Pb24:  Indication battery check card set for lead bat-

teries. 

GE24:  Indication battery check card set for gel bat-

teries. 

AL01:  Signal indicating an absorption of excessive 

current of the brushes motor, only on machines 

equipped with the overload protection device for the 

brushes pressure adjustment (see under "OPTIONAL 

ACCESSORIES”). 

---- (blinking): signal indicating the discharged bat-

teries and intervention of the brushes stop device. 

 

 

 

THE SUCTION MOTOR DOES NOT WORK 

1.  Verify that the switch (3) is on. 

2.  Verify that the key switch (see under "OPTIONAL 

ACCESSORIES”) is in the correct position (clockwise). 

If the problem persists, please contact the authorized 

technical assistance. 

 

 

 

THE BRUSHES MOTOR DOES NOT WORK 

1.  Verify that the key switch (see under "OPTIONAL 

ACCESSORIES”) is in the correct position (clockwise). 

2.  Check the charge level of the batteries. 

3.  Check that the battery connector (1) is correctly 

plugged in. 

4.  Verify that the switch (5) is on. 

5.  Activate the levers forward movement. 

6.  On machines equipped with brushes motor over-

load protection device (see under "OPTIONAL ACCES-

SORIES”), check that on the display (1) does not ap-

pear the alarm “AL01” (brushes motor overload 

alarm). 

If the problem persists, please contact the authorized 

technical assistance. 

 

 

 

 

 

  ATTENTION: 

Never leave the batteries discharged for a long time. 

 

THE MOTORS DO NOT FUNCTION 

If the machine is supplied with the incorporated bat-

tery recharger (optional), check: 

1.  if the recharging of the batteries is being carried 

out. In this case the machine is not connected. 

2.  that the switches are on. 

3.  that the switch with key  (see under "OPTIONAL 

ACCESSORIES”) is in the correct position. 

If the problem persists, please contact the authorized 

technical assistance. 

 

INSUFFICIENT WATER ON THE BRUSHES 

1.  Check that the solution valve lever (8) is open. 

2.  Check the level of the liquid in the solution tank. 

3.  Check that solution filter (1) is clean. 

4.  The machine is equipped with solenoid valve, 

therefore  act upon the levers forward movement (7). 

If the problem persists, please contact the authorized 

technical assistance. 

 

 

 

THE MACHINE DOES NOT CLEAN PROPERLY 

1.  The brushes do not have the suitable bristle  di-

mension: use only original brushes. For advice, con-

tact the authorized technical assistance. 

2.  The brushes have got worn bristles. Check the 

brushes wear condition and eventually replace them. 

To replace the brushes, see instructions at paragraph 

“BRUSHES DISASSEMBLY” and “BRUSHES ASSEMBLY”. 

3.  The solution detergent is insufficient: open more 

the solution valve. 

4.  Check that the liquid detergent is in the recom-

mended percentage. 

Contact the authorized technical assistance for ad-

vice. 

 

THE SQUEEGEE DOES NOT DRY PERFECTLY 

1.  Check that the squeegee rubbers are clean. 

2.  Check the height and inclination of the squeegee 

(see under “SQUEEGEE” in “BEFORE USE”). 

3.  Check that the suction hose is correctly inserted 

in the proper seat on the recovery tank. 

4.  Clean the suction filter. 

5.  Replace the rubbers if worn out. 

6.  Check that the suction motor switch is on. 

7.  Check that the recovery tank is empty. 

 

EXCESSIVE FOAM PRODUCTION 

Check that low foam detergent has been used. Even-

tually add small quantities of anti foam liquid into 

the recovery tank. 

Please be aware that a bigger quantity of foam is 

produced when the floor is not very dirty. In this ca-

se please dilute detergent solution. 

 

Содержание ruby 45c

Страница 1: ...ruby 45c 10 2015 Use and maintenance Attention Please read the instructions before use...

Страница 2: ......

Страница 3: ...arting of the machine 9 Adjustment of the brushes pressure 9 Brushes motor overload protection device optional 9 Overflow device 9 Emptying detergent solution 10 Emptying device detergent solution opt...

Страница 4: ...EDAL BRUSHES BASE GROUP LIFTING LEGEND MACHINE 1 CASTOR WHEELS 2 WHEELS 3 BRUSHES BASE GROUP 4 SOLENOID VALVE 5 SOLUTION TANK 6 SCREW CAP FOR INLET DETERGENT SOLUTION 7 RECOVERY TANK 8 PLUG EXHAUST HO...

Страница 5: ...mm 2x95 Brushes rpm rpm 950 Pressure on the brushes kg 30 max Brushes motor W 500 Type of drive semi aut Maximum gradient 2 Suction motor W 570 Suction vacuum mbar 120 Solution tank l 40 Recovery tank...

Страница 6: ...able signs If the machine does not work properly check by conducting simple maintenance procedures Other wise ask for technical advice to an authorized assis tance centre Where parts are required ask...

Страница 7: ...for the maintenance and daily recharge of the bat teries All installation and maintenance operations must be executed by specialized staff using suitable protection accessories BATTERY RECHARGER Be su...

Страница 8: ...e working hours and after a few seconds the working minutes are shown SQUEEGEE ASSEMBLY With the squeegee support lowered slide the two stud bolts 1 placed on the upper part of the squee gee inside th...

Страница 9: ...equipped with solenoid valve The flow of detergent solution will be activated automatically once the solution valve has been opened through the lever 8 acting upon the levers forward move ment 7 Relea...

Страница 10: ...1 Hold the exhaust hose placed in the front part of the machine 2 Take off the exhaust plug acting upon its lever and empty the recovery tank into appropriate con tainers see under OVERFLOW DEVICE 3 T...

Страница 11: ...reverse the opera tions above mentioned CLEANING OF SOLUTION TANK AND FILTER 1 Bring the machine to an appropriate place for tanks draining 2 Unscrew the solution tank cap 1 3 Unscrew the exhaust plu...

Страница 12: ...the switch with key see under OPTIONAL ACCESSORIES is in the correct position If the problem persists please contact the authorized technical assistance INSUFFICIENT WATER ON THE BRUSHES 1 Check that...

Страница 13: ...lene Good wear resistance Maintains characteristics with hot water up to 60 C It is not hygroscopic NYLON Excellent wear resistance even with hot water over 60 C It is hygroscopic It looses its physic...

Страница 14: ...GB GB 14...

Отзывы: