background image

14

0 = OMIT ZONES

[ent] to Select

6

6 = Walk Test

ent to select

ent

PIN + ent

1=TEST ALL ZONES

2=SELECTED ZONES

1

NO ENTRIES

WALK TEST ACTIVE

ESC to abort

1001 FINAL

#=TEST ENT=START

2

>A

1002 EXIT

#=TEST ENT=START

1002 EXIT

TEST ENT=START

#

ent

Walk Test (User Level 5 and Above)

Purpose

The 

Walk Test

 option provides a method of testing the zones to

ensure that they are operating correctly. There are two options
available:
1. All zones can be tested
2. Selected zones can be tested

In both cases the sounder indicates an open zone. The test is recorded
in the log. Wire-free zones also show the received signal strength as a
percentage

Selecting Walk Test

Enter the QUICK MENU. Press the key 6 followed by the ent key. When
Walk Test is selected, 

Test All Zones

 or 

Selected Zones

 displays.

All Zones

Choosing 

All Zones

 (press key 1) starts the test immediately. No

selection is necessary as all valid zones are included in the test. The
sounder operates whenever a zone is opened and stops when all
zones are closed.

Note:

The Test All Zones option only tests zones which can

be omitted from the system.

Selected Zones

Choosing the Selected Zones option by pressing key displays the first
zone on the system. Each zone is displayed in turn by using the >A or
<B keys. When the zone to be included in the test is displayed, press the
key. Other zones can be included in the test in the same manner. When
all of the required zones have been selected, press the ent key to start
the Walk Test.

Note:

The Selected Zones option includes non-omittable
zones.

Ending Walk Test

To abort the walk test option press the esc key, otherwise the walk test
option remains active for 20 minutes after the last key press.

Содержание galaxy 128

Страница 1: ...User Guide 8 18 60 128 500 504 512...

Страница 2: ......

Страница 3: ...r Level 3 6 3 Setting groups 3 Exit time 3 Sounder 4 Zones Open 4 Final Door Terminator 4 System Set 4 Part Setting 4 Cancelling The Setting 4 Group Name 4 MICROMAX SETTING OPTIONS 5 Setting with the...

Страница 4: ...Set 10 Non omittable Zones 10 Chime User Level 3 and Above 11 Purpose 11 Selecting Chime 11 Chime In Operation 11 Display Zones User Level 4 and Above 11 Purpose 11 Selecting Display Zones 11 Address...

Страница 5: ...cting Codes 17 User Codes 17 Modify Pin 17 Modify Level 18 Duress Code 18 Quick Menu 19 Modify Name 19 Time Zone Galaxy 60 128 500 504 and 512 19 Temporary Codes Galaxy 128 500 504 and 512 20 Pin Chan...

Страница 6: ...MESSAGES 28 Other Keypad In Use Galaxy 8 And 18 Only 28 Alarm In Progress 28 PA Reset Required 28 Manager Reset Required 28 Engineer Reset Required 28 No Entries 28 Invalid Selection 28 Invalid Code...

Страница 7: ...the latest software and hardware technology First and foremost the Galaxy meets all your security needs The engineer will program and commission the system to your own exacting requirements Warning Th...

Страница 8: ......

Страница 9: ...must identify themselves with a Personal Identification Number PIN This number is a 4 5 or 6 digit number selected from keys 0 9 The number keys are also used where groups are programmed on the syste...

Страница 10: ...de additional features for certain options e g printing the event log or deleting entries Power LED The green power LED remains lit whenever the keypad is connected to a mains power supply A mains pow...

Страница 11: ...p is displayed on the keypad screen Possible status options are R Ready Groups is unset and all zones are closed F Faulted Group is unset and at least one zone is open S Set Group is set L Lockout Gro...

Страница 12: ...tting routine The ESC TO ABORT message will flash as a reminder Final Door Terminator The setting procedure can be manually completed by either closing the FINAL door or by pressing the TERMINATOR but...

Страница 13: ...sed to select the group for setting after swiping the card Dual Focus If a is assigned to a particular users pin and their max card number then the user will have dual focus operation This means that...

Страница 14: ...ns to pulse quickly when 75 of the entry time has elapsed indicating time is running short Cancelling Alarms To cancel an alarm enter a valid PIN followed by ent at the keypad The keypad displays deta...

Страница 15: ...n i r P 4 2 e c a r T 4 4 4 t n i r P 5 e m i h C 5 1 s s e c c A 5 2 s r o o D r e m i T 5 4 l o r t n o C 5 t s e T k l a W 6 t e S t n a t s n I 6 1 p u o r G 6 4 t i m O 6 7 e t a D e m i T t n a...

Страница 16: ...l Menu The Full Menu has a hierarchy of four structures contained within it Each structure is acces sible by an increased user code level Quick Menu The Quick Menu offers users level three and above a...

Страница 17: ...A and B keys can then be used to select other zones to be omitted using the same method Note A zone is omitted from the system as soon as the key is pressed The system does not have to be set Setting...

Страница 18: ...e initiating keypad A warning is given ten and five minutes before the zones are reinstated The ATM Time out period can be extended by entering an ATM code and selecting 1 Reset Access To manually rei...

Страница 19: ...1 AND 0 can also be used to select ON and OFF respectively Chime In Operation When switched ON the Chime mode remains active until switched OFF again Zones that have been programmed with the chime att...

Страница 20: ...500 504 and 512 enter the line RIO and zone number 4 digits Press the key to display the zone resistance and RIO voltage Escape The esc key aborts the option and returns to the option menu Display Lo...

Страница 21: ...unity to get a hard copy print out of the system details This option requires a serial printer to be connected to the system Selecting Print Enter the QUICK MENU Press key 5 followed by the ent key Th...

Страница 22: ...l Zones or Selected Zones displays All Zones Choosing All Zones press key 1 starts the test immediately No selection is necessary as all valid zones are included in the test The sounder operates whene...

Страница 23: ...urs and minutes HH MM When the new time is entered the display immediately returns to the time or date selection screen The system does not accept invalid times greater than 23 hours greater than 59 m...

Страница 24: ...programmed Pin Change date Note The valid period for Pin Change codes is programmed by the installation engineer 3 Max Users Pre V4 Only This option is only available if the MAX mode is enabled The op...

Страница 25: ...ent key to accept the programming and return to the previous menu level When a PIN has been assigned to a user number a solid box n is displayed on the line of the user number details screen Deleting...

Страница 26: ...c h c i h w l e v e l d e x i f a s a h e d o c r e g a n a m e h T Modify Level Each user is assigned an access level which determines the menu options available to the user see p 7 Table 1 Menu Opti...

Страница 27: ...fy Name option a section of the alpha numeric that can be assigned to the user name is displayed on the bottom line of the keypad the cursor flashes on the letter L Press to erase the letters of the d...

Страница 28: ...stead of a number of days for a temporary code Press the ent key to accept the programming and return to the previous menu level A code assigned as a PIN Change code is indicated on the user code disp...

Страница 29: ...to Group 1 Pressing the group number toggles the group assigned to the user e g Pressing 2 and 3 assigns Groups 2 and 3 to the user Pressing 1 while group 1 is already assigned removes group 1 from t...

Страница 30: ...ue 10 digit number laser etched onto it A MAX card is assigned to a user by entering this number in the Max No option The number identifies the MAX card to the system and refer ences it to the user it...

Страница 31: ...or B key to select the required keypad and press the ent key to accept the programming Note A black flashing square over the first digit of the keypad address indicates the address of the keypad curre...

Страница 32: ...A MAX number can be assigned to a user code that does not have a PIN allocated to it All other options for this user are valid for the MAX card It is recommended that MAX numbers should be assigned t...

Страница 33: ...1 is already assigned removes group 1 from the MAX user press the ent key to accept the programming and return to the previous menu level Galaxy 500 504 and 512 The Galaxy 500 has 16 groups the 504 an...

Страница 34: ...ng systems These should be switched off if possible 4 Always follow the exit entry route procedure agreed with your alarm installer 5 Treat the alarm components with care to ensure they are not damage...

Страница 35: ...o i t c n u F n o i t p i r c s e D e m i h C t i m O t r a P 1 2 3 4 5 6 7 8 1 1 0 1 2 1 0 1 3 1 0 1 4 1 0 1 5 1 0 1 6 1 0 1 7 1 0 1 8 1 0 1 e n o Z n o i t c n u F n o i t p i r c s e D e m i h C t...

Страница 36: ...red The system has been programmed for engineer reset following an alarm activation The engineer must be called to reset the system before the user can set the alarm Tamper alarms usually require an e...

Страница 37: ...29 Name Address Telephone Office Hours Other Times Account No INSTALLER DETAILS...

Страница 38: ...30 IU1 0022 Rev 2 Ademco Microtech Ltd 3 Wellington Crescent Fradley Park Lichfield Staffs WS13 8RZ Adivision of the Pittway Corporation Copyright Pittway Corp...

Отзывы: