ETHERNET:

 

 
EtherNet/IP connection and the updating of the converter must be made using Connector9 and/or Connector10 of the HD67E26-A1 with at 
least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative 
to connections in cat.5 up to 100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the 
device to a PC/PLC/other is recommended the use of a cross cable. 

 

 

Содержание HD67E26-A1

Страница 1: ...b com Product HD67E05 BACnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Maste...

Страница 2: ...RANTIES AND TECHNICAL SUPPORT 26 RETURN POLICY 26 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Re...

Страница 3: ...The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and oper...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave EtherNet IP Master Document code MN67E26_ENG Revision 1 000 Page 4 of 26 EXAMPLE OF CONNECTION...

Страница 5: ...ustrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave EtherNet IP Master Document code MN67E26_ENG Revision 1 000 Page 5 of 26 CONNECTION SCHEME Figure 1 Connection scheme for HD67E26...

Страница 6: ...formation between EtherCAT bus and EtherNet IP bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Com...

Страница 7: ...MN67E26_ENG Revision 1 000 Page 7 of 26 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumpt...

Страница 8: ...ng on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is u...

Страница 9: ...therNet IP comm green It blinks when EtherNet IP communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 Error state green ON An error in the communication bus...

Страница 10: ...T the standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them wh...

Страница 11: ...er must be made using Connector9 and or Connector10 of the HD67E26 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norm...

Страница 12: ...that runs with Windows called SW67E26 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software prese...

Страница 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave EtherNet IP Master Converter in order to configure another device in th...

Страница 14: ...ange the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possi...

Страница 15: ...Slave EtherNet IP Master Document code MN67E26_ENG Revision 1 000 Page 15 of 26 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation ins...

Страница 16: ...nverter is defined In the field Slave Name the name of the converter is defined In the field Node Address the ID of the converter is defined The means of the fields for EtherNet IP Master are In the f...

Страница 17: ...y the EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT vari...

Страница 18: ...variable is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherC...

Страница 19: ...side is defined In the field Start Output the starting Output byte of the EtherNet IP Master to write from EtherCAT side is defined In the field Num Output the number of consecutive Output byte to wr...

Страница 20: ...Slave EtherNet IP Master Document code MN67E26_ENG Revision 1 000 Page 20 of 26 ETHERCAT ESI FILE By pressing the EtherCAT ESI File button it is possible to save the ESI file for the EtherCAT side of...

Страница 21: ...Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put D...

Страница 22: ...the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to prog...

Страница 23: ...Electronic Devices ADFweb com S r l User Manual EtherCAT Slave EtherNet IP Master Document code MN67E26_ENG Revision 1 000 Page 23 of 26 MECHANICAL DIMENSIONS Figure 8 Mechanical dimensions scheme for...

Страница 24: ...bination of the following HD67E26 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E26 EtherCAT Slave EtherNet IP Master Converter Order C...

Страница 25: ...llection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Страница 26: ...ease do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the produ...

Отзывы: