background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

IEC61850 Client / Modbus TCP Slave 

 

Document code: MN67766_ENG     Revision 1.000    Page 16 of 32

 

 

 

NEW CONFIGURATION / OPEN CONFIGURATION:

 

 
The  “

New Configuration

” button creates the folder which contains the entire device’s configuration. 

 

 

 

 

 

 

 

 

 

 
 
A device’s configuration can also be imported or exported: 

 

To  clone  the  configurations  of  a  programmable  “IEC61850  Client  /  Modbus  Slave  - 

Converter” in order to configure another device in the same manner, it is necessary to 
maintain the folder and all its contents; 

 

To clone a project in order to obtain a different version of the project, it is sufficient to 

duplicate  the  project  folder  with  another  name  and  open  the  new  folder  with  the 
button “

Open Configuration

”. 

Содержание HD67765-2-A1

Страница 1: ...web com Product HD67766 Modbus TCP Slave www adfweb com Product HD67767 BACnet Slave www adfweb com Product HD67768 CAN www adfweb com Product HD67769 CANopen www adfweb com Product HD67770 DeviceNet...

Страница 2: ...31 WARRANTIES AND TECHNICAL SUPPORT 32 RETURN POLICY 32 Pagina 2 di 32 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following d...

Страница 3: ...erlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation...

Страница 4: ...ronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC61850 Client Modbus TCP Slave Document code MN67766_ENG Revision 1 000 Page 4 of 32 EXAMPL...

Страница 5: ...com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC61850 Client Modbus TCP Slave Document code MN67766_ENG Revision 1 000 Page 5 of 32 CONNECTION SCHEME Figure 1...

Страница 6: ...es ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC61850 Client Modbus TCP Slave Document code MN67766_ENG Revision 1 000 Page 6 of 32 Figure 1b Connect...

Страница 7: ...es ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC61850 Client Modbus TCP Slave Document code MN67766_ENG Revision 1 000 Page 7 of 32 Figure 1c Connect...

Страница 8: ...e isolation between RS232 RS485 RS422 Power Supply RS232 RS485 RS422 Ethernet Ethernet Power Supply Two directional information between Modbus and IEC61850 Mountable on 35mm Rail DIN Wide power supply...

Страница 9: ...Modbus TCP Slave Document code MN67766_ENG Revision 1 000 Page 9 of 32 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin V...

Страница 10: ...The device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second...

Страница 11: ...OFF Device not powered 2 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 Modbus comm green Flashing Modbus request OFF No Modbus request Bl...

Страница 12: ...Ethernet connection must be made using Connector3 or Connector4 of HD67765 x A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to th...

Страница 13: ...d 3 are crossed It is recommended that the RS232 cable not exceed 15 meters RS485 For terminate the RS485 line with a 120 resistor it is necessary to put ON dip 1 like in figure The maximum length of...

Страница 14: ...1 31 User Manual IEC61850 Client Modbus TCP Slave Document code MN67766_ENG Revision 1 000 Page 14 of 32 RS422 For terminate the RS485 line with a 120 resistor it is necessary to put ON dip 1 for T li...

Страница 15: ...rter use the available software that runs with Windows called SW67765 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the las...

Страница 16: ...contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable IEC61850 Client Modbus Slave Converter in order to c...

Страница 17: ...n there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the sectio...

Страница 18: ...438 30 91 31 User Manual IEC61850 Client Modbus TCP Slave Document code MN67766_ENG Revision 1 000 Page 18 of 32 In the section Software Settings it is possible to enable disable some keyboard s comma...

Страница 19: ...heck Box field This feature is used for going out of the net In the field VLAN the identifier for the VLAN is defined In the field Application ID the Goose identification string is defined The means o...

Страница 20: ...ave Document code MN67766_ENG Revision 1 000 Page 20 of 32 Figure 4 IEC61850 Client Set Access window IEC61850 ACCESS By Pressing the IEC61850 Access button from the main window for SW67765 Fig 2 the...

Страница 21: ...onal structure By clicking on ADD IEC Device it is possible to add a new IEC61850 Server A SCL file has to be selected the allowed extensions are scd ssd sed icd iid or cid The functional structure of...

Страница 22: ...he IEC61850 variable is defined In the field fc the Functional Constraint of the IEC61850 variable is defined In the field Reference the path of the IEC61850 variable is defined In the field IP Addres...

Страница 23: ...he starting byte of the internal memory arrays where saving getting the value is defined In the field Start Bit the starting bit of the byte of the field Position is defined only for BOOLEAN data In t...

Страница 24: ...which the IEC61850 Dataset belongs is defined In the field Reference the path of the IEC61850 Dataset is defined In the field Goose Name the Goose Name of the IEC61850 Dataset is defined if En Goose i...

Страница 25: ...d Reference the path of the IEC61850 variable is defined In the field Position the starting byte of the internal memory arrays where saving getting the value is defined In the field Start Bit the star...

Страница 26: ...Turn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations a...

Страница 27: ...r PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure t...

Страница 28: ...Bytes Position 2 3 of internal array Input Register 2 04 Input Bytes Position 4 5 of internal array Input Register 699 04 Input Bytes Position 1398 1399 of internal array Data in writing Type Address...

Страница 29: ...IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IEC61850 Client Modbus TCP Slave Document code MN67766_ENG Revision 1 000 Page 29 of 32 MECHANICAL DIMENSIONS Figure 10 M...

Страница 30: ...Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Modbus port 2 RS232 4 RS422 5 RS485 Device Family HD67765 IEC 61850 Client Modbus Slave Converter Order Code HD67765 2 A1 IEC 61850 Client Mo...

Страница 31: ...opean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an app...

Страница 32: ...ish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information a...