  Inlet port pressure analog display

2

  Control and menu selection indicators (ON when activated)

3

  Auto-calibration START/ABORT control key

4

  Sniffing mode ON/OFF control key

5

  Auto-zero ON/OFF control key

6

  Cycle START/STOP control key

7

  Control keys (4 keys)

8

  Standby ON/OFF indicator

9

  Evacuation ON/OFF indicator

10

  Test ON/OFF indicator

11

  Helium signal analogic display

12

  Helium signal analogic scale ON/OFF indicator

13

  Helium signal Zero scale ON/OFF indicator

14

  Correction factor COR indicator (applied to digital display)

15

  Units of measurement selection

16

  Helium signal digital display

17

  Menu display (4 lines)

18

  Spectro pressure analog display

19

  Modification access keys (4 keys)

20

  RESET: next display/parameter circular function

21/22

 

Plus or minus value adjustment, parameter 

selection, audio volume adjustment keys

23

  NEXT of previously displayed values (cancels tempo-

rary inputs)

24

  Menu selection access key (4 keys)

25

  SET POINT menu selection key

26

  SPECTRO calibration and analyzer cell configuration 

menu selection key

27

  MAINTENANCE menu selection key

28

  OTHER menus selection key (test mode selection, 

inlet VENT selection, date/time)

29

  Remote control connection: 

connect if before swit-

ching on the detector 

30

  Graphic interface selection key

31

  Color touch screen

4

AUTO CAL

ZERO

CYCLE

SNIFFER

SET POINTS

SPECTRO

MAINTENANCE

OTHER

10

-12

10

-11

10

-10

10

-9

10

-8

10

-7

10

-6

10

-5

10

-4

10

-3

10

-2

COR

mbar.l/s

STDBY

LEAK RATE

EVAC

TEST

Pa.m

3

/s

Torr.l/s

11

17

25

26

27

14

15

20

22

23

21

19

24

28

30

31

16

29

18

1

2

10

9

8

13

12

3

4

5

6

7

Setting and maintenance part

Operation part

Operator interface ASM GRAPH/GRAPH D

Содержание ASM 142

Страница 1: ... GRAPH D Detector connections ASM 142 142 D Operator interface ASM GRAPH GRAPH D Operator interface Start up User interface level Test cycles Helium signal analog scale display Audio alarm Zero function References refer to a specific chapter of the Operating manual For further information please refer to Operating manual supplied with your unit 9 10 11 Condended Manual ...

Страница 2: ...ft side Right side Printer interface headphone loudspeaker option RS232 interface option I O interface option Quick connector exhaust Long distance sniffer quick disconnect Neutral gas purge ASM 142 D and ASM GRAPH D only Detector connections ...

Страница 3: ...lay 12 Helium signal analogic scale ON OFF indicator 13 Helium signal Zero scale ON OFF indicator 14 Correction factor COR indicator applied to digital display 15 Units ON OFF indicator 16 Helium signal digital display 17 Alphanumeric display 4 lines x 20 characters 18 Parameter function keys 1 key per display line 19 Modification access keys 4 keys 20 NEXT next display parameter circular function...

Страница 4: ... parameter circular function 21 22 Plus or minus value adjustment parameter selection audio volume adjustment keys 23 NEXT of previously displayed values cancels tempo rary inputs 24 Menu selection access key 4 keys 25 SET POINT menu selection key 26 SPECTRO calibration and analyzer cell configuration menu selection key 27 MAINTENANCE menu selection key 28 OTHER menus selection key test mode selec...

Страница 5: ...he unit please fill up the roughing pump with oil as indicated in the Operating manual E 750 CAUTION User interface level 1 2 3 4 Setting and maintenance part User part LEVEL This level has very limited information on the alphanumeric display LCD This level is generally selected for production types of applications No access to control keys Cycle key included LEVEL This level allows the operator t...

Страница 6: ...STDBY STDBY EVAC EVAC EVAC EVAC TEST TEST SNIFFER SNIFFER SNIFFER SNIFFER CYCLE TEST TEST STDBY STDBY Starting a cycle Ending a cycle Starting Sniffing test mode Ending Sniffing test mode 1 As soon as the inlet pressure reaches 10 mbar 7 5 torr the unit goes in gross leak test mode or when the pressure has reached 5 10 1 mbar 0 37 torr the unit goes in fine leak test mode F1 F3 F2 F4 READY FOR CYC...

Страница 7: ...F2 F4 10 mbar hPa Torr 3 10 12 10 11 10 10 10 9 10 8 10 6 10 5 10 4 10 3 10 2 10 2 10 1 1 101 102 103 COR mbar l s STDBY LEAK RATE EVAC TEST Pa m3 s Torr l s 10 7 How to read the He signal analog scale reject point is visualized by a blinking led if the leak value exceeds the reject point the leds will turned red the blinking led will turn orange if the leak value remains under the reject point th...

Страница 8: ...um signal zero scale The He signal zero scale displays 2 leds signal centered around the zero value Example 2 leds flash 1 10 7 1 10 8 1 1 10 7 9 10 8 2 10 7 Purpose the zero function offers the operator the possibility to detect small leaks that are smaller than the helium background Activation of zero function connect the part or installation to be tested Operator could find an example in the Op...

Страница 9: ...t valve off indicates that the venting valve is not activated closed at the end of cycle The setting by default is off valve closed F1 F3 F2 F4 READY FOR CYCLE INLET VENT off F3 F3 opening closing F3 F3 Opening closing air inlet valve user level 2 3 or 4 To open close air inlet valve with user level 1 C 500 Air inlet vent ...

Страница 10: ...uest it can be started by the operator whenever needed the unit has to be off cycle The result of the autocalibration process is displayed External The external autocalibration allows direct readout in cases of operation with an auxiliary pumping system F1 F3 F2 F4 READY FOR CYCLE INLET VENT off F1 F3 F2 F4 READY FOR CYCLE INLET VENT off F1 F3 F2 F4 AUTOCAL IN PROGRESS ELECTR ZERO ADJUST 80 To per...

Страница 11: ...t display time of the leak value C 550 To active deactive this function and adjust roughing and measure times C 530 To active deactive this function C 510 To active deactive this function C 560 Assistance to the test Memorization of the latest He signal measured after depressing the CYCLE key at the end of the cycle Device that prevents the unit from getting polluted with Helium Display a greater ...

Отзывы: