ADJ 1226100361 Скачать руководство пользователя страница 16

ADJ Products, LLC  -  www.adj.com  - 12P Hex IP User Manual Page 15

12P Hex IP

System Menu

Update Wait

… 

ADJ
V1.07

Set ADDR

 

001

 

001 -506 

 

CH06 

 

6/7/8/13

 

Dim Mode

Standard 

Standard/Stage/TV Architec /Theatre

 

NO DMX

 

Hold 

Hold /Blackout/ Program

 

 

AUTO RUN 

FQN: 01 

01~99

 

 

1. STATC 

CL: R

R/G/B/RG/GB/RB/RGB/BLAC

 

STR  000-255 

 

Macros 

00 

00

 

~6

4

 

 

LCD.Set

Backlight

 

Key Lock 

05~60m

 

ON/ON1/OFF

 

DisFlash 

ON/OFF

 

DFSET 
OFF 

ON/OFF 

 

TEMP 
Fahren

Fahren 
Celsius

Settings
WhiteBal

Red

000~255

 

Green

000~255

 

Blue

000~255

 

White

000~255

 

Amber

000~255

 

UV

000~255  

White Balance Setting

 

Fre_hz  

900 

900 /1000/1100/1200/1300/1400/1500/2500/4000/50

00/10k /15k /20k /25k

 

 

Linear/Square/Inv. Squa/S-Curve

 

 

Info
TimeInfo

TimeInfo Current 
TimeInfo TotalTim
TimeInfo LastClea

TimeInfo TimerPIN

Current Running Time (Hours)
Total Time (Hours)

Last Time The Running Time
Was Cleared (Hours)

Clear 0 Password:

Password=050

Total Time Clear 0:

Password=060

Info
TempInfo

TempInfo
XXX

Info
Model Inf
Info
Software

V1.03

Info
ErrorInf

None

Slave

ManCtrlDimmer 000~

ManCtrlRed    000~255

ManCtrlGreen  000~255

ManCtrlBlue   000~255

ManCtrlWhite  000~255

ManCtrlAmber  000~255

ManCtrlPurple 000~255

ManCtrlStrobe 000~255

Display 

  Menu

Menu

 Set ADDR

Menu

  User Mode

Menu

Function

Menu

      Info

Menu

     Slave

Menu

   Manual

Default Reset

/

MENU           SUB MENU        OPTIONS/VALUES (DEFAULT SHADED)

DESCRIPTION

255

DMX Addressing

DMX Channel Modes

Dimmer Mode Setting

DMX Lost Setting

Auto Run Programs

Static Color Mode

Color Macro Mode

Temperature Display

Setting

LCD Display Settings

Set Dimming Curve

Set LED Refresh 

Frequency Rate 

Model Name

Current Software Version

Current Running

Temperature

Error Information

Slave Setting

Manual Control

DimCurve

Software Version

> V1.07

Содержание 1226100361

Страница 1: ...User Instructions 12P HEX IP 4 0 1 0 7 6 5...

Страница 2: ...Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cau...

Страница 3: ...recautions IP Notice Layout DMX Set Up DMX Addressing DMX Channel Modes Color Macro Chart System Menu Operating Instructions Primary Secondary Configuration Dimmer Mode Chart I Dimmer Curve Chart Dime...

Страница 4: ...ontain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Customer Support Contact ADJ Service for any product relat...

Страница 5: ...ing a mounting clamp not provided affixing it to the mounting bracket that is provided with the unit Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always...

Страница 6: ...s unit if it becomes damaged During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not l...

Страница 7: ...KIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet 3 3m DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INST...

Страница 8: ...as been designed and tested to protect against the ingress of dust 6 and low pressure water jets from any direction 5 M A R I N E C O A S T A L E N V I R O N M E N T I N S T A L L A T I O N S Please n...

Страница 9: ...oducts LLC www adj com 12P Hex IP User Manual Page 8 12P Hex IP Layout LCD Screen Mode Button Up Button Down Button Enter Button IP65 Locking Power Connection In Out IP65 Locking 5 Pin XLR Connector I...

Страница 10: ...irements For DMX Operation The 12P Hex IP can be controlled via DMX 512 protocol The 12P Hex IP has 4 DMX channel modes The DMX address is set on the back panel of the 12P Hex IP Your unit and your DM...

Страница 11: ...ll fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fix...

Страница 12: ...Auto Program Speed Auto Program Fade LED On Strobe Slow Fast LED On Strobe Pulse Slow Fast LED On Random Strobe 0 31 32 63 64 95 96 127 128 159 160 191 192 223 224 255 No Function Program 1 Program 2...

Страница 13: ...50 90 255 90 Color19 73 76 100 77 255 77 Color20 77 80 77 100 255 77 Color21 81 84 67 148 255 67 Color22 85 88 77 195 255 77 Color23 89 92 77 234 255 77 Color24 93 96 158 255 144 144 Color25 97 100 25...

Страница 14: ...0 Color48 189 192 52 148 209 0 Color49 193 196 0 46 35 0 Color50 197 200 8 107 222 0 Color51 201 204 107 156 231 0 Color52 205 208 165 198 247 0 Color53 209 212 0 83 115 0 Color54 213 216 0 97 166 0 C...

Страница 15: ...re_hz 900 900 1000 1100 1200 1300 1400 1500 2500 4000 50 00 10k 15k 20k 25k Gamma 2 0 2 0 2 2 2 4 2 8 Info TimeInfo TimeInfo Current TimeInfo TotalTim TimeInfo LastClea TimeInfo TimerPIN Current Runni...

Страница 16: ...g Fre_hz 900 900 1000 1100 1200 1300 1400 1500 2500 4000 50 00 10k 15k 20k 25k Linear Square Inv Squa S Curve Info TimeInfo TimeInfo Current TimeInfo TotalTim TimeInfo LastClea TimeInfo TimerPIN Curre...

Страница 17: ...Time Hours Last Time The Running Time Was Cleared Hours Clear 0 Password Password 050 Total Time Clear 0 Password 060 Info TempInfo TempInfo XXX Info Model Inf Info Software V1 03 Info ErrorInf None S...

Страница 18: ...m Please see the Dimmer Mode Chart on page 22 to see the settings and their respective beginning and ending fade times DMX State This mode is used as a precaution mode that in case the DMX signal is l...

Страница 19: ...There are 64 colors to choose from Find your desired color using the UP and DOWN buttons 4 Once you have found your desired color press ENTER LCD Display Settings 1 Plug the fixture in and press the...

Страница 20: ...ress ENTER Frequency Setting With this function you can adjust the dimming frequency 1 Plug the fixture in and press the MODE button and press the UP or DOWN buttons until Menu Function is displayed a...

Страница 21: ...to make your own desired color 1 Plug the fixture in and press the MODE button and press the UP or DOWN buttons until Menu Manual is displayed and press ENTER 2 Press the UP or DOWN buttons to scroll...

Страница 22: ...80 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Dimming Mode Ramp Effect Rise Time Down Time 0 sec Fade Time 1 sec Fade Time Rise Time ms Down Ti...

Страница 23: ...LC www adj com 12P Hex IP User Manual Page 22 12P Hex IP Dimensional Drawing 10 40 264 1mm 11 73 298mm 10 65 270 5mm 6 64 168 7mm 2 9 73 6mm 10 65 270 6mm 6 73 170 8mm 1 38 35mm 1 62 41mm 7 85 199 5mm...

Страница 24: ...optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry...

Страница 25: ...absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair...

Страница 26: ...10 40 L x 11 73 W x 7 85 H 264 1 x 298 x 199 5mm Colors RGBWA UV Color Mixing DMX Channels 4 DMX Modes 6 Channel Mode 7 Channel Mode 8 Channel Mode 13 Channel Mode Warranty 2 Year 730 days Please Note...

Отзывы: