TAMPER_1 / Green
IMPULSE_1 / White
GND / Brown
5.3. Mounting the counters on the screw terminals
Once the nut and packing seal are installed, the strands of the meter cable can be connected to the screw terminals of the product.
Below is the identification of each terminal block:
Note:
Up to 2 meters of the same type can be used in parallel.
Below is a description of the terminal blocks:
Meter with 2-wire output
TAMPER_2 / Yellow
IMPULSE_2 / Black
GND
IMPULSE_1 / White
GND / Brown
IMPULSE / BF
GROUND / GND
In this configuration, it is necessary to deactivate the input TAMPER of A-channel (register 320 bit 3 = 0) and preferably deactivate B-channel
(register 320 bit 4=0) which is not no used.