 01M~99M / 15M 

Display Invert: YES / NO
Screen Saver Delay: OFF~10 Minutes

Display Readout Inversion
Display Shutoff Time

Reverse Tilt Motion

Set Network Protocol

Enter Fixture’s MAC Address

Sleep Setting (No Activity)

2.1.1.1

Enter Fixture’s IP Address

Display Lock: ON / OFF

Display Lock

ETHERNET 

SETTINGS

Protocol
IP Address
Net Mask

0-32,767

Set ArtNet Universe

ArtNet Universe

sACN Universe: 00001-32000

Set sACN Universe

sACN Settings

sACN Priority: 0-255
ON / OFF (PassCode = 50)

Lock Ethernet Settings

Lock Ethernet Set

Set sACN Priority

Fan Settings

Base Fan Speed Setting

Head: Auto / High / Silent (Low)
Base: Auto / High / Silent (Low)

Head Fan Speed Setting

Dim Modes

Dimming Curve Modes

Dimming Speed

Standard / Stage / TV / Architectural / Theatre /

Stage2

Dim Speed: 0.1-0.9s ~ 1-10s

LED Refresh Rate

900Hz / 1000Hz / 1100Hz / 1200Hz / 1300Hz /

1400Hz / 1500Hz / 2500Hz / 6000Hz / 25000Hz LED Refresh Setting

Gamma

1.0 / 2.0 / 2.2 / 2.4 / 2.6 / 2.8

Gamma Brightness

Reset Motors

Reset All Motors: YES / NO

Tilt Reset: YES / NO
Zoom Reset: YES / NO

Reset All Motors
Reset the Tilt Motor
Reset the Zoom Motor

Effect Adjust - PassCode = 50

USB Port Power: ON / OFF
Update Software
Factory Restore: YES / NO - PassCode = 11

Calibration
USB Port Activation
Software Update
Restore Factory Settings

Pixel Flip

Standard / Flip

Set Pixel Flip Mode 

Содержание ALLEGRO Z6

Страница 1: ...User Instructions ALLEGRO Z6 OFFLINE SETTING...

Страница 2: ...Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interf...

Страница 3: ...ety Guidelines Overview Installation DMX Set Up DMX Addressing DMX Channel Modes Values System Menu Pixel Control Dimmer Curve Chart Dimensional Drawings Error Codes Fuse Replacement I Multiple Unit P...

Страница 4: ...used by professionally trained personnel only and is not suitable for private use Customer Support Contact ADJ Service for any product related service and support needs Also visit forums adj com with...

Страница 5: ...per included in the shipping carton If the unit is under warranty you must provide a copy of your proof of purchase invoice You may obtain a R A number by contacting our customer support team on our c...

Страница 6: ...s unit if it becomes damaged During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not l...

Страница 7: ...t operating lamp Rated max ambient temperature TA 40 Never open the housing without disconnecting the power supply rst Certain parts may still contain a voltage All safety instructions and warnings re...

Страница 8: ...handles for secondary attachment When installing the unit the trussing or area of installation must be able to hold 10 times the weight without any deformation When installing the unit must be secured...

Страница 9: ...ed on the base and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw NOTICE The suitable enviromental temperature for this lighting fixture i...

Страница 10: ...fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX...

Страница 11: ...fixture Setting all fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If...

Страница 12: ...0 255 BLUE 3 0 100 000 255 WHITE 3 0 100 000 255 5 6 7 8 9 10 11 12 13 14 RED 4 0 100 000 255 GREEN 4 0 100 000 255 BLUE 4 0 100 000 255 WHITE 4 0 100 000 255 RED 5 0 100 000 255 GREEN 5 0 100 000 255...

Страница 13: ...LORS MOVING COLORS Red Red Green Green Green Blue Blue Blue Red Red Red Green Blue Close 000 007 008 077 078 085 086 155 156 163 164 233 234 241 242 249 250 255 29 10 BACKGROUND COLORS STATIC COLORS R...

Страница 14: ...ec 5 0Sec 6 0Sec 7 0Sec 8 0Sec 9 0Sec 10Sec Default to Unit Setting 000 020 021 040 041 060 061 080 081 100 101 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141...

Страница 15: ...ns and access the sub menus with the UP and DOWN buttons When you reach a field that requires adjusting press the ENTER button to access that field and use the UP and DOWN buttons to adjust the field...

Страница 16: ...TTINGS Protocol IP Address Net Mask 0 32 767 Set ArtNet Universe ArtNet Universe sACN Universe 00001 32000 Set sACN Universe sACN Settings sACN Priority 0 255 ON OFF PassCode 50 Lock Ethernet Settings...

Страница 17: ...Running Time Power On Time XXXXXX Hours P On Time R XXXXXX Hours P On Time Reset PassCode 50 LED On Time XXXXXX Hours LED On Time R XXXXXX Hours LED On Time Reset PassCode 50 Fixture Temperatures Curr...

Страница 18: ...ED OFF 68 174 F 113 F 4 20 79 C 45 C 4 See Note 4 below 176 282 F 266 F 5 80 139 C 130 C 5 See Note 5 below Fixture Temp LED On Fixture Temp LED Off VX X Software Version Current Software Version INFO...

Страница 19: ...ill have the fixture stay in the last DMX setup Blackout This setting will have the fixture automatically go into stand by mode Manual This setting will go into the current manual control set up See M...

Страница 20: ...speed time LED REFRESH RATE In this submenu you are able to select your desired LED refresh rate GAMMA In this submenu you are able to select your desired gamma setting RESET MOTORS In this submenu y...

Страница 21: ...time is displayed This total LED ON time CANNOT be reset NOTE The displayed time represents the TOTAL LED ON time LED On Time R The CURRENT LED ON running time is displayed This running time may not...

Страница 22: ...ge 21 Allegro Z6 Pixel Control 1 6 5 4 3 2 CONNECTION SIDE DISPLAY SIDE 6 1 2 3 4 5 CONNECTION SIDE DISPLAY SIDE STANDARD FLIP This fixture features pixel control in 37 Channel DMX Mode See diagram be...

Страница 23: ...me ms 0 Sec 255 255 0 0 Standard default 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Stage 2 0 1100 0 1660 Rise Time ms Down T...

Страница 24: ...ADJ Products LLC www adj com Allegro Z6 User Manual Page 23 Allegro Z6 Dimensional Drawings 19 6 500mm 11 278mm 4 5 113mm 220...

Страница 25: ...Error 2 CPU C Error CPU C Error 3 CPU D Error CPU D Error 4 Tilt Reset Error Tilt Reset Error 5 Tilt Encoder Error Tilt Encoder Error 6 Zoom Reset Error Tilt Reset Error 7 Fan1 Errors Fan1 errors 8 F...

Страница 26: ...Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment...

Страница 27: ...absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair...

Страница 28: ...QUAD 4 in 1 RGBW LED s Working Position Any safe working position Power Draw 240W Fuse 5A Dimensions 19 6 L x 4 5 W x 11 H 500 x 113 x 278mm Weight 22lbs 10 kgs Colors RGBW Color Mixing DMX Channels...

Отзывы: