4.2.3 Network configuration information frame
During the passage into operation mode (from the Park or Command Mode), the following frame (0x20) representing the network configuration
of the product is transmitted:
0
1
2
3
4
5
6
7
8
9
10
Code
Status
PAYLOAD
0x20
Cf Status
S200
S201
X
X
X
X
X
X
X
0x20
0x42
0x18
0x01
Description of the frame:
• Byte 2: S200 register, WMBUS channel
• Byte 3: S201 register, frame format
In the example in grey this gives:
• Byte 2=0x18: the WMBUS channel is 24
• Byte 3=0x01: the frame format is B
4.2.4 Keep Alive frame
This frame (0x30) is transmitted only in the event mode at the frequency defined by register 300.
0
1
2
3
4
5
6
7
8
9
10
Code
Status
PAYLOAD
0x30
Cf Status
ADR
Value read on the channel A sensor
S322
Value read on the channel B sensor
X
0x30
0x42
0x01
0x0C3500
0x01
0x4C4B40
Description of the frame:
• Byte 2: Type of the sensor on channel A. Configured by the user (register 320).
• Bytes 3 to 5: Value measured on channel A.
• If the type of sensor is 0-10V: The value is expressed in µV
• If the type of sensor is 4-20mA: The value is expressed in nA
• Byte 6: Type of the sensor on channel B. Configured by the user (register 322).
• Bytes 7 to 9: Value measured on channel B.
• If the type of sensor is 0-10V: The value is expressed in µV
• If the type of sensor is 4-20mA: The value is expressed in nA
In the example in grey this gives:
• Byte 2=0x02: register 320, channel A configured for a 4-20mA sensor
• Bytes 3 to 5=0x0C3500=800,000 in decimal i.e. A value measured on channel A of: 800,000,x10=8,000,000nA i.e. 8mA
• Byte 6=0x01: register 322, channel B configured for a 0-10V sensor
• Bytes 7 to 9=0x4C4B40=5,000,000 in decimal i.e. a value measured on channel B of: 5,000,000 µV i.e. 5V
4.2.5 Data Frame
This frame (0x42) contains the values measured on the different sensors
0
1
2
3
4
5
6
7
8
9
10
Code
Status
PAYLOAD
0x42
Cf Status
S320
Value read on the channel A sensor
S322
Value read on the channel B sensor
X
0x42
0x42
0x02
0x0C3500
0x01
0x4C4B40
Содержание LoRaWAN 863-870 ANALOG 868 ARF8190BA
Страница 5: ...FR WMBUS ANALOG PWR Guide utilisateur User guide version V2 0 1 5 Page of 83 FR FRANCAIS ...
Страница 42: ...EN WMBUS ANALOG PWR Guide utilisateur User guide version V2 0 1 42 Page of 83 FR ENGLISH ...
Страница 79: ...WMBUS ANALOG PWR Guide utilisateur User guide version V2 0 1 79 Page of 83 DE FR DEUTSCH Vorschriften ...