ADJ 818651024692 Скачать руководство пользователя страница 8

8

MAINTENANCE GUIDELINES

DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!

CLEANING 

Frequent cleaning is recommended to insure proper function, optimized light output, and an extended 

life.  The  frequency  of  cleaning  depends  on  the  environment  in  which  the  fixture  operates:  damp, 

smoky, or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics. 

Clean the external lens surface regularly with a soft cloth to avoid dirt/debris accumulation. 

NEVER use alcohol, solvents, or ammonia-based cleaners. 

MAINTENANCE 

Regular inspections are recommended to insure proper function and extended life.  There are no user 

serviceable parts inside this fixture. Please refer all other service issues to an authorized Elation ser-

vice technician. Should you need any spare parts, please order genuine parts from your local Elation 

dealer. 

Please refer to the following points during routine inspections: 

•  A detailed electrical check by an approved electrical engineer every three months, to make sure the 

circuit contacts are in good condition and prevent overheating.  

•  Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out 

during normal operation, resulting in damage or injury as larger parts could fall. 

•  Check for any deformations on the housing, color lenses, rigging hardware, and rigging points 

(ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the 

fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously 

injure a person(s). 

•  Electric power supply cables must not show any damage, material fatigue, or sediments. 

NEVER remove the ground prong from the power cable.

Содержание 818651024692

Страница 1: ...User Manual ENCORE BURST 200...

Страница 2: ...r unsafe insufficient and negligent assembly installation rigging and opera tion of this product ADJ USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 2650 323 532 2941 fax www adj com support ameri...

Страница 3: ...imited Warranty USA Only 5 Safety Guidelines 6 Maintenance Guidelines 8 Fixture Overview 9 Installation Instructions 10 System Menu 18 Dimming Curve 21 DMX Channel Functions and Values 22 Specificatio...

Страница 4: ...shipping carton in the trash Please recycle whenever possible CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments...

Страница 5: ...cts in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discreti...

Страница 6: ...ge and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF AS DOING SO WILL VOID YOUR MANUF...

Страница 7: ...wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is at least M10 x 25 mm and always install fixture with an appropriately rated safety cable...

Страница 8: ...ice technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electrical check by...

Страница 9: ...FIXTURE OVERVIEW 9 INCLUDED ITEMS Omega Bracket Yoke Bracket Kit Power Cable...

Страница 10: ...ture is NOT suitable for permanent outdoor and or marine environment installations Installing this fixture in permanent outdoor and or marine envi ronment installation may cause corrosion and or exces...

Страница 11: ...afely hold the combined weight of the fixture s clamps cables and accessories Maximum ambient operating temperature is 104 F 40 C Fixture s should be installed in areas outside walking paths seating a...

Страница 12: ...talla tion steps below INSTALLATION INSTRUCTIONS OMEGA BRACKET MUST BE USED WHEN CONNECTING FIXTURES TOGETHER 1 Attach the Omega Bracket to the fixture using 2 of the 4 included interlocking pins 2 To...

Страница 13: ...ON INSTRUCTIONS YOKE BRACKET FOR SINGLE FIXTURE INSTALLATION ONLY DO NOT USE WHEN CONNECTING MULTIPLE FIXTURES TOGETHER 1 Attach the Yoke Bracket to the fixture using the included hardware 2 Adjust th...

Страница 14: ...he first fixture as described on the previous page 2 Push out the spring loaded bracket on the top and bottom edges of each fixture then slide fix tures together and align the holes on both spring loa...

Страница 15: ...port 10x the total weight of the entire assembly 10 x combined weight of 10 fixtures and any associated hardware and accesso ries The first fixture in the chain must be attached to the structure using...

Страница 16: ...ed safety cable that can hold 10 times the weight of the fixture WHEN INSTALLING THE FIXTURE IN A SUSPENDED ENVIRONMENT ALWAYS ATTACH AN INDEPENDENT SAFETY CABLE BETWEEN THE TRUSS STRUC TURE AND THE F...

Страница 17: ...efault 0 degree position to 7 5 or 15 degrees UP and 7 5 and 15 0 degrees DOWN Simply push the LED lens array either UP or DOWN by hand until the desired angle is achieved The LED lens array movement...

Страница 18: ...ck of the fixture see image below To access the system menu press and hold the MENU button for 3 seconds The LCD Menu Control Display will shut OFF auto matically about 1 minute from the last button p...

Страница 19: ...he system will return to the main menu after 8 seconds of inactivity dINd Dimmer Curve Select dINd then press the ENTER button Use the DOWN and UP buttons to select from the fol lowing dimmer curves S...

Страница 20: ...note that strobe is only available when the device is set to 4 Channel Mode or 6 Channel Mode Press ENTER to confirm your selection then use the DOWN and UP buttons to adjust the value between 000 255...

Страница 21: ...21 DIMMING CURVE The fixture includes 6 different dimming curve modes which can selected from either the system menu or via DMX The graph below provides details on each dimming curve mode...

Страница 22: ...Intensity 0 100 5 000 255 Master Dimmer Intensity Fine 3 3 Shutter Strobe 000 031 LED Off 032 063 LED On 064 095 Strobe Effect slow to fast 096 127 LED On 128 159 Strobe Pulse Effect in Sequences slo...

Страница 23: ...ter ference received including interference that may cause undesired operation FCC RADIO FREQUENCY INTERFERENCE WARNINGS INSTRUCTIONS This product has been tested and found to comply with the limits a...

Страница 24: ...24 DIMENSIONAL DRAWINGS...

Страница 25: ...25 DIMENSIONAL DRAWINGS...

Страница 26: ......

Отзывы: