background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

BACnet Master / PROFIBUS Slave

 

 

Document code: MN67716_ENG     Revision 1.001   Page 15 of 28

 

 

 

SOFTWARE OPTIONS: 

 

By  pressing  the  “

Settings

”  (

)  button    there  is  the  possibility  to  change  the  language  of  the  software  and  check  the  updatings  for  the 

compositor. 
 
In  the  section  “Language”  it  is  possible  to  change  the  language  of  the 
software. 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
In  the  section  “Connection  Options”,  it is  possible  to  check  if  there  are  some 
updatings of the software compositor in ADFweb.com website. 
Checking  the  option  “

Check  Software  Update  at  Start  of  Program

”,  the 

SW67716 check automatically if there are updatings when it is launched.  

Содержание HD67716-IP-A1

Страница 1: ...roducts see also the following link Converter BACnet Master to www adfweb com Product HD67704 DMX www adfweb com Product HD67712 Modbus Slave www adfweb com Product HD67714 Modbus TCP Slave www adfweb...

Страница 2: ...URN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obta...

Страница 3: ...e device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operat...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Master PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 4 of 28 EXAMPLES OF CONNECTION...

Страница 5: ...ustrial Electronic Devices ADFweb com S r l User Manual BACnet Master PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 5 of 28 CONNECTION SCHEME Figure 1a Connection scheme for HD67716 IP...

Страница 6: ...Industrial Electronic Devices ADFweb com S r l User Manual BACnet Master PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 6 of 28 Figure 1b Connection scheme for HD67716 MSTP A1...

Страница 7: ...tween PROFIBUS Power Supply PROFIBUS BACnet BACnet Power Supply Two directional information between PROFIBUS bus and BACnet bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12...

Страница 8: ...001 Page 8 of 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Device Co...

Страница 9: ...st with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the...

Страница 10: ...BUS comm green Blinks quickly when PROFIBUS communication is working Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 Device state green Blinks slowly 1Hz Blinks quickly Boot st...

Страница 11: ...use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable RS485 The BACnet MS TP connection must be made using Connector5 of HD67716 MSTP A1 To terminate...

Страница 12: ...PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 12 of 28 PROFIBUS The PROFIBUS uses a 9 pin D SUB connector The pin assignment is defined like in the right figure Here some codes of cabl...

Страница 13: ...at runs with Windows called SW67716 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Страница 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable BACnet Master PROFIBUS Slave Converter in order to configure another device in the sam...

Страница 15: ...ge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possibl...

Страница 16: ...t Master PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 16 of 28 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insid...

Страница 17: ...S the IP address of BACnet IP side of the converter is defined In the field SUBNET Mask the SubNet Mask of the converter is defined In the field GATEWAY the default gateway of the net is defined This...

Страница 18: ...owable address for master nodes The value shall be less than or equal to 127 The field Max Info Frames specifies the maximum number of information frames the node may send before it must pass the toke...

Страница 19: ...e window Read are the follows In the field IP Address ID the IP address ID of the slave that contains the data to be read is defined In the field Object Type the BACnet object to read is defined In th...

Страница 20: ...n the field Poll Time the frequency of the request is defined In the field Max Error the number of consecutive errors that the Master waits before discard the row from the cycle of requests is defined...

Страница 21: ...Byte the number of bytes to take from PROFIBUS array is defined By checking the field En Dest it is possible to enable the Destination Network D Net Destination Length D Len and Destination Address D...

Страница 22: ...d Start Bit is used for the Binary BACnet objects It is possible to select the bit in the byte from which taking the data By checking the field Swap it is possible to swap the order of data to write t...

Страница 23: ...Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip2 of Dip Switch A in...

Страница 24: ...s for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windo...

Страница 25: ...S r l User Manual BACnet Master PROFIBUS Slave Document code MN67716_ENG Revision 1 001 Page 25 of 28 MECHANICAL DIMENSIONS Figure 7a Mechanical dimensions scheme for HD67716 IP A1 Figure 7b Mechanic...

Страница 26: ...Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting BACnet type IP BACnet IP MSTP BACnet MS TP Device Family HD67716 BACnet Master PROFIBUS Slave Converter Order Code HD67716 IP A...

Страница 27: ...ection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the r...

Страница 28: ...e do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Отзывы: