7

 

Installation

 

 

Clearances

 

NOTE:  Only non-combustible materials can be used in close proximity to this appliance. 

 

 

Combustible Surface

 

Non  Combustible  Surface

 

Left / Right Hand Side

Not applicable

150mm Min.

Rear 

Not applicable

150mm Min.

Bottom 

Not applicable

150mm Min.

Assembly 

NOTE:

 

 

This appliance is assembled before delivery except feet. 

 

 

This appliance is fitted with adjustable feet to enable the appliance to be positioned securely and level. 

 

 

Check all accessories complete. 

 

 

IM will be stated that the appliance shall be installed in such a way that side body surfaces are not 

accessible in the installed position. 

 

Gas Connection

 

 

NOTE:  ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.

 

 

1.

 

The Gas LAVA ROCK GRILL do not require an electrical connection, as they function totally on the 

gas supply only. 

2.

 

It is essential that the gas supply is correct for the appliance to be installed and that adequate 

supply pressure and volume are available.  The following checks should therefore be made before 

installation:- 

 

a.

 

Gas Type required for the appliance is shown in the rating label.  Check that this is correct for the gas 

supply the appliance is being installed for gas LAVA ROCK GRILL, The gas conversion is not suited for 

gas LAVA ROCK GRILL. 

 

b.

 

Supply Pressure required for this appliance is shown in the ‘Gas supply requirements’ section of this 

manual. Check the gas supply to ensure adequate supply pressure exists. 

 

c.

 

Input Rate of this appliance is stated on the Rating label .The input rate should be checked against the 

available gas supply line capacity. Particular note should be taken if the appliance is being added to an 
existing installation. 

 

d.

 

The gas supply tubing or hose shall comply with the national requirements in force and shall be 

periodically examined and replaced as necessary. 

 

e.

 

 Only local national requirements rubber or PVC flexible hose(Nominal core of hose shall be 6.3mm 

to12.5mm) could be used for LP gas connection. The length of flexible hose shall not be more than 
1.5meters. The flexible hose shall not come into contact with sharp edges.   

 

f.

 

 LP Gas Regulator, flexible hose adaptor and rubber gasket shall be matched with local national 

requirements; A Manual Isolation Valve must be fitted to the individual appliance supply line. The 

regulator should be certificated according to EN16129 latest version. And the hose should be 
Certificated according to the latest version EN 16436-1, BSEN ISO3821, BSEN1327 or DIN 1763 

g.

 

 Nature gas shall be connected with from nature gas supply pipe to nature gas regulator and connection 

adaptor to match with local national installation requirements. The nature gas supply line must be at 
least the equivalent of ½” (12.7 mm) iron pipe for single units, A Manual Isolation Valve must be fitted 
to the individual appliance supply line. 

 

h.

 

The appliance should be connected to the gas supply by means of Flexible hose or metal pipes --either 

rigid or flexible-- having an adequate diameter. When joining pipe fittings, never use oakum or Teflon 

as their residues could get to the valve and jeopardize its operation. Instead, interpose a seal gasket 
suitable for use in gas systems.  

 

Содержание ECB-16S

Страница 1: ...ions for adapting the appliance to the conditions for use in that country WARNING For your safety do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation opera...

Страница 2: ......

Страница 3: ...lues Dimensions 6 Installation 7 Installation Requirements Unpacking Location Clearances Assembly Gas Connection LP Gas cylinder and compartment Commissioning Operation 12 Operation Guide Lighting Main Burners Turning OFF Main Burners Main burner air supply CAUTION Cleaning and Maintenance 15 General After Each Use Daily Cleaning Periodic Maintenance Trouble Shooting 17 Explosion Drawing 19 Parts ...

Страница 4: ...E POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS ...

Страница 5: ...e Read the instructions carefully before installation and using Warning Operation instruction must be placed in a conspicuous location When customers smell gas in the process of using should take safety precautions immediately Immediately turn off the main gas valve extinguish all heat and flames Safety information can be obtained from your local gas suppliers DO NOT SPRAY AEROSOLS IN THE VICINITY...

Страница 6: ...er s explicit authorization Manufacturers refused to undertake responsibility to third parties as the following reasons Not follow this instruction guidance and warning in using and testing Not in accordance with the requirements of technical parameters using this product Incorrectly or irrationally using the product by untrained personnel Not obey the local law using this product Be repaired or c...

Страница 7: ...ed The Gas LAVA ROCK GRILL Four Feet Instruction Manual The gas lava rock Product specification list Gas orifice dia Gas pres Total power ECB 48S ECB 36S ECB 24S ECB 16S G30 1 3mm 29mbar 6kWx4 6kW x3 6kW x2 6kW G30 1 2mm 37mbar 6kW x4 6kW x3 6kW x2 6kW G30 1 1mm 50mbar 6kW x4 6kW x3 6kW x2 6kW G20 2 2mm 20mbar 7 5kW x4 7 5kW x3 7 5kW x2 7 5kW G25 3 2 2mm 25mbar 7 3kW x4 7 3kW x3 7 3kW x2 7 3kW Pre...

Страница 8: ...5 Dimensions ...

Страница 9: ...ction from the appliance including all protective plastic coating from the exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor Ensure that the 4 adjustable feet are fitted with the protruding centre screw Report any deficiencies to the distributor who supplied the appliance Check that the available gas supply is correct ...

Страница 10: ... the Rating label The input rate should be checked against the available gas supply line capacity Particular note should be taken if the appliance is being added to an existing installation d The gas supply tubing or hose shall comply with the national requirements in force and shall be periodically examined and replaced as necessary e Only local national requirements rubber or PVC flexible hose N...

Страница 11: ...regulator refer to the picture of Install the Regulator A suitable jointing compound which resists the breakdown action of propane must be used on every gas line connection unless compression fittings are used 4 Check all gas connections for leakages 5 Check that the gas operating pressure NOTE The operating pressure to be measured at the manifold test point and with 2 burners operating at the Hig...

Страница 12: ...n well ventilation space Gas cylinder shall never be moved during operation period it shall be fixed with rigid support 2 If gas cylinder was inserted with compartment effective ventilation is provided by openings compartment base and upper side areas The total area of the openings in the upper part being at least 1 100th of the floor area of the compartment and that of the openings at the base be...

Страница 13: ...ted in the areas of correct lighting operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and a record of the Date of Purchase Date of Installation and the Serial Number of the Appliance must be recorded and kept with this manual These details can be found on the Rating label refer to the Gas Connection section NOTE If for some reason it i...

Страница 14: ...d operation practices can reduce the life of the appliance To use this appliance correctly please read the following sections carefully Lighting the Main Burner Turning off the Main Burner CAUTION This appliance is for professional use and is only to be used by qualified persons Only authorized service persons are to carry out installation servicing or gas conversion operation operations Component...

Страница 15: ...trol knob to the OFF position The main burner will extinguish Main burner air supply 1 For efficient burner operation a proper balance of gas volume and primary air supply must be maintained which will result in complete combustion Insufficient air supply results in a yellow streaming flame Primary air supply is controlled by an air shutter on the front of the burner 2 Loosen the screws on the fro...

Страница 16: ...ain burners to maintain the best function of the thermostat valve after turning off the main burners IMPORTANT Should any abnormal operation like ignition problems abnormal burner flame burner control problems partial or full loss of burner flame in normal operation be noticed the appliance requires IMMEDIATE service by a qualified service person and should not be used until such service is carrie...

Страница 17: ...OCK GRILL usage is very high we recommend that the weekly cleaning procedure is carried out on a more frequent basis Ensure that protective gloves are worn during the cleaning process DO NOT use harsh abrasive detergents strong solvents or caustic detergents as they will damage the grate and burners Allow these items castings to cool and remove for cleaning Parts protected by the manufacturer or h...

Страница 18: ... clean the interior and exterior surfaces of the Gas LAVA ROCK GRILL with hot water a mild detergent solution and a soft scrubbing brush Note that the gas control knobs are a push fit onto the gas control valve spindles and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discoloration may require a good quality stainless steel cleaner or stainless steel wo...

Страница 19: ...urned on and that bottles are not empty Call the service provider Nozzle occlusion Dredge nozzle Thermocouple connection loose Tighten thermocouple Thermocouple damage Replace thermocouple Gas control valve failure Replace control valve No spark flame on main burner Faulty battery for electronic pulse ignition device Put No 7 battery into ignition device Faulty electronic pulse ignition device Rep...

Страница 20: ...contact your nearest authorized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part by description and quote model number and serial number which is shown on the rating plate CAUTION Please replace the corresponding warning label that shows the gas type operated when the qualified pe...

Страница 21: ... 18 Explosion Drawing ECB 48S ...

Страница 22: ... 11 pressure test plug 4 12 inlet gas pipe 1 13 Adjustable steel foot 4 14 thermocouple fixation plate 4 15 thermocouple 4 16 ignitor pin with wire 4 17 U shape burner 4 18 Radiant plate 8 19 Radiant plate small 4 20 plate to increase height of grill 1 21 orifice 4 22 nut to fix angle 4 23 orifice fixation plate 4 24 angle connector for orifice 4 25 nut 4 26 10 clamp 8 27 10x400 corrugated pipe 4 ...

Страница 23: ... ECB 48S Imported By ADEXA DIRECT LIMITED GROUND FLOOR UNIT 1 214 PURLEY WAY CROYDON CR0 4XG LONDON UNITED KINGDOM Serial Number Year of Manufacture Brand ADEXA Application of Council Directive s EU 2016 426 9 March 2016 Standards EN 203 1 2014 EN 203 2 10 2007 EN 203 3 2009 I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Date 01...

Отзывы: