Industrial
Electronic Devices
ADFweb.com S.r.l.
User Manual
LoRaWAN / CANopen
Document code: MN67D20_ENG Revision 1.000 Page 19 of 33
CAN
OPEN
:
This section is used to define the general parameters of LoRaWAN. The means of the
fields are:
In the field “
ID Device
” the ID of the CANopen side is defined;
In the field “
Baudrate
” the data rate of the CANopen line is defined;
In the field “
Set Operational State at Start-Up
” the state of the CANopen is
defined. I.e. If it is checked the board starts in Operational State, else it starts
in Pre-Operational;
In the field “
Network Start at Start-Up
” the state of the CANopen network is
defined. I.e. If it is checked the board sends a command to set the Operational
State of all the devices present in the network, after the time defined in the
“Delay” field;
In the field “
Delay (seconds)
” the delay before sending the “Start” command
for the CANopen is defined;
In the field “
SDO Client TimeOut (1/10 ms)
” the maximum time that the
device attends for the answer from the Slave interrogated is defined;
E
THERNET
:
This section is used to define the general parameters of LoRaWAN. The means of the
fields are:
In the fields “
IP Address
” the IP address for Ethernet side of the converter is
defined;
In the fields “
SubNet
Mask
” the SubNet Mask for Ethernet side of the converter
is defined;
In the fields “
Gateway
” the default gateway of the net is defined. This feature
can be enabled or disabled pressing the Check Box field. This feature is used for
going out of the net;
In the fields “
DNS
” the IP address of the DNS server is defined
Figure 3c: “Set Communication
CANopen”
window
Figure 3d: “Set Communication
Ethernet” window