DTU4x0 GPRS/NB-IoT Data Loggers
User Guide. r. 2.01 | 2022-05-17
Tel.: +420 234 076 670
6
e-mail: [email protected]
Technical Specifications
DTU410
DTU410-C
DTU420
DTU420-C
POWER SUPPLY
Main power supply source
7-30VDC
100-240VAC
50Hz/60Hz
7-30VDC
100-240VAC
50Hz/60Hz
Max. power consumption
5W
1
5W
1W
1
Connector
2-pin screw terminal block, pitch – see
DTU4x0 power supply terminal block contacts
Backup power supply
source
Li-SOCL2 D-type ER34615M battery, 3.6V 13 000 mAh - for base models.
For optional modifications, see
Current consumption in a
sleep mode (when
powered by battery)
10 µA (at 2 Hz polling rate), 40 µA (at 20 Hz polling rate),
150 µA (at 100 Hz polling rate)
2
Current consumption in
data transfer mode (when
powered by battery)
150 mA
36 mA
Battery life
Up to 4 years
Up to 8 years
CELLULAR NETWORK PARAMETERS
Module frequency range
GSM/GPRS 850/900/1800/1900
NB-IoT B1/B2/B3/B5/B8/B12/B13/B17/B18
B19/B20/B25/B26/B28/B66/B70/B71
Max. power output
33dBm (850/900 MHz)
30dBm (1800/1900 MHz)
23dBm
Data transmission
technology
GPRS class: configured 8/10/auto (up to 12)
NB-IoT Cat NB2
Data transmission rate
up to 85.6 kbps (DL/UL)
100 kbps (DL) / 150 kbps (UL)
Protocol Stacks
IPv4 TCP
IO PARAMETERS
GPIOs (
P1-P4
)
x4
: operating modes - pulse counter; high-frequency (HF) pulse counter (up to 5kHz);
two-state signal input; leakage sensor; opening sensor, engine hours counter;
1-Wire; current loop 4-20mA sensor; temperature sensor.
Counting inputs (
P5-P10
)
x6
: operating modes – pulse counter, HF pulse counter (up to 5kHz);
two-state signal input; leakage sensor, temperature sensor, engine hours counter.
Additional Input (
P11
)
x1
: type - pulse counter, leakage sensor (
S+
,
S-
contacts)
Pulse input polling
frequency
3
2Hz:
pulse duration – more than 500ms, max. pulse frequency at the input – 1Hz;
20Hz
(
default
): pulse duration – more than 50ms, max. pulse frequency at the input – 10Hz;
100Hz
: pulse duration – more than 10ms, max. pulse frequency at the input – 50Hz
Input conditions
closed, open, short circuit, break
Connector type
screw terminal block, pitch - 5.0 mm
Unit of measured value
pulse, ohms, mA, °C, ppm
Pulse counting range
0 - 2
32
Relative error of pulse-
counting (per 10000 pulses)
±0,01%
1
Without taking into account the load at the 12V and 7.5V power outputs.
2
If all inputs are configured as counting and the 12V and 7.5V power outputs are turned off.
3
When operating at a temperature not higher than 0°C, with a stable communication signal, in the connection mode 3
times
a
month. Battery service life depends on a number of factors, including operating temperature, type of connection and frequency
of connections.
ATTENTION
! Increasing the polling frequency results in a shorter battery life.