background image

14

 

Cleaning and Maintenance

 

 

 

 

 

 

 

 

 

 

 

GENERAL

 

 

Clean the Gas LAVA ROCK GRILL regularly.  A clean Gas LAVA ROCK GRILL looks better, will last 

longer and will perform better. Carbonised grease on the surface or between the trivets, will hinder 

the transfer of heat from the cooking surface to the food.  This will result in loss of cooking 

efficiency. 

 

 

 

DO NOT use water on the trivets, burners while these items are still hot as warping and cracking may  

occur.  Allow these items to cool down and then remove for cleaning. 

The entire trivets burner can be dismantled for cleaning. 

NOTE:

 

 

 

DO NOT use abrasive detergents, strong solvents or caustic detergents as they could corrode or damage 

the Gas LAVA ROCK GRILL. 

 

In order to prevent the forming of rust on the trivets, and burners, ensure that any detergent or cleaning 

material has been completely removed after each cleaning. 

 

DAILY CLEANING

 

 

1.

 

The drip tray should be checked and emptied frequently to prevent overflow and spillage. 

Remove the drip tray while still warm so that the grease is in a liquid state.  Empty any grease 

from the trays and wash thoroughly in the same manner as any cooking utensil. 

2.

 

Remove the burner, the trivets and thoroughly clean the splash back, interior and exterior 

surfaces of the range with hot water, a detergent solution and a soft scrubbing brush. 

3.

 

Dry the Gas LAVA ROCK GRILL thoroughly with a dry cloth and polish with a soft dry cloth. 

 

 

NOTE

 

 

If the LAVA ROCK GRILL usage is very high, we recommend that the weekly cleaning procedure is 

carried out on a more frequent basis. 

 

Ensure that protective gloves are worn during the cleaning process. 

 

DO NOT use harsh abrasive detergents, strong solvents or caustic detergents as they will damage 

the grate and burners. 

 

Allow these items castings to cool and remove for cleaning. 

 

Parts protected by the manufacturer or his agent are not to be adjusted by the installer, unless the 

installer is an authorized service agent. 

 

Systematic checking and suitable cleaning of the inside of grill before it is lit in order to avoid the 

emission of fire from the oils that have accumulated during previous cooking. In the case of the use 

of a bed of lava stones or any other material generating  dust it is necessary to remember that 

regular cleaning of the burner outlets with a metal brush or any other such utensil recommended 

by the manufacturer, is necessary to avoid obstruction and to allow a good combustion. 

 

There is a bag of lava rock (about 2.5kg) in the appliance. Please put them evenly on bottom grate. 

 

 

Periodic Maintenance

 

 

NOTE:  All maintenance operations should only be carried out by a qualified service person.

 

 

To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts 

should be checked and adjusted periodically by a qualified service person.  If any small faults occur, have 

them attended to promptly.  Don't wait until they cause a complete breakdown.  

 

CAUTION:

 

 

Always turn off the gas supply before cleaning. 

This appliance is not water proof. 

Do not use water jet spray to clean this appliance. 

Содержание ECB-16S

Страница 1: ...ions for adapting the appliance to the conditions for use in that country WARNING For your safety do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation opera...

Страница 2: ......

Страница 3: ...lues Dimensions 6 Installation 7 Installation Requirements Unpacking Location Clearances Assembly Gas Connection LP Gas cylinder and compartment Commissioning Operation 12 Operation Guide Lighting Main Burners Turning OFF Main Burners Main burner air supply CAUTION Cleaning and Maintenance 15 General After Each Use Daily Cleaning Periodic Maintenance Trouble Shooting 17 Explosion Drawing 19 Parts ...

Страница 4: ...E POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS ...

Страница 5: ...e Read the instructions carefully before installation and using Warning Operation instruction must be placed in a conspicuous location When customers smell gas in the process of using should take safety precautions immediately Immediately turn off the main gas valve extinguish all heat and flames Safety information can be obtained from your local gas suppliers DO NOT SPRAY AEROSOLS IN THE VICINITY...

Страница 6: ...er s explicit authorization Manufacturers refused to undertake responsibility to third parties as the following reasons Not follow this instruction guidance and warning in using and testing Not in accordance with the requirements of technical parameters using this product Incorrectly or irrationally using the product by untrained personnel Not obey the local law using this product Be repaired or c...

Страница 7: ...ed The Gas LAVA ROCK GRILL Four Feet Instruction Manual The gas lava rock Product specification list Gas orifice dia Gas pres Total power ECB 48S ECB 36S ECB 24S ECB 16S G30 1 3mm 29mbar 6kWx4 6kW x3 6kW x2 6kW G30 1 2mm 37mbar 6kW x4 6kW x3 6kW x2 6kW G30 1 1mm 50mbar 6kW x4 6kW x3 6kW x2 6kW G20 2 2mm 20mbar 7 5kW x4 7 5kW x3 7 5kW x2 7 5kW G25 3 2 2mm 25mbar 7 3kW x4 7 3kW x3 7 3kW x2 7 3kW Pre...

Страница 8: ...5 Dimensions ...

Страница 9: ...ction from the appliance including all protective plastic coating from the exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor Ensure that the 4 adjustable feet are fitted with the protruding centre screw Report any deficiencies to the distributor who supplied the appliance Check that the available gas supply is correct ...

Страница 10: ... the Rating label The input rate should be checked against the available gas supply line capacity Particular note should be taken if the appliance is being added to an existing installation d The gas supply tubing or hose shall comply with the national requirements in force and shall be periodically examined and replaced as necessary e Only local national requirements rubber or PVC flexible hose N...

Страница 11: ...regulator refer to the picture of Install the Regulator A suitable jointing compound which resists the breakdown action of propane must be used on every gas line connection unless compression fittings are used 4 Check all gas connections for leakages 5 Check that the gas operating pressure NOTE The operating pressure to be measured at the manifold test point and with 2 burners operating at the Hig...

Страница 12: ...n well ventilation space Gas cylinder shall never be moved during operation period it shall be fixed with rigid support 2 If gas cylinder was inserted with compartment effective ventilation is provided by openings compartment base and upper side areas The total area of the openings in the upper part being at least 1 100th of the floor area of the compartment and that of the openings at the base be...

Страница 13: ...ted in the areas of correct lighting operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and a record of the Date of Purchase Date of Installation and the Serial Number of the Appliance must be recorded and kept with this manual These details can be found on the Rating label refer to the Gas Connection section NOTE If for some reason it i...

Страница 14: ...d operation practices can reduce the life of the appliance To use this appliance correctly please read the following sections carefully Lighting the Main Burner Turning off the Main Burner CAUTION This appliance is for professional use and is only to be used by qualified persons Only authorized service persons are to carry out installation servicing or gas conversion operation operations Component...

Страница 15: ...trol knob to the OFF position The main burner will extinguish Main burner air supply 1 For efficient burner operation a proper balance of gas volume and primary air supply must be maintained which will result in complete combustion Insufficient air supply results in a yellow streaming flame Primary air supply is controlled by an air shutter on the front of the burner 2 Loosen the screws on the fro...

Страница 16: ...ain burners to maintain the best function of the thermostat valve after turning off the main burners IMPORTANT Should any abnormal operation like ignition problems abnormal burner flame burner control problems partial or full loss of burner flame in normal operation be noticed the appliance requires IMMEDIATE service by a qualified service person and should not be used until such service is carrie...

Страница 17: ...OCK GRILL usage is very high we recommend that the weekly cleaning procedure is carried out on a more frequent basis Ensure that protective gloves are worn during the cleaning process DO NOT use harsh abrasive detergents strong solvents or caustic detergents as they will damage the grate and burners Allow these items castings to cool and remove for cleaning Parts protected by the manufacturer or h...

Страница 18: ... clean the interior and exterior surfaces of the Gas LAVA ROCK GRILL with hot water a mild detergent solution and a soft scrubbing brush Note that the gas control knobs are a push fit onto the gas control valve spindles and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discoloration may require a good quality stainless steel cleaner or stainless steel wo...

Страница 19: ...urned on and that bottles are not empty Call the service provider Nozzle occlusion Dredge nozzle Thermocouple connection loose Tighten thermocouple Thermocouple damage Replace thermocouple Gas control valve failure Replace control valve No spark flame on main burner Faulty battery for electronic pulse ignition device Put No 7 battery into ignition device Faulty electronic pulse ignition device Rep...

Страница 20: ...contact your nearest authorized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part by description and quote model number and serial number which is shown on the rating plate CAUTION Please replace the corresponding warning label that shows the gas type operated when the qualified pe...

Страница 21: ... 18 Explosion Drawing ECB 48S ...

Страница 22: ... 11 pressure test plug 4 12 inlet gas pipe 1 13 Adjustable steel foot 4 14 thermocouple fixation plate 4 15 thermocouple 4 16 ignitor pin with wire 4 17 U shape burner 4 18 Radiant plate 8 19 Radiant plate small 4 20 plate to increase height of grill 1 21 orifice 4 22 nut to fix angle 4 23 orifice fixation plate 4 24 angle connector for orifice 4 25 nut 4 26 10 clamp 8 27 10x400 corrugated pipe 4 ...

Страница 23: ... ECB 48S Imported By ADEXA DIRECT LIMITED GROUND FLOOR UNIT 1 214 PURLEY WAY CROYDON CR0 4XG LONDON UNITED KINGDOM Serial Number Year of Manufacture Brand ADEXA Application of Council Directive s EU 2016 426 9 March 2016 Standards EN 203 1 2014 EN 203 2 10 2007 EN 203 3 2009 I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Date 01...

Отзывы: