background image

DTU4x0 GPRS/NB-IoT Data Loggers

 

User Guide. r. 2.01 | 2022-05-17

 
 

 

Tel.:  +420 234 076 670

 

6

 

    e-mail: [email protected]

 

Technical Specifications

 

 

DTU410

 

DTU410-C

 

DTU420

 

DTU420-C

 

POWER SUPPLY

 

Main power supply source

 

7-30VDC

 

100-240VAC 

50Hz/60Hz

 

7-30VDC

 

100-240VAC

 

50Hz/60Hz

 

Max. power consumption

 

5W

1

 

5W

1

 

1W

1

 

1W

1

 

Connector

 

2-pin screw terminal block, pitch – see 

DTU4x0 power supply terminal block contacts

 

Backup power supply 
source

 

Li-SOCL2 D-type ER34615M battery, 3.6V 13 000 mAh - for base models.

 

For optional modifications, see 

available

 

options

 

Current consumption in a 

sleep mode (when 

powered by battery)

 

10 µA (at 2 Hz polling rate), 40 µA (at 20 Hz polling rate),

 

150 µA (at 100 Hz polling rate)

2

 

Current consumption in 
data transfer mode (when 
powered by battery)

 

150 mA

2

 

36 mA

2

 

Battery life

 

Up to 4 years

3

 

Up to 8 years

3

 

CELLULAR NETWORK PARAMETERS

 

Module frequency range

 

GSM/GPRS 850/900/1800/1900 

 

NB-IoT B1/B2/B3/B5/B8/B12/B13/B17/B18 

B19/B20/B25/B26/B28/B66/B70/B71

 

Max. power output

 

33dBm (850/900 MHz)

 

30dBm (1800/1900 MHz)

 

23dBm

 

Data transmission 
technology

 

GPRS class: configured 8/10/auto (up to 12)

 

NB-IoT Cat NB2

 

Data transmission rate 

 

up to 85.6 kbps (DL/UL)

 

100 kbps (DL) / 150 kbps (UL) 

 

Protocol Stacks

 

IPv4 TCP

 

IO PARAMETERS

 

GPIOs (

P1-P4

)

 

x4

: operating modes - pulse counter; high-frequency (HF) pulse counter (up to 5kHz); 

 

two-state signal input; leakage sensor; opening sensor, engine hours counter; 

 

1-Wire; current loop 4-20mA sensor; temperature sensor.  

 

Counting inputs (

P5-P10

)

 

x6

: operating modes – pulse counter, HF pulse counter (up to 5kHz); 

 

two-state signal input; leakage sensor, temperature sensor, engine hours counter.

 

Additional Input (

P11

)

 

x1

: type - pulse counter, leakage sensor (

S+

S-

 contacts)

 

Pulse input polling 

frequency

3

 

2Hz:

 pulse duration – more than 500ms, max. pulse frequency at the input – 1Hz;

 

20Hz

 

(

default

): pulse duration – more than 50ms, max. pulse frequency at the input – 10Hz;

 

100Hz

: pulse duration – more than 10ms, max. pulse frequency at the input – 50Hz

 

Input conditions

 

closed, open, short circuit, break

 

Connector type

 

screw terminal block, pitch - 5.0 mm

 

Unit of measured value

 

pulse, ohms, mA, °C, ppm

 

Pulse counting range

 

0 - 2

32

 

Relative error of pulse-

counting (per 10000 pulses)

 

±0,01%

 

 

1

 

Without taking into account the load at the 12V and 7.5V power outputs.

 

2

 

If all inputs are configured as counting and the 12V and 7.5V power outputs are turned off.

 

3

 When operating at a temperature not higher than 0°C, with a stable communication signal, in the connection mode 3

 

times 

a

 

month. Battery service life depends on a number of factors, including operating temperature, type of connection and frequency 

of connections. 

ATTENTION

! Increasing the polling frequency results in a shorter battery life.

 

Содержание DTU4 0 Series

Страница 1: ...GPRS NB IoT Data Loggers DTU4x0 User Guide Revision 2 01 May 2022...

Страница 2: ...acies Safety Symbols Information The following safety symbols are used in the document Familiarize yourself with the symbols before installing and operating the device WARNING Denotes a hazard It call...

Страница 3: ...switched ON Make sure to power OFF the external power supply before opening the case cover For safety reasons after disconnecting the external power supply wait for 1 second before opening the case c...

Страница 4: ...ption 5 Technical Specifications 6 Appearance 8 DTU4x0 Interfaces and Wiring Diagrams 10 DTU4x0 Operating Modes 13 LED Indication 14 Collection and storage of information 15 Algorithm of data logger c...

Страница 5: ...mote 24 7 access to data via a convenient web interface Power supply both external and autonomous from a backup replaceable 3 6 V battery to provide data logger operation up to 4 years and above The b...

Страница 6: ...rating modes pulse counter high frequency HF pulse counter up to 5kHz two state signal input leakage sensor opening sensor engine hours counter 1 Wire current loop 4 20mA sensor temperature sensor Cou...

Страница 7: ...x mini USB B Antenna Connector DTU4x0 internal flexible antenna 2 5 2dBi on the u Fl connector SMA f connector DTU4x0 F u Fl connector SMA f connector DEFAULT SETTINGS Data slice saving once per hour...

Страница 8: ...r Guide r 2 01 2022 05 17 Tel 420 234 076 670 8 e mail info adgt cz Appearance DTU4x0 is a single board microcontroller device in a sealed plastic IP65 case DTU410 DTU420 7 30 VDC power supply DTU410...

Страница 9: ...ut8 Lower Terminal blocks Terminal block J2 3 pin 7 GND Ground GPIO P1 Universal GPIO 1 P2 Universal GPIO 2 Terminal block J1 2 pin 7 P3 Universal GPIO 3 P4 Universal GPIO 4 Terminal block J14 2 pin 7...

Страница 10: ...nter High frequency pulse counter Signal two state input Leakage sensor ADGT temperature sensor Engine hours sensor DTU case opening sensor 1 Wire Current loop 4 20mA sensor types of devices supported...

Страница 11: ...types of inputs are available for connecting sensors Signal the type of input used when connecting to DTU two state sensors measuring resistance temperature sensors leakage magnetic impact etc Thresh...

Страница 12: ...nt loop sensor the type of input used when connecting 4 20 mA current sensors to data logger When this input is selected a 100 Ohm load resistor is switched on at the input and the 12V and 7 5V power...

Страница 13: ...erver with the subsequent data transfer The default server is https iot24 eu cloud software with access via the web interface Data logger establishes a connection with the server in the following case...

Страница 14: ...re presented in table below Function Condition Description External power connection ST1 is ON External power supply connected ST1 is OFF External power is not connected Switching the device to con fi...

Страница 15: ...ected to a PC SIM operation modes Auto default in this mode DTU registers on SIM card on which the connection was successfully established earlier when first turned on on SIM1 If registration fails da...

Страница 16: ...and its designation should be visually accessible and easily identified by the function performed All installation works should be performed with external and battery power supply disabled Power suppl...

Страница 17: ...ules for crimping stranded wires of meters crimper Installation and Connection 1 Remove data logger case cover by unscrewing four screws on the cover NOTE Inside you will see a battery power jumper in...

Страница 18: ...the two holes in the middle of the board We recommend slightly bending the tip of the cable tie to make it easier to pull it out Place the battery on the top of SIM slots Firmly fix the battery with...

Страница 19: ...able The hole of cable gland A is closed with a rubber plug To insert cables into the plug you need to make an incision of the desired size The holes of cable glands B and C are closed with blind plug...

Страница 20: ...connector Data logger will automatically detect the levels and thresholds at the inputs afterwards will connect to https iot24 eu server and transmit the data to the server To track the beginning and...

Страница 21: ...hed indicators ST2 ST3 will start flashing Remember or write down readings at the time of pressing the button You will need this data to enter initial data later in the web interface 9 Seal the wires...

Страница 22: ...e data logger when connected locally to a PC via USB using the DTU Configuration Tool software You can download the program on our website https adgt cz Firmware Update You can update data logger firm...

Отзывы: