3.3. AT commands
A command starts with 2 ASCII characters: “AT”, followed by one or more characters and data (see the list below
for the syntax of AT commands available on the modem).
Each command must finish with a “CR” or “CR” “LF” – both are acceptable.
(CR indicates: Carriage Return, LF indicates: Line Feed)
Once the command has been received, the modem will feedback:
<cr><lf> “Data” for ATS type playback control <n> ?, AT/S or AT/V
“O” <cr><lf>, for any other command when this has been accepted.
“E” <cr><lf>, if it refuses the command due to a syntax error, unknown command, unknown range, invalid pa-
rameter, etc.
“CM” <cr><lf>, if it accepts the input in command mode
Table of AT commands:
Command
Description
Reply example
+++
Input request in command mode
CONNECTING... <cr><lf>
CM<cr><lf>
ATPIN <PIN>
Gives access to AT commands if regis-
ter S304 is different of 0
AT/V
Feeds back the version of the APPLICA-
TIF and RTU software
APP_8230EAA_PRG1706_V01.02.02:RTU_RTU_
WMBUS_868_PRG_1601_V00.00.03
Or
APP_8181AAA_PRG1701_V01.00.02:R-
TU_8120AAB_PRG_1701_V01.00.01
AT/N
Feeds back the type of network
"LoRa" or "SIGFOX" or « WMBUS »
ATS<n>?
Feeds back the content of the n range
Sn=y where y represents the content of the n
range
AT/S
Edits the content of all of the user rang-
es in the form of a list.
/
ATS<n>=<m>
Transfers the m VALUE to the n range
«O»<cr><lf> if Ok, «E»<cr><lf> if error,
«W»<cr><lf> if coherency error
AT&W
Saves the current configuration to
non-volatile memory.
«O»<cr><lf>, «E»<cr><lf> if coherency error
ATO
Exit command mode
«O»<cr><lf>, «E»<cr><lf> if coherency error
ATT63 PROVIDER
Unblock the operating range
«O»<cr><lf>
Example of a set of commands and corresponding responses that can be seen on the terminal:
Syntax
of the order
Description
Response Syntax to Next Line
+++
Input request in command mode
CONNECTING...
CM
ATS317=0
Deactivation of the respect of the Duty
Cycle
E -> This command is not validated (register
no unlocked)
ATT63 PROVIDER
Unblock the operating range
O
ATS317=0
Deactivation of the respect of the Duty
Cycle
O
ATS317?
Feeds back the value of the S202 range
S317=0
AT&W
Memory request for the state range
O
ATO
Output request in command mode
O
Interpreting the previous example: the user wanted to deactivate the respect of the Duty Cycle after having made
an unauthorized command (answer E), and the registers were unblocked in order to modify the register. The regis-
ter S317 was verified and the parameters were saved before exiting. When exiting command mode, the device will
start a new cycle of emission.