31
The key ‘Mode’ under this page is to switch the type of distance between
HD, VD and SD. The default mode is HD. When finishing entering, press the soft
key ‘Enter’ to enter ‘stake-out by distance’ mode as follows.
dhd
is to stake out horizontal distance difference. A positive result indicates
that the measured horizontal distance is greater than the evaluated one. The
lens should be moved to the instrument.
dvd
is to stake out difference between elevation differences. A positive result
indicates that the measured elevation difference is greater than the evaluated one.
The lens should be moved downwards (excavation).
dsd
is to stake out differences between slope distances. A positive result indicates
that the measured slope distance is greater than the evaluated one. The lens should
be shifted to the instrument.
Every time a stake-out is finished, go to the second page with soft key ‘F4’
and press ‘F2’ [Stake] to repeat the process, otherwise press ‘DIST’ to switch back
to Distance Mode.
m/f/i:
switch the units of the displayed distance between meters, feet & inches.
Notes
“
” indicates that the distance measurement is in progress. Now
pressing ‘F1’ or ‘F2’ “ ” or “
” appears on the screen, which indicates that
the distance measurement is in progress and displays the current measuring
mode (S, R, C, T). When quitting distance measurement with ‘ESC’, “
”
disappears. The ‘ ’ indicates distance measurement with prism.
‘
’ indicates distance measurement without prism.