![Adeunis RF ARF33-PRO Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/adeunis-rf/arf33-pro/arf33-pro_user-manual_2850753044.webp)
43
208210A_UG_V1.6_ARFx3-PRO
R/W
S219
RS485 delay
Delay between DE activation and
the first RS485 byte transmitted
from 0 to 160
3
Protocol
R/W
S220
Protocol
«1» = transparent mode
«6»= addressed
6
R/W
S252
Reception address from 0 to FFFF
Used in addressed protocol only, in
order to filter the incoming frame.
0xFFFF reserved for transmission
(additional information in “repeater
application note”)
R/W
S256
Transmission
address
from 0 to FFFF
Used in addressed protocol only, in
order to filter the outgoing frame.
Protocol
R/W
S205
Pin Code
Pin Code value
The value 0000 is not possible
1111
R/W
S207
Pin Code activa-
tion
0 Pin code deactivated
1 Pin code activated
0
Function
repeater
R/W
S244
Repeater number
from 0 to 100
0: repetition is not enabled (default
value)
1-100 -> repeater enabled; this
value is used to define the waiting
period before transmission
(additional information in “repeater
application note»)
0
R/W
S250
Forced repetition
0 -> Conditional repetition
1 -> Unconditional repetition
(additional information in “repeater
application note”)
0
R/W
S300
RSSI serialization
0-> no serialized RSSI
2 -> serialized RSSI
0
6
NOTE 1
When a change of serial speed is requested, the values of the S214 and S217 registers are automatically set to
a value greater than or equal to the period of three characters at the speed requested (13 ms for 2400 bauds, 7
ms for 4800, otherwise 3 ms)
NOTE 2
Transmission mode without flow control. Please note that using a serial transmission rate that is higher than the
radio transmission rate will of necessity lead to the loss of characters in the absence of flow control.
If the radio transmission rate is equal to the serial transmission rate, the radio frame is longer than the serial
frame due to the header required by the radio protocol; but the radio header will only be generated at the start of
the radio transmission and this header will be absorbed by the size of the internal buffer.
For example, if the current radio transmission rate is 10 kbits/s, a serial transmission rate of 9600 must be used
without flow control, while a serial transmission rate of 19,200 (with 10 kbits/s for the radio transmission rate) will
produce a data overflow.
Содержание ARF33-PRO
Страница 7: ...6 208210A_UG_V1 6_ARFx3 PRO FRANCAIS ...
Страница 28: ...27 208210A_UG_V1 6_ARFx3 PRO ENGLISH ...
Страница 48: ...47 208210A_UG_V1 6_ARFx3 PRO DEUTSCH ...
Страница 69: ...68 208210A_UG_V1 6_ARFx3 PRO ITALIANO ...