SCAN (SCAN)
SCAN (SCAN)
It allows you to monitor the frequencies you want without the necessity
of operating manually. After being familiar with various scan modes, you
will increase your efficiency from flexibility of monitoring.
The transceiver provides with the following scan modes :
•
VFO frequency scan : All frequencies in the entire band.
•
Memory channel scan : Channels stored in the internal memory
channel.
SCAN METHOD
SCAN METHOD
Before using scan, it’s necessary to decide under what condition you
want your transceiver to continue scanning after detecting and stopping
for a signal. You can select one of the following modes :
•
Time-Operated Mode (TO)
The transceiver stops scanning when detecting a signal,
remaining for about 5 seconds, and then continues to scan even if
the signal is still present.
•
Carrier-Operated Mode (CO)
The transceiver stops scanning when detecting a signal,
remaining on the same channel until the signal disappears. There
is a 2 seconds delay between signal disappearance and scan
resumption to allow time for any responding stations to begin
transmitting.
Note : Press any key other than LAMP, / will make the transceiver stop
scanning.
SELECTING SCAN METHOD
SELECTING SCAN METHOD
1.Press + to enter into Scan method selection.
2.Use / keys to select :
•
:
Carrier - Operated Mode.
•
:
Time - Operated Mode.
VFO SCAN
VFO SCAN
VFO scan allows you to scan all frequencies from the lowest to the
highest frequency in the entire band.
1.Press key to begin scanning under VFO mode.
•
The scan will begin from the present frequency displayed on the
LCD.
•
To control scan direction, press key to scan forward, or key
to scan backward.
2.To cancel VFO scan, press any key other than LAMP, / .
MEMORY CHANNEL SCAN
MEMORY CHANNEL SCAN
Memory channel scan allows all stored memory channles to be
scanned.
1.Press key to enter into Memory channel scan.
2.Press key to begin scanning.
•
Scan starts with the channel last recalled.
•
To control scan direction, press key to scan forward, or key
to scan backward.
3.To cancel Memory channel scan, press any key other than LAMP,
/ .
Note:
1.You have to store at least 2 memory channels without being locked so that you
can proceed with memory channel scan.
2.The squelch function must be closed for scan to function.
3.You can proceed with memory channel scan under channel display mode.