Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

EtherNet/IP / Modbus TCP Slave

 

 

Document code: MN67663_ENG     Revision 1.000   Page 1 of 24

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

 

User Manual 

Revision 1.000 
English

 

 

EtherNet/IP / Modbus TCP Slave - Converter

  

(Order Code:  HD67663-A1) 

 

For Website information:  

www.adfweb.com?Product=HD67663

  

 

For Price information: 

www.adfweb.com?Price=HD67663-A1

 

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Electrical isolation 

 

Two Ethernet ports (for Modbus TCP / EtherNet/IP) 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

For other EtherNet/IP products see also the following link: 

 

Converter EtherNet/IP to  

www.adfweb.com?Product=HD67077

      

(M-Bus)

 

www.adfweb.com?Product=HD67595

      

(CAN)

 

www.adfweb.com?Product=HD67597

      

(DeviceNet Master) 

www.adfweb.com?Product=HD67598

      

(DeviceNet Slave)

 

www.adfweb.com?Product=HD67599

      

(J1939)

 

www.adfweb.com?Product=HD67589

      

(NMEA 2000)

 

www.adfweb.com?Product=HD67591

       

(Modbus Master RS232)

 

www.adfweb.com?Product=HD67591

       

(Modbus Master RS485)

 

www.adfweb.com?Product=HD67592

      

(Modbus Slave RS232)

 

www.adfweb.com?Product=HD67592

      

(Modbus Slave RS485)

 

 

 

Do you have your customer protocol? Then go to: 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? Do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Содержание HD67663-A1

Страница 1: ...85 F For other EtherNet IP products see also the following link Converter EtherNet IP to www adfweb com Product HD67077 M Bus www adfweb com Product HD67595 CAN www adfweb com Product HD67597 DeviceNe...

Страница 2: ...24 RETURN POLICY 24 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own T...

Страница 3: ...e device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operat...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherNet IP Modbus TCP Slave Document code MN67663_ENG Revision 1 000 Page 4 of 24 EXAMPLE OF CONNECTION...

Страница 5: ...ndustrial Electronic Devices ADFweb com S r l User Manual EtherNet IP Modbus TCP Slave Document code MN67663_ENG Revision 1 000 Page 5 of 24 CONNECTION SCHEME Figure 1 Connection scheme for HD67663 A1...

Страница 6: ...mation between Modbus TCP bus and EtherNet IP bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Comp...

Страница 7: ...N67663_ENG Revision 1 000 Page 7 of 24 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumptio...

Страница 8: ...st with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the...

Страница 9: ...e 1 Modbus TCP comm green Blinks when receive Modbus TCP request from the Master Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 1 Device State green Blinks slowly 1Hz Blinks qui...

Страница 10: ...on must be made using Connector3 and or Connector4 of HD67663 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms rel...

Страница 11: ...that runs with Windows called SW67663 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software presen...

Страница 12: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable EtherNet IP Modbus TCP Slave Converter in order to configure another device in the sam...

Страница 13: ...ge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possibl...

Страница 14: ...gateway that you want to use This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the port used for EtherNet IP communic...

Страница 15: ...ear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device Put Dip2 of Dip Switch...

Страница 16: ...he operations for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are...

Страница 17: ...l Electronic Devices ADFweb com S r l User Manual EtherNet IP Modbus TCP Slave Document code MN67663_ENG Revision 1 000 Page 17 of 24 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for HD...

Страница 18: ...combination of the following HD67663 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67663 EtherNet IP Modbus TCP Slave Converter Order C...

Страница 19: ...ommissioning of the EtherNet IP Converter as described on the following pages was accomplished with the help of the RSLogix 5000 software of Rockwell Automation In case of using a control system from...

Страница 20: ...type The HD67663 A1 can uses up to 496 bytes for input assembly instance 101 and 496 bytes for output assembly instance 100 RSLogix 5000 requires a configuration assembly instance Both modules do not...

Страница 21: ...ial Electronic Devices ADFweb com S r l User Manual EtherNet IP Modbus TCP Slave Document code MN67663_ENG Revision 1 000 Page 21 of 24 4 After the configuration is completed the controller tags are c...

Страница 22: ...bus TCP Slave Document code MN67663_ENG Revision 1 000 Page 22 of 24 5 With RSLinks Classic Lite after have done a network scan RSWho and finding the EtherNet IP device it is possible to load the EDS...

Страница 23: ...ection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the r...

Страница 24: ...e do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Отзывы: