![Adeunis RF ARF53 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/adeunis-rf/arf53/arf53_user-manual_2850757021.webp)
A
RF53
User Guide
Ref.
08-07-V6-lmn
p
19
Type Regi
ster
Function Description
Default
value
Note
R/W
S219 RS485 delay
Delay between DE activation and the
first RS485 transmitted byte
From 0 up to 160
3
Protocol
R/W
S220 Protocol
‘2’= hopping all the band
‘
3’= hopping low band
‘
4’= hopping high band
2
R/W S221
Packet
retries Number of radio packet retries
From 0 up to 2. It is mandatory to
set
S216 to 0 (hardware RTS) if
S221 = 1 or 2.
0
R/W S252
Reception
address
From 0 up to FFFF
Used in addressed protocol only, for
filtering incoming frame
0000
R/W S256
Transmission
address
From 0 up to FFFF
Used in addressed protocol only, added
to out coming frame
0000
Miscellaneous
R/W
S205 Pin code
Pin code value
Value 0000 is not allowed
1111
R/W S207
Pin
code
activation
0 pin code disabled
1 pin code enabled
0
N
OTE
1
when a serial speed change is requested, the S214 register value can be
automatically set to a value greater or equal than the duration of three
characters in the requested speed.
N
OTE
2
If the radio rate is equal to the serial baudrate, the radio packet is longer
than the serial frame, due to radio protocol overhead. If the current radio
rate is 10 kbit/s (Narrow band), a serial baudrate of 4800 bauds can be used