![ADI AF-16 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/adi/af-16/af-16_user-manual_2851264011.webp)
ADJUST SQUELCH (SQL)
ADJUST SQUELCH (SQL)
The purpose of the Squelch is to mute the speaker when no signals
are present (squelch circuit closed). With the squelch level correctly
set, you will hear sound only when actually receiving a signal (squelch
circuit open).
1.Press + keys.
•
The present squelch level appears.
2.Use / to select the squelch level within the range of 0-9
(default value :2).
•
Select a level at which the background noise is just eliminated
when no signal is present.
•
The larger the level number you select, the stronger the signal
you need to receive, and the smaller the receiving range.
3.Press any key other than [LAMP], ,and to complete the
setting.
BATTERY SAVER (SAVE)
BATTERY SAVER (SAVE)
The battery saver function decreases the power consumption by
reducing circuit when a signal is not being received, so as to extend
the battery life. When squelch level is 0 or Battery Saver key is
pressed again, battery saver will be disabled. You can switch this
function ON or OFF by pressing + . When it is ON,
will appear.
F
1
SQL
F
AUTOMATIC POWER OFF (APO)
AUTOMATIC POWER OFF (APO)
Automatic Power Off is a background function that monitors whether
any keys have been pressed, or whether any knobs have been turned.
If no operation within one hour, APO will automatically turn off the
power. However, 1 minute before the power turns off, will flash and a
warning beep sounds.
1.Press + .
•
Turn on/off APO.
2.Use / to select the setting time within the range of 0-15
(Default value : 00).
•
If the squelch opens or any settings are changed during the setting
time period while APO is ON, the timer resets. When the squelch
closes or you stop changing the settings, the timer begins counting
again from 0.
KEYPAD BEEPER (BEEP)
KEYPAD BEEPER (BEEP)
The transceiver beeps each time if you press a key on the keypad. You
can use the following to turn on or off the beeper (Default : on).
1.Press + to enter into the beeper setting.
2.Use / to select on (bP on)/off(bP off).
KEYPAD LOCK (LOCK)
KEYPAD LOCK (LOCK)
Press and hold key for 3 seconds to lock keys. There are 4 lock
modes for you to control the lock way for your transceiver .
Press + keys to enter into setting, there are 4 lock ways lock
ways available.
1.Loc S : Keypad and / keys re locked.
2.Loc P : Only lock the [PTT] switch to prevent the transceiver from
being wrongly transmitted by yourself or others.
3.Loc n : Only lock the keypad to prevent the setting from being
changed incidentally.
4.Loc A : Except
,
[LAMP] keys, the remaining keys are all
locked.
F
F
F
F
F
LOCK
LOCK
15
FUNCTION SETTING AND DESCRIPTION
FUNCTION SETTING AND DESCRIPTION
Содержание AF-16