background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

EtherCAT Slave / PROFINET Master

 

 

Document code: MN67E22_ENG     Revision 1.000   Page 2 of 28

 

 

 

INDEX:

 

 

 

Page 

INDEX 

UPDATED DOCUMENTATION 

REVISION LIST 

WARNING 

TRADEMARKS 

SECURITY ALERT 

EXAMPLE OF CONNECTION 

CONNECTION SCHEME 

CHARACTERISTICS 

CONFIGURATION 

POWER SUPPLY 

FUNCTION MODES 

LEDS 

ETHERCAT 

10 

ETHERNET 

11 

USE OF COMPOSITOR SW67E22 

12 

NEW CONFIGURATION / OPEN CONFIGURATION 

13 

SOFTWARE OPTIONS 

14 

SET COMMUNICATION 

16 

ETHERCAT SET ACCESS 

17 

PROFINET ACCESS 

19 

ETHERCAT ESI FILE 

22 

UPDATE DEVICE 

23 

MECHANICAL DIMENSIONS 

25 

ORDERING INFORMATIONS 

26 

ACCESSORIES 

26 

DISCLAIMER 

27 

OTHER REGULATIONS AND STANDARDS 

27 

WARRANTIES AND TECHNICAL SUPPORT 

28 

RETURN POLICY 

28 

UPDATED DOCUMENTATION: 
 

Dear  customer,  we  thank  you  for  your  attention  and  we  remind  you  that 
you need to check that the following document is: 

 

Updated 

 

Related to the product you own

 

 
To  obtain  the  most  recently  updated document,  note  the  “document  code” 
that appears at the top right-hand corner of each page of this document. 
 
With  this  “Document  Code”  go  to  web  page  www.adfweb.com/download/ 
and  search  for  the  corresponding  code  on  the  page.  Click  on  the  proper 
“Document Code” and download the updates. 

 

 

REVISION LIST: 

 

 

 

WARNING: 
 

ADFweb.com reserves the right to change information in this manual about 
our product without warning. 
ADFweb.com is not responsible for any error this manual may contain.

 

 

 

TRADEMARKS: 
 

All  trademarks  mentioned  in  this  document  belong  to  their  respective 
owners. 

Revision 

Date 

Author 

Chapter 

Description 

1.000 

18/09/2020 

Ff 

All 

First Release 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание HD67E22-A1

Страница 1: ...Product HD67E05 BACnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Master www...

Страница 2: ...TIES AND TECHNICAL SUPPORT 28 RETURN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Relat...

Страница 3: ...he device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and opera...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave PROFINET Master Document code MN67E22_ENG Revision 1 000 Page 4 of 28 EXAMPLE OF CONNECTION...

Страница 5: ...dustrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave PROFINET Master Document code MN67E22_ENG Revision 1 000 Page 5 of 28 CONNECTION SCHEME Figure 1 Connection scheme for HD67E22 A...

Страница 6: ...formation between EtherCAT bus and PROFINET bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compos...

Страница 7: ...MN67E22_ENG Revision 1 000 Page 7 of 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumpti...

Страница 8: ...g on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is us...

Страница 9: ...PROFINET comm green It blinks when PROFINET communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 Error state green ON An error in the communication busses o...

Страница 10: ...the standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them whil...

Страница 11: ...must be made using Connector9 and or Connector10 of the HD67E22 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms r...

Страница 12: ...hat runs with Windows called SW67E22 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Страница 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave PROFINET Master Converter in order to configure another device in the s...

Страница 14: ...ge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possibl...

Страница 15: ...AT Slave PROFINET Master Document code MN67E22_ENG Revision 1 000 Page 15 of 28 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insi...

Страница 16: ...PROFINET side of the converter is defined In the fields SubNet Mask the SubNet Mask for PROFINET side of the converter is defined In the fields Gateway the default gateway of the net is defined This...

Страница 17: ...ROFINET ACCESS By Pressing the PROFINET Access button from the main window for SW67E22 Fig 2 the window Definition of PROFINET Devices Present in Network appears Fig 4 This section is used to define t...

Страница 18: ...ave is defined If the field Automatic new session when StationProblemIndicator is active is checked the converter will restart the PROFINET communication when the error indicator in the slave is prese...

Страница 19: ...in table it is possible to import the Modules of the PROFINET device in use In the properties below it is possible to set the parameters of the slave These options depends on the slave in use refer to...

Страница 20: ...the EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT varia...

Страница 21: ...riable is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherCAT...

Страница 22: ...T Slave PROFINET Master Document code MN67E22_ENG Revision 1 000 Page 22 of 28 ETHERCAT ESI FILE By pressing the EtherCAT ESI File button it is possible to save the ESI file for the EtherCAT side of t...

Страница 23: ...thernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip...

Страница 24: ...the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to progr...

Страница 25: ...Electronic Devices ADFweb com S r l User Manual EtherCAT Slave PROFINET Master Document code MN67E22_ENG Revision 1 000 Page 25 of 28 MECHANICAL DIMENSIONS Figure 9 Mechanical dimensions scheme for H...

Страница 26: ...ombination of the following HD67E22 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E22 EtherCAT Slave PROFINET Master Converter Order Co...

Страница 27: ...lection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Страница 28: ...se do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Отзывы: