Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

M-Bus / M-Bus Wireless / BACnet Slave

 

 

Document code: MN67086_ENG     Revision 1.100   Page 6 of 43

 

 

 
 

 

 

 

Figure 1b: Connection scheme for HD67086-IP-B2-xxxMHz-xxx

 

 

Содержание HD67086-IP-B2 MHz-0 Series

Страница 1: ...w adfweb com Price HD67086 MSTP B2 xxxMHz 40 www adfweb com Price HD67086 MSTP B2 xxxMHz 80 www adfweb com Price HD67086 MSTP B2 xxxMHz 160 www adfweb com Price HD67086 MSTP B2 xxxMHz 250 Benefits and Main Features Very easy to configure Triple electrical isolation Temperature range 40 C 85 C 40 F 185 F For others M Bus products see also the following link Converter M Bus Wireless to www adfweb co...

Страница 2: ...AL SUPPORT 43 RETURN POLICY 43 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb ...

Страница 3: ... The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are in...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual M Bus M Bus Wireless BACnet Slave Document code MN67086_ENG Revision 1 100 Page 4 of 43 EXAMPLE OF CONNECTION ...

Страница 5: ...l Electronic Devices ADFweb com S r l User Manual M Bus M Bus Wireless BACnet Slave Document code MN67086_ENG Revision 1 100 Page 5 of 43 CONNECTION SCHEME Figure 1a Connection scheme for HD67086 IP B2 xxxMHz 0 ...

Страница 6: ...ndustrial Electronic Devices ADFweb com S r l User Manual M Bus M Bus Wireless BACnet Slave Document code MN67086_ENG Revision 1 100 Page 6 of 43 Figure 1b Connection scheme for HD67086 IP B2 xxxMHz xxx ...

Страница 7: ...ndustrial Electronic Devices ADFweb com S r l User Manual M Bus M Bus Wireless BACnet Slave Document code MN67086_ENG Revision 1 100 Page 7 of 43 Figure 1c Connection scheme for HD67086 MSTP B2 xxxMHz 0 ...

Страница 8: ...dustrial Electronic Devices ADFweb com S r l User Manual M Bus M Bus Wireless BACnet Slave Document code MN67086_ENG Revision 1 100 Page 8 of 43 Figure 1d Connection scheme for HD67086 MSTP B2 xxxMHz xxx ...

Страница 9: ...te and Parity for M Bus on wire changeable with software Available wM Bus frequency 169 MHz or 433 MHz or 868 MHz in relation to the order code Mountable on 35mm Rail DIN Wide power supply input range 15 21V AC or 18 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67086 software on your PC in order to perform the following Define the parameter of BACnet Defin...

Страница 10: ... tables below VAC VDC Vmin Vmax Vmin Vmax 15V 21V 18V 35V Consumption at 24V DC Device W VA HD67086 xxx B2 xxxMHz 0 3 5 Device No Load W VA Full Load W VA HD67086 xxx B2 xxxMHz 20 3 5 4 HD67086 xxx B2 xxxMHz 40 5 HD67086 xxx B2 xxxMHz 80 8 HD67086 xxx B2 xxxMHz 160 14 HD67086 xxx B2 xxxMHz 250 30 This value is with all the Slave M Bus devices of the code 20 40 80 160 250 connected to the line wire...

Страница 11: ...ing of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS...

Страница 12: ...ly 0 5Hz update in progress 2 wM Bus comm green Blinks quickly when data on wM Bus arrives Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 M Bus comm green only for HD67086 xxx B2 xxxMHz xxx Blinks quickly when a reply to a M Bus request arrives Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 BACnet comm Blinks quickly when BACnet communication is ru...

Страница 13: ...hernet connection must be made using Connector2 of HD67086 xxx B2 xxxMHz 0 or HD67086 xxx B2 xxxMHz xxx with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC ...

Страница 14: ...stor it is necessary to put dip 1 ON like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 82842 2x 24AWG stranded twisted pairs conductor foil shield braid shield Tasker p n C521 1x 24AWG twisted pair conductor foil shield braid shield Tasker p n C522 2x 24AWG...

Страница 15: ...standard telephone cable JYStY N 2 0 8 mm is used as the transmission medium for the M Bus The maximum distance between a slave and the repeater is 350m this length corresponds to a cable resistance of up 29Ω This distance applies for the standard configuration having Baud rates between 300 and 9600 Baud and a maximum of 250 slaves The maximum distance can be increased by limiting the Baud rate an...

Страница 16: ... that runs with Windows called SW67086 It is downloadable from the site www adfweb com and its operation is described in this document this manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 10 32 64bit When launching the SW67086 the window below appears Fig 2 Note It is necessary to have installed Net Framework 4 Fig...

Страница 17: ...figuration A device s configuration can also be imported or exported To clone the configurations of a Programmable M Bus M Bus Wireless BACnet Slave Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder wit...

Страница 18: ...hange the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67086 check automatically if there are up...

Страница 19: ... Bus Wireless BACnet Slave Document code MN67086_ENG Revision 1 100 Page 19 of 43 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the tables contained in the different sections of the software ...

Страница 20: ...s defined In the fields SUBNET Mask the SubNet Mask of BACnet IP side of the converter is defined In the fields GATEWAY the default gateway of the network is defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the port used for BACnet communication is defined The default port used for BACnet communication is 4...

Страница 21: ...he BACnet MS TP network number is defined If the field BACnet description up to 32 chars is checked the description for the BACnet Objects can be up to 32 chars long In the section Select Device it is possible to select the type of converter M Bus port present or not The means of the fields for wM Bus are In the field Mode it is possible to select the Communication Mode used for the M Wireless com...

Страница 22: ...mary ID or Secondary ID to makes the requests and then insert the Primary Address from 1 to 250 or the Secondary Address from 0 to 99999999 of M Bus device If the field Node State is checked the Status byte of the M Bus node is mapped into a BACnet Object If the field Identification Number is checked the Identification Number of the M Bus node is mapped into a BACnet Object In the field Swap Ident...

Страница 23: ...e If is selected By Type it is necessary to fill all fields in the section Variables with the correct values otherwise if By Position is selected it is possible to insert the progressive number of the variable ned page 32 for more information In the field Cut after it is possible to select after how many frames stops data requests It is used when the slave has got many data frames and you don t ne...

Страница 24: ...he following 16 fields you have to specify the key to decode the message If the field Node State is checked the Status byte of the M Bus node is mapped into a BACnet Object If the field Identification Number is checked the Identification Number of the M Bus node is mapped into a BACnet Object If the field RSSI is checked the RSSI of the signal is mapped into a BACnet Object If the field Convert BC...

Страница 25: ...ted By Type it is necessary to fill all fields in the section Variables with the correct values otherwise if By Position is selected you can insert the progressive number of the variable that you need page 32 for more information After that pressing the ADD NODE button a new node appears in the left side of the window In order to modify a created node it is necessary to select the desired node cha...

Страница 26: ...o use this field only if the Type of Data is VIF is in ASCII In the field Function Field it is necessary to select the type of data The field Dimension is used to select the dimension of the variable 8 16 24 32 32 real 48 64 bit Variable Length In the field Length Variable Len insert the length of the data in the case of the dimension is Variable Length In the field Unit if it is necessary it is p...

Страница 27: ...f it isn t nothing changes In the field BACnet Eng Unit it is possible to select a Engineering Unit of the Object by pressing to the button see BACNET ENG UNIT section for more details In the field Post Operation it is possible to select to do a math operation to the value Having completed this fields to add the variable the button ADD VARIABLE must be pressed In order to modify a created variable...

Страница 28: ... Len insert the length of the data in the case of the dimension is Variable Length If the field From BCD to Integer is checked the converter converts the BCD value of variable in Integer format This happens only if the variable is in BCD format if it isn t nothing changes In the field Position the position of the variable inside the M Bus frame sent by the M Bus slave is defined In the field BACne...

Страница 29: ...7 Status 0x00 Signature Byte 2of2 0x00 Signature Byte 1of2 0x04 DIF 0x79 VIF Identification 0x00 Data Byte 4of4 0x00 Data Byte 3of4 0x00 Data Byte 2of4 0x00 Data Byte 1of4 0x04 DIF 0x06 VIF Energy 0x00 Data Byte 4of4 0x00 Data Byte 3of4 0x00 Data Byte 2of4 0x00 Data Byte 1of4 0x44 DIF 0x06 VIF Energy 0x00 Data Byte 4Of4 0x00 Data Byte 3Of4 0x00 Data Byte 2Of4 0x00 Data Byte 1Of4 Other Variables 0x...

Страница 30: ...button of the mouse over an item Variable or Node it is possible to Copy Paste and Delete It is possible to Copy a variable from a Node and copy it to another Node or copy a Variable from a project and paste in another one It is also possible to copy an entire Node with all its Variables Note By pressing the Import Network button it is possible to import the file generated by the Analyzer HD67031 ...

Страница 31: ... or by selecting with the fields Select the Type and Select unit the Type Unit desired If the second way is used is necessary to press the Select Engineering Unit button for confirm the choice BACNET DATA TYPE When using the Variables List By Position is necessary to select the Data Type of the variable Is possible to select from these types Analog Input 1 DateTime 3 Positive Integer 2 String 4 Se...

Страница 32: ... _Volume Flow m3 h 1 _Volume Flow Ext m3 min 1 _Volume Flow Ext m3 s 1 _Mass Flow Kg h 1 _Flow Temperature C 1 _Return Temperature C 1 _Temperature Difference K 1 _External Temperature C 1 _Pressure bar 1 _Averaging Duration 1 _Actuality Duration 1 _Type of data in VIFE _Time Point 3 _VIF is in ASCII 2 _Unit for H C A 2 _Fabrication No 2 _ Enhaced Identification 2 _Bus Address 2 Function Field _In...

Страница 33: ...al sec s day s 2 _ Storage interval month s 2 _ Storage interval year s 2 _ Duration since last readout sec s day s 2 _ Start date time of tariff 2 _ Duration of tariff nn 01 11 min to day 2 _ Period of tariff sec s to day s 2 _ Period of tariff months s 2 _ Period of tariff year s 2 _ dimensionless no VIF 2 _ Volts 1 _ Ampere 1 _ Reset counter 2 _ Comulation counter 2 _ Control signal 2 _ Day of ...

Страница 34: ...of abs value only if negative contributions 2 _ upper lower limit value 2 _ of exceeds of lower upper limit 2 _ Date time of begin end of first last lower upper limit exceed 2 _ Duration of limit exceed 2 _ Duration of first last 2 _ Date time of first last begin end 2 _ Multiplicative correction factor 2 _ Additive correction constant unit of VIF offset 2 _ Moltiplicative correction factor 10 3 2...

Страница 35: ...mber Secondary Address 12345678 Address Register 1000 Convert BCD in Integer Identification Num not checked None Type 1 1000 0x1234 1000 0x5678 1001 0x5678 1001 0x1234 Identification Number Secondary Address 12345678 Address Register 1000 Convert BCD in Integer Identification Num checked None Type 1 1000 0x00BC 1000 0x614E 1001 0x614E 1001 0x00BC BACNET EDE FILE By Pressing the BACNET EDE FILE but...

Страница 36: ...e Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Dip Switch A in OFF position Turn ON the device If you know the actual IP address of the device you have to use this procedure Turn ON the Device with the Ethernet cable inserted Insert the ac...

Страница 37: ...PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program more than one device using the UDP Update you have to cancel the ARP table every time you connect a new device on Ethernet For do th...

Страница 38: ...the configurator software SW67086 It is possible to access to these functions by simple click on the button It has the following characteristics Possibility to scan M Bus network Automatic decode of M Bus telegrams Easy connection directly through the Ethernet port of the converters For the description of the function it is possible to refer to this manual www adfweb com download filefold SCAN DEC...

Страница 39: ...nic Devices ADFweb com S r l User Manual M Bus M Bus Wireless BACnet Slave Document code MN67086_ENG Revision 1 100 Page 39 of 43 MECHANICAL DIMENSIONS Figure 8 Mechanical dimensions scheme for HD67086 xxx B2 xxxMHz xxx ...

Страница 40: ...standard M Bus slaves 1 5mA consumption 80 M Bus Wireless port M Bus port up to 80 standard M Bus slaves 1 5mA consumption 160 M Bus Wireless port M Bus port up to 160 standard M Bus slaves 1 5mA consumption 250 M Bus Wireless port M Bus port up to 250 standard M Bus slaves 1 5mA consumption M Bus Wireless Frequency 169MHz M Bus Wireless communication 169 MHz 433MHz M Bus Wireless communication 43...

Страница 41: ...or M Bus Master device that supports up to 20 Slaves Order Code APW040 Power Supply for M Bus Master device that supports up to 40 Slaves Order Code APW080 Power Supply for M Bus Master device that supports up to 80 Slaves Order Code APW160 Power Supply for M Bus Master device that supports up to 160 Slaves Order Code APW250 Power Supply for M Bus Master device that supports up to 250 Slaves ...

Страница 42: ...ollection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise ...

Страница 43: ...lease do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired o...