ADJ 818651024692 Скачать руководство пользователя страница 20

20

SYSTEM MENU

FAeq: Dimming Frequency.

Select “FAeq,” then press the ENTER button. Use the DOWN and UP buttons to scroll through the 

available frequency settings (900 Hz, 1000 Hz, 1100 Hz, 1200 Hz, 1300 Hz, 1400 Hz, 1500 Hz, 2500 

Hz, 4000 Hz, 5000 Hz, 10000 Hz, 15000 Hz, 20000 Hz, or 25000 Hz). Press ENTER to confirm your 

selection, or press MENU to exit without making changes.

gANN: Gamma Correction.

Select “gANN,” and press the ENTER button. Use the DOWN and UP buttons to scross through the 

available gamma correction settings (No, 2.0, 2.2, 2.4, 2.6, or 2.8). Press ENTER to confirm your 

selection, or press MENU to exit without making changes. Please note that the 2.6 gamma cor-

rection setting was added with software update version 1.3.

dISP: Display Invert.

Select “dISP,” and press the ENTER button. Use the DOWN and UP buttons to scroll between 

“dISP” (normal orientation) or “dSIP” (inverted orientation). Press ENTER to confirm your selection, 

or press MENU to exit without making changes.

NAnd: Manual Mode.

Select “NAnd,” and press the ENTER button. Use the DOWN and UP buttons to select the bright-

ness (dxxx) or strobe (Sxxx). Please note that strobe is only available when the device is set to 

4-Channel Mode or 6-Channel Mode. Press ENTER to confirm your selection, then use the DOWN 

and UP buttons to adjust the value between 000 - 255. Press ENTER again to confirm your selec-

tion, or press MENU to exit without making changes.

teSt: Auto Test.

Select “teSt,” and press the ENTER button. The unit will now run a built-in self-test program. Press 

the MENU button to return to the main menu, or wait ten seconds for the system to automatically 

return to the main menu.

tENP: Temperature Display.

Select “tENP,” and press the ENTER button. The device will now display the current temperature 

reading of the device. Press MENU to return to the main menu.

FhrS: Fixture Hours.

Select “FhrS,” and press the ENTER button. The device will now display the number of run time 

hours that have been logged. Press MENU to return to the main menu.

ver: Software Version.

Select “ver,” and press the ENTER button. The device will now display the current software version 

of the unit. Press the MENU button to return to the main menu.

dEF: Factory Setting.

Select “dEF,” and press the ENTER button. Use the DOWN and UP button to scroll to either “YeS” to 

restore the device to factory settings, or “no” to exit without making changes. Press the ENTER but-

ton to confirm your selection.

Содержание 818651024692

Страница 1: ...User Manual ENCORE BURST 200...

Страница 2: ...r unsafe insufficient and negligent assembly installation rigging and opera tion of this product ADJ USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 2650 323 532 2941 fax www adj com support ameri...

Страница 3: ...imited Warranty USA Only 5 Safety Guidelines 6 Maintenance Guidelines 8 Fixture Overview 9 Installation Instructions 10 System Menu 18 Dimming Curve 21 DMX Channel Functions and Values 22 Specificatio...

Страница 4: ...shipping carton in the trash Please recycle whenever possible CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs Also visit forums adj com with questions comments...

Страница 5: ...cts in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discreti...

Страница 6: ...ge and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF AS DOING SO WILL VOID YOUR MANUF...

Страница 7: ...wall for proper cooling When installing fixture in a suspended environment always use mounting hardware that is at least M10 x 25 mm and always install fixture with an appropriately rated safety cable...

Страница 8: ...ice technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electrical check by...

Страница 9: ...FIXTURE OVERVIEW 9 INCLUDED ITEMS Omega Bracket Yoke Bracket Kit Power Cable...

Страница 10: ...ture is NOT suitable for permanent outdoor and or marine environment installations Installing this fixture in permanent outdoor and or marine envi ronment installation may cause corrosion and or exces...

Страница 11: ...afely hold the combined weight of the fixture s clamps cables and accessories Maximum ambient operating temperature is 104 F 40 C Fixture s should be installed in areas outside walking paths seating a...

Страница 12: ...talla tion steps below INSTALLATION INSTRUCTIONS OMEGA BRACKET MUST BE USED WHEN CONNECTING FIXTURES TOGETHER 1 Attach the Omega Bracket to the fixture using 2 of the 4 included interlocking pins 2 To...

Страница 13: ...ON INSTRUCTIONS YOKE BRACKET FOR SINGLE FIXTURE INSTALLATION ONLY DO NOT USE WHEN CONNECTING MULTIPLE FIXTURES TOGETHER 1 Attach the Yoke Bracket to the fixture using the included hardware 2 Adjust th...

Страница 14: ...he first fixture as described on the previous page 2 Push out the spring loaded bracket on the top and bottom edges of each fixture then slide fix tures together and align the holes on both spring loa...

Страница 15: ...port 10x the total weight of the entire assembly 10 x combined weight of 10 fixtures and any associated hardware and accesso ries The first fixture in the chain must be attached to the structure using...

Страница 16: ...ed safety cable that can hold 10 times the weight of the fixture WHEN INSTALLING THE FIXTURE IN A SUSPENDED ENVIRONMENT ALWAYS ATTACH AN INDEPENDENT SAFETY CABLE BETWEEN THE TRUSS STRUC TURE AND THE F...

Страница 17: ...efault 0 degree position to 7 5 or 15 degrees UP and 7 5 and 15 0 degrees DOWN Simply push the LED lens array either UP or DOWN by hand until the desired angle is achieved The LED lens array movement...

Страница 18: ...ck of the fixture see image below To access the system menu press and hold the MENU button for 3 seconds The LCD Menu Control Display will shut OFF auto matically about 1 minute from the last button p...

Страница 19: ...he system will return to the main menu after 8 seconds of inactivity dINd Dimmer Curve Select dINd then press the ENTER button Use the DOWN and UP buttons to select from the fol lowing dimmer curves S...

Страница 20: ...note that strobe is only available when the device is set to 4 Channel Mode or 6 Channel Mode Press ENTER to confirm your selection then use the DOWN and UP buttons to adjust the value between 000 255...

Страница 21: ...21 DIMMING CURVE The fixture includes 6 different dimming curve modes which can selected from either the system menu or via DMX The graph below provides details on each dimming curve mode...

Страница 22: ...Intensity 0 100 5 000 255 Master Dimmer Intensity Fine 3 3 Shutter Strobe 000 031 LED Off 032 063 LED On 064 095 Strobe Effect slow to fast 096 127 LED On 128 159 Strobe Pulse Effect in Sequences slo...

Страница 23: ...ter ference received including interference that may cause undesired operation FCC RADIO FREQUENCY INTERFERENCE WARNINGS INSTRUCTIONS This product has been tested and found to comply with the limits a...

Страница 24: ...24 DIMENSIONAL DRAWINGS...

Страница 25: ...25 DIMENSIONAL DRAWINGS...

Страница 26: ......

Отзывы: