12P Hex IP

Color Macro Chart

Color No. 

DMX 
VALUE 

RGBWA+UV COLOR INTENSITY

 

RED 

GREEN 

BLUE 

WHITE

  OFF

Color1 

1-4

80 

255 

234 

80 

Color2 

5-8

80 

255 

164 

80 

Color3 

9-12

77 

255 

112 

77 

Color4 

13-16

117 

255 

83 

83 

Color5

17-20

160 

255 

77 

77 

Color6 

21-24

223 

255 

83 

83 

Color7 

25-28

255 

243 

77 

77 

Color8 

29-32

255 

200 

74 

74 

Color9

33-36

255 

166 

77 

77 

Color10 

37-40

255 

125 

74 

74 

Color11 

41-44

255 

97 

77 

74 

Color12 

45-48

255 

71 

77 

71 

Color13 

49-52

255 

83 

134 

83 

Color14 

53-56

255 

93 

182 

93 

Color15 

57-60

255 

96 

236 

96 

Color16 

61-64

238 

93 

255 

93 

Color17 

65-68

196 

87 

255 

87 

Color18 

69-72

150 

90 

255 

90 

Color19 

73-76

100 

77 

255 

77 

Color20 

77-80

77 

100 

255 

77 

Color21 

81-84

67 

148 

255 

67 

Color22 

85-88

77 

195 

255 

77 

Color23 

89-92

77 

234 

255 

77 

Color24 

93-96

158 

255 

144 

144 

Color25 

97-100

255 

251 

153 

153 

Color26 

101-104

255 

175 

147 

147 

Color27 

105-108

255 

138 

186 

138 

Color28 

109-112

255 

147 

251 

147 

Color29 

113-116

151 

138 

255 

138 

Color30 

117-120

100 

138 

255 

138 

Color31 

121-124

138 

169 

255 

138 

Color32 

125-128

255 

255 

255 

255 

Color No.

DMX

VALUE

RED

GREEN

BLUE

WHITE

Color33

129-132

255

206

143

0

Color34

133-136

254

177

153

0

Color35

137-140

254

192

138

0

Color36

141-144

254

165

98

0

Color37

145-148

254

121

0

0

Color38

149-152

176

17

0

0

Color39

153-156

96

0

11

0

Color40

157-160

234

139

171

0

Color41

161-164

224

5

97

0

Color42

165-168

175

77

173

0

Color43

169-172

119

130

199

0

Color44

173-176

147

164

212

0

Color45

177-180

88

2

163

0

Color46

181-184

0

38

86

0

Color47

185-188

0

142

208

0

Color48

189-192

52

148

209

0

Color49

193-196

0

 46

 35

0

Color50

197-200

8

107

222

0

Color51

201-204

107

156

231

0

Color52

205-208

165

198

247

0

Color53

209-212

0

83

115

0

Color54

213-216

0

97

166

0

Color55

217-220

1

100

167

0

Color56

221-224

0

40

86

0

Color57

225-228

209

219

182

0

Color58

229-232

42

165

85

0

Color59

233-236

255

 0

 0

0

Color60

237-240

0

255

  0

0

Color61

241-244

  0

  0 

255

0

Color62

245-248

  0 

  0

  0

255

Color63

249-252

0

0

  0

0

Color64

253-255

  0

  0

  0

0

 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0 
 0
 0
 0
 0
 0
 0
 0
 0
 0

  0
  0
  0
  0
  0
  0
  0
  0
  0

 0
 0
 0 
 0 
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0

  0
  0
  0
  0
  0
  0
  0
  0
  0

AMBER 

UV

RGBWA+UV COLOR INTENSITY

0
0
0

 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0 
 0
 0
 0
 0
 0
 0
 0
 0
 0

  0
  0
  0
  0
  0
  0
  0
255

0
0
0

 0 
 0 
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0
 0

  0
  0
  0
  0
  0
  0

 255

  0

AMBER

UV

Содержание 1226100361

Страница 1: ...User Instructions 12P HEX IP 4 0 1 0 7 6 5...

Страница 2: ...Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cau...

Страница 3: ...recautions IP Notice Layout DMX Set Up DMX Addressing DMX Channel Modes Color Macro Chart System Menu Operating Instructions Primary Secondary Configuration Dimmer Mode Chart I Dimmer Curve Chart Dime...

Страница 4: ...ontain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Customer Support Contact ADJ Service for any product relat...

Страница 5: ...ing a mounting clamp not provided affixing it to the mounting bracket that is provided with the unit Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always...

Страница 6: ...s unit if it becomes damaged During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not l...

Страница 7: ...KIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet 3 3m DO NOT OPERATE FIXTURE WITH DAMAGED OR MISSING EXTERNAL COVER DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INST...

Страница 8: ...as been designed and tested to protect against the ingress of dust 6 and low pressure water jets from any direction 5 M A R I N E C O A S T A L E N V I R O N M E N T I N S T A L L A T I O N S Please n...

Страница 9: ...oducts LLC www adj com 12P Hex IP User Manual Page 8 12P Hex IP Layout LCD Screen Mode Button Up Button Down Button Enter Button IP65 Locking Power Connection In Out IP65 Locking 5 Pin XLR Connector I...

Страница 10: ...irements For DMX Operation The 12P Hex IP can be controlled via DMX 512 protocol The 12P Hex IP has 4 DMX channel modes The DMX address is set on the back panel of the 12P Hex IP Your unit and your DM...

Страница 11: ...ll fixtures to the same DMX address will cause all fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fix...

Страница 12: ...Auto Program Speed Auto Program Fade LED On Strobe Slow Fast LED On Strobe Pulse Slow Fast LED On Random Strobe 0 31 32 63 64 95 96 127 128 159 160 191 192 223 224 255 No Function Program 1 Program 2...

Страница 13: ...50 90 255 90 Color19 73 76 100 77 255 77 Color20 77 80 77 100 255 77 Color21 81 84 67 148 255 67 Color22 85 88 77 195 255 77 Color23 89 92 77 234 255 77 Color24 93 96 158 255 144 144 Color25 97 100 25...

Страница 14: ...0 Color48 189 192 52 148 209 0 Color49 193 196 0 46 35 0 Color50 197 200 8 107 222 0 Color51 201 204 107 156 231 0 Color52 205 208 165 198 247 0 Color53 209 212 0 83 115 0 Color54 213 216 0 97 166 0 C...

Страница 15: ...re_hz 900 900 1000 1100 1200 1300 1400 1500 2500 4000 50 00 10k 15k 20k 25k Gamma 2 0 2 0 2 2 2 4 2 8 Info TimeInfo TimeInfo Current TimeInfo TotalTim TimeInfo LastClea TimeInfo TimerPIN Current Runni...

Страница 16: ...g Fre_hz 900 900 1000 1100 1200 1300 1400 1500 2500 4000 50 00 10k 15k 20k 25k Linear Square Inv Squa S Curve Info TimeInfo TimeInfo Current TimeInfo TotalTim TimeInfo LastClea TimeInfo TimerPIN Curre...

Страница 17: ...Time Hours Last Time The Running Time Was Cleared Hours Clear 0 Password Password 050 Total Time Clear 0 Password 060 Info TempInfo TempInfo XXX Info Model Inf Info Software V1 03 Info ErrorInf None S...

Страница 18: ...m Please see the Dimmer Mode Chart on page 22 to see the settings and their respective beginning and ending fade times DMX State This mode is used as a precaution mode that in case the DMX signal is l...

Страница 19: ...There are 64 colors to choose from Find your desired color using the UP and DOWN buttons 4 Once you have found your desired color press ENTER LCD Display Settings 1 Plug the fixture in and press the...

Страница 20: ...ress ENTER Frequency Setting With this function you can adjust the dimming frequency 1 Plug the fixture in and press the MODE button and press the UP or DOWN buttons until Menu Function is displayed a...

Страница 21: ...to make your own desired color 1 Plug the fixture in and press the MODE button and press the UP or DOWN buttons until Menu Manual is displayed and press ENTER 2 Press the UP or DOWN buttons to scroll...

Страница 22: ...80 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Dimming Mode Ramp Effect Rise Time Down Time 0 sec Fade Time 1 sec Fade Time Rise Time ms Down Ti...

Страница 23: ...LC www adj com 12P Hex IP User Manual Page 22 12P Hex IP Dimensional Drawing 10 40 264 1mm 11 73 298mm 10 65 270 5mm 6 64 168 7mm 2 9 73 6mm 10 65 270 6mm 6 73 170 8mm 1 38 35mm 1 62 41mm 7 85 199 5mm...

Страница 24: ...optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry...

Страница 25: ...absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair...

Страница 26: ...10 40 L x 11 73 W x 7 85 H 264 1 x 298 x 199 5mm Colors RGBWA UV Color Mixing DMX Channels 4 DMX Modes 6 Channel Mode 7 Channel Mode 8 Channel Mode 13 Channel Mode Warranty 2 Year 730 days Please Note...

Отзывы: