ADEMCO FlexGuard 5852 Скачать руководство пользователя страница 4

 

 

5852-004-V0

9.7 mm

(.38")

M4 or M5
(#8 or #10)

 

Figure 5.  Tamper Switch 

 

MAINTAINING PROPER OPERATION 

To maintain the 5852 sensor in proper working condition, it is 
important to observe the following: 

1. 

Replace the battery when the system indicates that the 5852 
has reported a low battery condition.  

2.  Units should never be relocated without the advice or 

assistance of the alarm service company. 

3.  Fans, air conditioners, blowers, loudspeakers, or other 

sources of vibration and sound should not be introduced 
into the protected area after installation of sensors.  If this 
is unavoidable, the alarm service company should be 
notified and the system should be readjusted/re-tested.  

 

SPECIFICATIONS 

Types of Glass: 

Ordinary Plate, Tempered, Wired Plate, and 
Laminated 

 

NOTE:

  The 5852 is NOT recommended 

for protection of glass areas less than 

 

10-7/8 inches by 10-7/8 inches. 

Power: 

Single 9V Lithium Battery:  Use only 
UltraLife U9VL-J. 

WARNING:

  Risk of fire, explosion, and 

burns.  Do not recharge, disassemble, 
incinerate, or heat above 212° F (100° C). 
Dispose of used batteries promptly.  Keep 
away from children. 

Range: 

Within 25 feet (7.6 m) of farthest protected 
glass 

Operating Temp:  32° to 120° F 

Dimensions: 

4.75" L x 4.13" W x 1.25" D  (70mm x 
125mm x 27mm) 

Accessories: 

Ademco GBS7 or Intellisense FG-701 
(not supplied)  Glassbreak Simulator 

 

Nominal Thickness 

Glass Type

Minimum Maximum 

Plate 

2.4 mm (3/32 in.) 

10 mm (3/8 in.) 

Tempered 

3 mm (1/8 in.) 

10 mm (3/8 in.) 

Laminated

1

 

3 mm (1/8 in.) 

14 mm (3/8 in.) 

Wired 

6 mm (1/4 in.) 

6 mm (1/4 in.) 

Coated

2

 

3 mm (1/8 in.) 

6.4 mm (1/4 in.) 

Sealed 
Insulating

1

 

3 mm (1/8 in.) 

6 mm (1/4 in.) 

(Maximum overall 7/16 in.) 

Minimum size for all types is 28 cm (11 in.) square; glass 
must be framed in the wall or mounted in a barrier at least 
0.9 m (36 in.) wide. 

Protected only if both plates of the unit are broken. 

2

 

Coated glass with security films, including films for solar 
protection, up to 12 mil. thick may be used.  The Glass-Gard 
GGLL 1200 has been evaluated with this product by 
Underwriters Laboratory, Inc. 

 

FCC NOTICE 

FCC ID:  CFS8DL5850 

This device complies with Part 15 of FCC rules.  Operation is 
subject to the following two conditions:  (1) This device may 
not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause 
undesired operation. 

 

TO THE INSTALLER 

Regular maintenance and inspection (at least annually) by the 
installer and frequent testing by the user are vital to continuous 
satisfactory operation of any alarm system. 

 

The installer should assume the responsibility of developing 
and offering a regular maintenance program to the user as well 
as acquainting the user with the proper operation and limitations 
of the alarm system and its component parts.  Recommendations 
must be included for a specific program of frequent testing (at 
least weekly) to ensure the system’s proper operation at all 
times. 

 

 

REFER TO THE INSTALLATION INSTRUCTIONS FOR 
THE RECEIVER/CONTROL WITH WHICH THIS DEVICE 
IS USED FOR DETAILS REGARDING WARRANTY 
INFORMATION AND LIMITATIONS OF THE ENTIRE 
ALARM SYSTEM.

 

 

 

 

 

 

165 Eileen Way, Syosset, New York 11791 

Copyright © 2000 PITTWAY CORPORATION 

 

¬.99l

K3284V1  11/00 

www.PDF-Zoo.com

firealarmresources.com

Содержание FlexGuard 5852

Страница 1: ... sensitivity Refer to the Adjusting Sensitivity section 3 Enroll the sensor s serial number using the control panel s programming procedure Refer to the Enrolling the 5852 Serial Number section 4 Mount the sensor Refer to the Mounting section 5 Test the sensor Refer to the Testing the 5852 section NOTE The cover tamper switch is activated when the door is open transmitter will send tamper signal t...

Страница 2: ...prior to use in the system The control panel s installation instructions provide detailed programming instructions for enrolling transmitter serial numbers Before programming proceed as follows 1 Install battery if not installed Observe polarity 2 Remove cover assembly 3 When programming the transmitter note the following Input Type 3 Supervised RF Loop Number 1 When prompted transmit from the sen...

Страница 3: ...ed 2 Set glassbreak simulator switches to the TEST and FLEX positions 3 Press the red START button on the simulator The simulator will click on and starts an 8 second armed period 4 Position the simulator near the farthest point of the protected glass and point it directly at the 5852 sensor If window coverings are present close them fully and hold the simulator between the coverings and the prote...

Страница 4: ...1 4 in Coated 2 3 mm 1 8 in 6 4 mm 1 4 in Sealed Insulating 1 3 mm 1 8 in 6 mm 1 4 in Maximum overall 7 16 in Minimum size for all types is 28 cm 11 in square glass must be framed in the wall or mounted in a barrier at least 0 9 m 36 in wide 1 Protected only if both plates of the unit are broken 2 Coated glass with security films including films for solar protection up to 12 mil thick may be used ...