Ref. 08-07-V6-lmn
p. 6
A
RF54
User Guide
Description Min Max
Unit
Vil1
Input low voltage except
/RESET
-0.5 0.3VDD
V
Vih1
Input High voltage except
/RESET
0.6VDD VDD+0.5
V
Vil2
/RESET Input low voltage
-0.5
0.2VDD
V
Vih2
/RESET Input High voltage
0.9VDD
VDD+0.5
V
/RESET
pulse
width 2.5
- µs
General purpose I/O extended functionality
RS485 interface
The S215 register allows enabling the management of the control lines (/RE
and DE lines) of most RS485 buffer. The following figures illustrate the
RS485 wiring and the configuration required for activating the DE and /RE
management. Even one line is sufficient, for more flexibility two different
lines could managed the DE and RE RS485 control lines. Hereafter a
connection example with both lines or one line only.