EN
sigfox RC2 Pulse - Guide utilisateur / User guide version V1.0.0
71
Page
of 99
FR
3.3. AT commands
A command starts with 2 ASCII characters: “AT”, followed by one or more characters and data (see the list below for the syntax of AT com-
mands available on the modem).
Each command must finish with a “CR” or “CR” “LF” – both are acceptable.
(CR indicates: Carriage Return, LF indicates: Line Feed)
Once the command has been received, the modem will feedback:
<cr><lf> “Data” for ATS type playback control <n> ?, AT/S or AT/V
“O” <cr><lf>, for any other command when this has been accepted.
“E” <cr><lf>, if it refuses the command due to a syntax error, unknown command, unknown range, invalid parameter, etc.
“CM” <cr><lf>, if it accepts the input in command mode
Table of AT commands:
Command
Description
Reply example
+++
Input request in command mode
CONNECTING... <cr><lf>
CM<cr><lf>
ATPIN <PIN>
Gives access to AT commands if register S304 is different of 0
AT/V
Feeds back the version of the APPLICATIF and RTU software
APP_8230EAA_PRG1706_V01.02.02:RTU_RTU_
WMBUS_868_PRG_1601_V00.00.03
Ou selon la version du réseau
APP_8181AAA_PRG1701_
V01.00.02:RTU_8120AAB_PRG_1701_V01.00.01
AT/N
Feeds back the type of network
"LoRa" ou "SIGFOX" or « WMBUS »
ATS<n>?
Feeds back the content of the n range
S<n>=<y><cr><lf> with <y> as the register
content
AT/S
Displays the content of all of the user ranges in the form of a
list.
/
AT/d
Displays all registers (user, network, production)
/
ATS<n>=<m>
Transfers the m value to the n range
«O»<cr><lf> if Ok, «E»<cr><lf> if error,
«W»<cr><lf> if coherency error
AT&W
Saves the current configuration to non-volatile memory.
«O»<cr><lf>, «W»<cr><lf> if coherency error
ATO
Exit command mode
«O»<cr><lf>, «W»<cr><lf> if coherency error
ATT63 PROVIDER
Unblock the operating range
«O»<cr><lf>
Example of a set of commands and corresponding responses that can be seen on the terminal:
Syntax
of the order
Description
Response Syntax to Next Line
+++
Input request in command mode
CONNECTING...
CM
ATS317=0
Deactivation of the respect of the Duty Cycle
E -> This command is not validated (register no unloc-
ked)
ATT63 PROVIDER
Unblock the operating range
O
ATS317=0
Deactivation of the respect of the Duty Cycle
O
ATS317?
Feeds back the value of the S202 range
S317=0
AT&W
Memory request for the state range
O
ATO
Output request in command mode
O
Interpreting the previous example: the user wanted to deactivate the respect of the Duty Cycle after having made an unauthorised command
(answer E), and the registers were unblocked in order to modify the register. The register S317 was verified and the parameters were saved
before exiting. When exiting command mode, the device will start a new cycle of emission.
Содержание FIELD TEST DEVICE - sigfox RC2
Страница 6: ...FR sigfox RC2 Pulse Guide utilisateur User guide version V1 0 0 6 Page of 99 FRANCAIS ...
Страница 51: ...EN sigfox RC2 Pulse Guide utilisateur User guide version V1 0 0 51 Page of 99 FR ENGLISH ...
Страница 95: ...sigfox RC2 Pulse Guide utilisateur User guide version V1 0 0 95 Page of 99 DE FR DEUTSCH Vorschriften ...