– 10 –
✱
81
ZONE LISTS FOR OUTPUT DEVICES (01 - 03); Cross Zones (04); and Night-Stay Zones (05). This is an interactive
mode. Fill in the required data on the worksheet below and follow the procedure in the installation manual as you
enter the data in response to the displays and prompts that appear in sequence.
Note:
Record desired zone numbers below. More or fewer boxes than shown may be needed, since any list may
include any or all of system's zone numbers.
Zone List 01: Started or stopped by zone numbers (enter 00 to end entries).
,
,
,
,
,
,
,
,
,
...etc.
Zone List 02: Started or stopped by zone numbers (enter 00 to end entries).
,
,
,
,
,
,
,
,
,
...etc.
Zone List 03: Started or stopped by zone numbers AND/OR assignment of Chime zones (enter 00 to end entries).
,
,
,
,
,
,
,
,
,
...etc.
Zone List 04: Cross Zone list: An alarm will occur if the system is armed and two or more of these active burglary
zones (Entry/Exit 1 or 2, Interior Follower, Perimeter, Trouble Day/Alarm, Night, or Interior w/ Delay) remain faulted
after Cross Zone time has expired, and this mode is enabled.
,
,
,
,
,
,
,
,
,
...etc.
NOTE: This Zone List 04 is not to used in UL installations.
Zone List 05: Night Stay Zones: These interior zones (Interior Follower or Interior w/ delay) will be armed when
arming the system in the Night-Stay mode.
,
,
,
,
,
,
,
,
,
...etc.
NOTE: Zone 92, DURESS, must not be programmed into any Zone List.