background image

IF YOU HAVE...

Page 2

Install product as supplied.

Patented New Zealand No. 605175 

INSTALLING THE VENTURI JET:

Using the Allen Key provided, screw the Venturi Jet into the inlet thread end first.

The Allen Key is a tight fit and will require a hard push to fully engage in the jet.

Ensure the Venturi Jet

is screwed in firmly thread

end first until the mark

on the key aligns with the

end of the mixer outlet.

IMPORTANT

Please note:

Do not throw away the other

Venturi Jets as they may be

required at a later date. 

Ask the homeowner to keep

with the warranty information.

(A)

(B)

(C)

2. Follow this flowchart to select the correct Venturi Jet for the pressure situation:

20-35kPa 

GREEN

 JET

Recommended for 20-35kPa

hot water supply.

36-75kPa 

YELLOW

 JET

Recommended for 36-75kPa 

or greater hot water supply.

Please note:

 Performance of the mixer will vary based on the specific pipework between your hot water source and the outlet.

76-130kPa 

RED

 JET

Recommended for 76-130kPa 

or greater hot water supply.

1. Check your hot & cold water pressure

EQUAL LOW PRESSURE OR EQUAL HIGH/MAINS PRESSURE

UNEQUAL PRESSURE

START:

Unknown Water Pressure

Yellow Jet

(Hot water pressure 20kPa – 130kPa)

150 - 500kPa

Green Jet

Yellow Jet

Red Jet

COLD WATER PRESSURE:

More than 500kPa

Yellow Jet

(Hot water pressure 20kPa – 130kPa)

20 - 35kPa

76 - 130kPa

HOT WATER PRESSURE:

36 - 75kPa

Содержание SOL FUSION PLUS

Страница 1: ...at pressures above 500kPa can cause damage from water hammer reduce the life of appliances taps fittings cause excessive noise in the system and recommend that a pressure limiting valve PLV be fitted 3x Venturi Jets for Unequal Pressures 36 75kPa YELLOW JET 76 130kPa RED JET BEFORE INSTALLATION MIXER ORIENTATION Pipework MUST be purged before connecting to the mixer This mixer is designed to be conn...

Страница 2: ...A B C 2 Follow this flowchart to select the correct Venturi Jet for the pressure situation 20 35kPa GREEN JET Recommended for 20 35kPa hot water supply 36 75kPa YELLOW JET Recommended for 36 75kPa or greater hot water supply Please note Performance of the mixer will vary based on the specific pipework between your hot water source and the outlet 76 130kPa RED JET Recommended for 76 130kPa or great...

Страница 3: ... New Zealand No 605175 HOW TO INSTALL 1 No minimum straight distance HOT supply only COLD supply only 3 Apply a silicone bead on the back of the faceplate Cut a hole to suit faceplate Ø90mm Faceplate Min 40mm Max 70mm ...

Страница 4: ...sition as shown in Figure 1 6 Remove the handle and disassemble the mixer 1 Unscrew the Venturi Jet using a 2 5mm Allen Key 3 Refit the correct Venturi Jet into the insert disc and hand tighten firmly 4 Refit the seal with silicone grease if required and then insert disc using the long nose pliers ensuring that the locating pins go into the corresponding sockets 5 Page 4 Locating pin socket FRONT ...

Страница 5: ...pin Reassemble mixer Ensure that both black lines marked on the cartridge and cartridge nut are aligned when the mixer is in full cold position as shown in Figure 1 5 Locating pin Refit the seal with silicone grease if required and then insert disc using the long nose pliers ensuring that the locating pins go into the corresponding sockets Patented New Zealand No 605175 FULL COLD POSITION Figure 1...

Отзывы: